Dose Distribution of 192Ir HDR Brachytherapy Source Measurement using Gafchromic® EBT3 Film Dosimeter and TLD-100H

被引:2
|
作者
Ab Shukor, Nor Shazleen [1 ]
Musarudin, Marianie [1 ]
Abdullah, Reduan [2 ]
Aziz, Mohd Zahri Abdul [3 ]
机构
[1] Univ Sains Malaysia, Sch Hlth Sci, Hlth Campus, Kubang Kerian 16150, Kelantan, Malaysia
[2] Hosp Univ Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia
[3] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Penang, Malaysia
来源
PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY | 2022年 / 30卷 / 01期
关键词
Ir-192 brachytherapy source; dose distribution; Gafchromic (R) EBT3 film dosimeter; Monte Carlo simulation; TLD-100H dosimeter; MONTE-CARLO; WATER PHANTOM; PHOTON; ENERGY;
D O I
10.47836/pjst.30.1.37
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aims to measure the radial dose function and anisotropy function F(r, theta) of High Dose Rate (HDR) Ir-192 source in a fabricated water-equivalent phantom using Gafchromic (R) EBT3 film and TLD-100H and to compare the results obtained with the MCNP5 calculated values. The phantom was fabricated using Perspex PMMA material. For, the EBT3 films with a required dimension and TLD-100H chips were placed at r=1, 2, 3, 5, and 10 cm from the source. The F(r, theta) measurements were carried out at r=1, 2, 3, 5, and 10 cm with the angle range from 10 degrees to 170 degrees. The result of from EBT3 film and TLD-100H was in good agreement (2.10%+/- 1.99). Compared to MCNP5, the differences are within 0.31% to 11.47% for EBT3 film and 0.08% to 10.58% for TLD-100H. For the F(r, theta), an average deviation with the MCNP5 calculation is 4.94%+/- 2.7. For both and F(r, theta), the effects are prominent at r=10 cm. At this distance, the response of both Gafchromic (R) EBT3 film and TLD-100H shows less sensitivity as the dose followed the inverse square law. This work demonstrates that Gafchromic (R) EBT3 film dosimeter and TLD-100H are suitable dosimeters in 192Ir dosimetric measurements at a radial distance of <5 cm.
引用
收藏
页码:691 / 708
页数:18
相关论文
共 41 条
  • [1] Experimental determination of Gd dose enhancement and Gd dose sparing by 192Ir brachytherapy source with Gafchromic EBT3 dosimeter
    Santibanez, M.
    Fuentealba, M.
    APPLIED RADIATION AND ISOTOPES, 2021, 175
  • [2] Dosimetry evaluation of 192Ir Flexisource using gafchromic EBT3 film
    Oustous, Aziz
    Airouss, Zouhair
    EL Attaoui, Yacine
    Oustous, Yassine
    Khalis, Mohammed
    Sebihi, Rajaa
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [3] Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source
    Ayoobian, Navid
    Asl, Akbar Sarabi
    Poorbaygi, Hosein
    Javanshir, Mohammad Reza
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 194 - 205
  • [4] Characterisation of delaminated GAFCHROMIC™ EBT3 films in clinical photon, proton and 192Ir brachytherapy source
    Tagiling, N.
    Ab Rashid, R.
    Abdullah, R.
    Dollah, N.
    Geso, M.
    Tominaga, T.
    Akasaka, H.
    Kie, K.
    Rahman, W. N.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [5] Dose Calibration of Gafchromic EBT3 Film for Ir-192 Brachytherapy Source Using 3D-Printed ABS Plastic
    Oare, C.
    Ehler, E.
    Sterling, D.
    Mathew, D.
    Wilke, C.
    Ferreira, C.
    MEDICAL PHYSICS, 2018, 45 (06) : E595 - E595
  • [6] Gadolinium dose enhancement determination by unlaminated EBT3 films irradiated with 192Ir brachytherapy source
    Fuentealba, M.
    Santibanez, M.
    Bodineau, C.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [7] Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics
    Oare, Courtney
    Wilke, Christopher
    Ehler, Eric
    Mathew, Damien
    Sterling, David
    Ferreira, Clara
    3D PRINTING IN MEDICINE, 2019, 5 (01)
  • [8] Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics
    Courtney Oare
    Christopher Wilke
    Eric Ehler
    Damien Mathew
    David Sterling
    Clara Ferreira
    3D Printing in Medicine, 5
  • [9] HDR Brachytherapy dosimetry: clinical use of micro-silica bead TLD & Gafchromic EBT3 film
    Douralis, A.
    Jafari, S. M.
    Polak, W.
    Palmer, A. L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : E572 - E573
  • [10] A dosimetry method in the transverse plane of HDR Ir-192 brachytherapy source using gafchromic EBT2 film
    Uniyal, S. C.
    Sharma, S. D.
    Naithani, U. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 129 - 133