A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise

被引:72
|
作者
Yan, Jianhua [1 ,2 ,3 ]
Schaefferkoetter, Josh [3 ,4 ]
Conti, Maurizio [5 ]
Townsend, David [3 ,4 ]
机构
[1] Shanxi Med Univ, Hosp 1, Dept Nucl Med, 85 Jiefang S Rd, Taiyuan 030001, Shanxi, Peoples R China
[2] Shanxi Med Univ, Mol Imaging Precis Med Collaborat Innovat Ctr, 85 Jiefang S Rd, Taiyuan 030001, Shanxi, Peoples R China
[3] A STAR NUS, Ctr Translat Med, Clin Imaging Res Ctr, 14 Med Dr B1-01, Singapore 17599, Singapore
[4] Natl Univ Singapore Hosp, Dept Diagnost Radiol, Main Bldg 5,Lower Kent Ridge Rd, Singapore 119074, Singapore
[5] Siemens Healthcare Mol Imaging, 810 Innovat Dr, Knoxville, TN 37932 USA
来源
CANCER IMAGING | 2016年 / 16卷
基金
中国国家自然科学基金;
关键词
Low dose; PET/MR; PET/CT; Lung; Image quality; LUNG-CANCER; COMPUTED-TOMOGRAPHY; CT; RECONSTRUCTION; PERFORMANCE; MANAGEMENT; SCANNER;
D O I
10.1186/s40644-016-0086-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Lowering injected dose will have an effect on PET image quality. In this article, we aim to investigate this effect in terms of signal-to-noise ratio (SNR) in the liver, contrast-to-noise ratio (CNR) in the lesion, bias and ensemble image noise. Methods: We present here our method and preliminary results using tuberculosis (TB) cases. Sixteen patients who underwent F-18-FDG PET/MR scans covering the whole lung and portion of the liver were selected for the study. Reduced doses were simulated by randomly discarding events in the PET list mode data stream, and ten realizations at each simulated dose were generated and reconstructed. The volumes of interest (VOI) were delineated on the image reconstructed from the original full statistics data for each patient. Four thresholds (20, 40, 60 and 80 % of SUVmax) were used to quantify the effect of the threshold on CNR at the different count level. Image metrics were calculated for each VOI. This experiment allowed us to quantify the loss of SNR and CNR as a function of the counts in the scan, in turn related to dose injected. Reproducibility of mean and maximum standardized uptake value (SUVmean and SUVmax) measurement in the lesions was studied as standard deviation across 10 realizations. Results: At 5 x 10(6) counts in the scan, the average SNR in the liver in the observed samples is about 3, and the CNR is reduced to 60 % of the full statistics value. The CNR in the lesion and SNR in the liver decreased with reducing count data. The variation of CNR across the four thresholds does not significantly change until the count level of 5 x 106. After correcting the factor related to subject's weight, the square of the SNR in the liver was found to have a very good linear relationship with detected counts. Some quantitative bias appears with count reduction. At the count level of 5 x 10(6), bias and noise in terms of SUVmean and SUVmax are up to 10 and 20 %, respectively. To keep both bias and noise less than 10 %, 5 x 10(6) counts and 20 x 10(6) counts were required for SUVmean and SUVmax, respectively. Conclusions: Initial results with the given data of 16 patients diagnosed as TB demonstrated that 5 x 10(6) counts in the scan could be sufficient to yield good images in terms of SNR, CNR, bias and noise. In the future, more work needs to be done to validate the proposed method with a larger population and lung cancer patient data.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise
    Jianhua Yan
    Josh Schaefferkoetter
    Maurizio Conti
    David Townsend
    Cancer Imaging, 16
  • [2] Erratum to: A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise
    Jianhua Yan
    Josh Schaefferkoetter
    Maurizio Conti
    David Townsend
    Cancer Imaging, 16
  • [3] A method to assess image quality for Low-dose PET: analysis of SNR, CNR, bias and image noise (vol 16, 1, 2016)
    Yan, Jianhua
    Schaefferkoetter, Josh
    Conti, Maurizio
    Townsend, David
    CANCER IMAGING, 2016, 16
  • [4] Image quality evaluation of real low-dose breast PET
    Satoh, Yoko
    Imai, Masamichi
    Ikegawa, Chihiro
    Onishi, Hiroshi
    JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (11) : 1186 - 1193
  • [5] Image quality evaluation of real low-dose breast PET
    Yoko Satoh
    Masamichi Imai
    Chihiro Ikegawa
    Hiroshi Onishi
    Japanese Journal of Radiology, 2022, 40 : 1186 - 1193
  • [6] Effect of acquisition time on image quality in low-dose PET scanning
    Tanaka, A.
    Kubo, N.
    Akagi, H.
    Harada, T.
    Kameya, T.
    Kawai, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S488 - S488
  • [7] Initial assessment of image quality for low-dose PET: evaluation of lesion detectability
    Schaefferkoetter, Joshua D.
    Yan, Jianhua
    Townsend, David W.
    Conti, Maurizio
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14): : 5543 - 5556
  • [8] Investigating low-dose image quality in pediatric TOF-PET/MRI
    Schmall, Jeffrey
    Nevo, Elad
    Edwards, Kevin
    Magee, Ralph
    Servaes, Sabah
    Karp, Joel
    States, Lisa
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [9] Effects on Image Quality From Increasing Noise in Low-Dose CT Perfusion
    Shih, J.
    Liu, Y.
    Herrmann, C.
    Hoelscher, A.
    Raj, A.
    Juluru, K.
    Comunale, J.
    Sanelli, P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [10] Prediction of Standard-Dose PET Image by Low-Dose PET and MRI Images
    Kang, Jiayin
    Gao, Yaozong
    Wu, Yao
    Ma, Guangkai
    Shi, Feng
    Lin, Weili
    Shen, Dinggang
    Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics), 2014, 8679 : 280 - 288