In-plane and out-of-plane needle insertion comparison for a novel lateral block of the radial, ulnar, median and musculocutaneous nerves in cats

被引:6
|
作者
Leung, Jessica B. Y. [1 ,2 ]
Rodrigo-Mocholi, Diego [1 ,3 ]
Martinez-Taboada, Fernando [1 ]
机构
[1] Univ Sydney, Univ Vet Teaching Hosp, Sch Vet Sci, Camperdown, NSW, Australia
[2] Univ Melbourne, Fac Vet & Agr Sci, Werribee, Vic, Australia
[3] Univ London, Anaesthesia Serv, Dept Vet Clin Sci, Royal Vet Coll, Hawkshead Lane, Hatfield, Herts, England
关键词
radial nerve; RUMM block; ulnar nerve; ultrasound-guided block; MID-HUMERAL BLOCK; BRACHIAL-PLEXUS; ULTRASOUND; DOG;
D O I
10.1016/j.vaa.2019.02.006
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To compare two needle insertion techniques in a novel lateral approach to the radial, ulnar, median and musculocutaneous (RUMM) nerve block in cat cadavers. Study design Prospective, cadaveric experimental study. Animals A group of 18 feline cadavers. Methods Cadavers were divided into two groups. Both thoracic limbs of each cat were 'blocked 'using the 'inplane' (IP) or 'out-of-plane' (OP) ultrasound (US)-guided method. A single operator with limited experience performed all the techniques. Cadavers were placed in lateral recumbency and the uppermost limb was injected before turning to 'block' the contralateral limb in the same manner. The IP method consisted of tracking the triceps brachii muscle until the radial (R) nerve could be identified in the same field of view as the ulnar, median and musculocutaneous (UMM) nerve bundle. A needle was guided by US towards the R nerve and subsequently, methylene blue (0.4 mL) was instilled adjacent to it. The needle was retracted and redirected to the UMM nerve bundle, and another 0.4 mL dye was instilled. For the OP technique, the limb was pronated at a 45 degrees angle. The nerves were then identified with the R nerve directly above UMM nerves. A needle was directed OP deep towards UMM nerves and dye (0.4 mL) was instilled. The needle was retracted superficially and 0.4 mL dye instilled next to the R nerve. After dissection, the nerves were assessed and >= 6 mm of staining was considered a successful technique. Results A total of 18 RUMM 'blocks' were performed IP and 18 were performed OP. The IP technique was more successful than the OP technique (R nerve p = 0.0339; UMM nerves p = 0.0352). Conclusions and clinical relevance The lateral approach to the RUMM was achievable in cat cadavers using both needle insertion techniques. The IP technique was significantly more successful than the OP technique.
引用
收藏
页码:523 / 528
页数:6
相关论文
共 50 条
  • [1] Comparison of in-plane and out-of-plane needle insertion with vs. without needle guidance
    Meiser, Verena Constanze
    Kreysa, Helene
    Guntinas-Lichius, Orlando
    Volk, Gerd Fabian
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (09) : 2697 - 2705
  • [2] Comparison of in-plane and out-of-plane needle insertion with vs. without needle guidance
    Verena Constanze Meiser
    Helene Kreysa
    Orlando Guntinas-Lichius
    Gerd Fabian Volk
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 2697 - 2705
  • [3] Incidence of intraneural needle insertion in ultrasound-guided femoral nerve block: A comparison between the out-of-plane versus the in-plane approaches
    Ruiz, A.
    Sala-Blanch, X.
    Martinez-Ocon, J.
    Carretero, M. J.
    Sanchez-Etayo, G.
    Hadzic, A.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2014, 61 (02): : 73 - 77
  • [4] Reflections on: "Comparison of in-plane versus out-of-plane ultrasound-guided radial artery cannulation"
    Sethuraman, Raghuraman
    SRI LANKAN JOURNAL OF ANAESTHESIOLOGY, 2025, 33 (01): : 12 - 13
  • [5] In-plane and out-of-plane spin precession in lateral spin-valves
    Sanchez, J. -C. Rojas
    Laczkowski, P.
    Torres, W. F. Savero
    Cubukcu, M.
    Nguyen, V. D.
    Notin, L.
    Beigne, C.
    Vergnaud, C.
    Marty, A.
    Jamet, M.
    Vila, L.
    Attane, J. P.
    APPLIED PHYSICS LETTERS, 2013, 102 (13)
  • [6] Interfascial plane injection in children - block of median and ulnar nerves at forearm
    Tosetti, Sylvain
    Malenfant, Marie-Pierre
    Desgranges, Francois-Pierrick
    SWISS MEDICAL WEEKLY, 2017, 147 : 12S - 12S
  • [7] Comparison of energy dissipation in the out-of-plane and in-plane fracture of paper
    Tanaka, A
    Kettunen, H
    Niskanen, K
    Keitaanniemi, K
    JOURNAL OF PULP AND PAPER SCIENCE, 2000, 26 (11): : 385 - 390
  • [8] In-Plane and Out-of-Plane Defectivity in Thin Films of Lamellar Block Copolymers
    Mahadevapuram, Nikhila
    Mitra, Indranil
    Bozhchenko, Alona
    Strzalka, Joseph
    Stein, Gila E.
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2016, 54 (02) : 339 - 352
  • [9] Development of a lateral ultrasound-guided approach for the proximal radial, ulnar, median and musculocutaneous (RUMM) nerve block in cats
    Otero, Pablo E.
    Fuensalida, Santiago E.
    Sanchez, Fernanda
    Verdier, Natali
    Tarragona, Lisa
    Briganti, Angela
    Portela, Diego A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2020, 47 (05) : 686 - 693
  • [10] Evaluation of a Novel Out-of-Plane Needle Guide
    Neice, Andrew E.
    Forton, Camelia