No superior performance of hydroxyapatite-coated acetabular cups over porous-coated cups An 8-year follow-up of 81 patients from a previously reported controlled trial

被引:18
|
作者
Valancius, Kestutis [1 ]
Soballe, Kjeld [2 ]
Nielsen, Poul T. [1 ]
Laursen, Mogens B. [1 ]
机构
[1] Aalborg Univ Hosp, Dept Orthopaed Surg, Farsoe Clin Hip & Knee Arthroplasty, Aalborg, Denmark
[2] Aarhus Univ Hosp, Dept Orthopaed Surg, Hip Surg Unit, DK-8000 Aarhus, Denmark
关键词
TOTAL HIP-ARTHROPLASTY; BONE-MINERAL DENSITY; PRESS-FIT; IMPLANTS; PROSTHESES; FIXATION; WEAR; PARTICLES; MIGRATION; SURVIVAL;
D O I
10.3109/17453674.2013.854665
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and purpose Hydroxyapatite (HA) coating is believed to improve bone-implant ingrowth and long-term survival of prostheses. Recent studies, however, have challenged this view. Furthermore, HA particles may produce third-body wear and initiate aseptic loosening of implants. We report the performance of HA-and porous-coated acetabular cups in a prospective randomized trial. Methods This was an 8-year follow-up study of our previously published prospective randomized study to compare clinical outcomes, survival, periprosthetic bone mineral density, migration, and wear rates of HA-and porous-coated acetabular cups. Dual X-ray absorptiometry (DXA) and Ein Bild Roentgen Analyse (EBRA) measurements were used. 100 patients who underwent unilateral cementless total hip arthroplasty were randomized to either porous-coated cups or HA-coated cups. Patients were examined preoperatively and at 3, 6, and 9 months, and also 1, 3, and 8 years after surgery. 81 patients were available for 8-year follow-up, 40 with porous-coated cups and 41 with HA-coated cups. Results Age, sex, bone mineral density, and clinical results (Harris hip score) were similar in the 2 groups. The survival, wear, and migration patterns of the cups were also similar in both groups. The results of periprosthetic bone mineral density scans in region of interest 2 was in favor of the porous-coated cups, but there were no differences between the 2 groups in all the remaining regions of interest. Interpretation HA coating had no statistically significant effect on clinical results, survival, wear, or migration at the 8-year follow-up.
引用
收藏
页码:544 / 548
页数:5
相关论文
共 14 条
  • [1] Failure of hydroxyapatite-coated acetabular cups - Ten-year follow-up of 85 Landos Atoll arthroplasties
    Lai, KA
    Shen, WJ
    Chen, CH
    Yang, CY
    Hu, WP
    Chang, GL
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05): : 641 - 646
  • [2] Hemispheric hydroxyapatite-coated cups with impacted graft for severe bone defects in acetabular reconstruction: ten year follow-up
    Sancho Navarro, Rogelio
    Abat Gonzalez, Ferran
    Crusi Sererols, Xavier
    De Caso Rodriguez, Julio
    Valera Pertegas, Marius
    HIP INTERNATIONAL, 2010, 20 : S106 - S111
  • [3] Porous-coated cementless acetabular cups in revision surgery - A 6-to 11-year follow-up study
    Garcia-Cimbrelo, E
    JOURNAL OF ARTHROPLASTY, 1999, 14 (04): : 397 - 406
  • [4] Outcome of a hemispherical porous-coated acetabular component with a proximally hydroxyapatite-coated anatomical femoral component A 12-TO 15-YEAR FOLLOW-UP STUDY
    Garcia-Rey, E.
    Garcia-Cimbrelo, E.
    Cordero-Ampuero, J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (03): : 327 - 332
  • [5] Porous-coated cups fixed with screws -: A 12-year clinical and radiostereometric follow-up study of 50 hips
    Rohrl, Stephan M.
    Nivbrant, Bo
    Snorrason, Finnur
    Karrholm, Johan
    Nilsson, Kjell G.
    ACTA ORTHOPAEDICA, 2006, 77 (03) : 393 - 401
  • [6] Outcome of a hemispherical porous-coated acetabular component with a proximally hydroxyapatite-coated anatomical femoral component AN UPDATE AT 23 TO 26 YEARS' FOLLOW-UP
    Garcia-Rey, E.
    Carbonell-Escobar, R.
    Cordero-Ampuero, J.
    Garcia-Cimbrelo, E.
    BONE & JOINT JOURNAL, 2019, 101B (04): : 378 - 385
  • [7] A 10-year minimum follow-up of hydroxyapatite-coated threaded cups - Clinical, radiographic and Survivorship analyses with comparison to the literature
    Epinette, JA
    Manley, MT
    D'Antonio, JA
    Edidin, AA
    Capello, WN
    JOURNAL OF ARTHROPLASTY, 2003, 18 (02): : 140 - 148
  • [8] Bone remodelling around HA-coated acetabular cups - A DEXA study with a 3-year follow-up in a randomised trial
    Laursen, M. B.
    Nielsen, P. T.
    Soballe, K.
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (02) : 199 - 204
  • [9] A retrospective clinical and radiographic review of 173 hydroxyapatite-coated screw cups with 5- to 10-year follow-up, showing low revision rates for fixation failure
    Mann, CJ
    McNally, S
    Taylor, E
    Shepperd, JAN
    JOURNAL OF ARTHROPLASTY, 2002, 17 (07): : 851 - 855
  • [10] Minimum 8-year follow-up of revision THA with severe femoral bone defects using extensively porous-coated stems and cortical strut allografts
    Ding, Zi-chuan
    Ling, Ting-xian
    Yuan, Ming-cheng
    Qin, Yong-zhi
    Mou, Ping
    Wang, Hao-yang
    Zhou, Zong-ke
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)