Influence of MRI-based bone outline definition errors on external radiotherapy dose calculation accuracy in heterogeneous pseudo-CT images of prostate cancer patients

被引:17
|
作者
Korhonen, Juha [1 ,2 ]
Kapanen, Mika [1 ,2 ,3 ]
Keyrilainen, Jani [2 ]
Seppala, Tiina [2 ]
Tuomikoski, Laura [2 ]
Tenhunen, Mikko [2 ]
机构
[1] Helsinki Univ Cent Hosp Ltd, Clin Res Inst, Helsinki 00029, Finland
[2] Univ Helsinki, Cent Hosp, HUCH Canc Ctr, Helsinki, Finland
[3] Tampere Univ Hosp, Dept Med Phys, Tampere, Finland
关键词
MAGNETIC-SUSCEPTIBILITY; ATTENUATION CORRECTION; DISTORTION; SIMULATION;
D O I
10.3109/0284186X.2014.929737
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. This work evaluates influences of susceptibility-induced bone outline shift and perturbations, and bone segmentation errors on external radiotherapy dose calculation accuracy in magnetic resonance imaging (MRI)-based pseudo-computed tomography (CT) images of the male pelvis. Material and methods. T-1/T-2*-weighted fast gradient echo, T-1-weighted spin echo and T-2-weighted fast spin echo images were used in bone detection investigation. Bone edge location and bone diameter in MRI were evaluated by comparing those in the images with actual physical measurements of fresh deer bones positioned in a gelatine phantom. Dose calculation accuracy in pseudo-CT images was investigated for 15 prostate cancer patients. Bone outlines in T-1/T-2*-weighted images were contoured and additional segmentation errors were simulated by expanding and contracting the bone contours with 1 mm spacing. Heterogeneous pseudo-CT images were constructed by adopting a technique transforming the MRI intensity values into Hounsfield units with separate conversion models within and outside of bone segment. Results. Bone edges and diameter in the phantom were illustrated correctly within a 1 mm-pixel size in MRI. Each 1 mm-sized systematic error in bone segment resulted in roughly 0.4% change to the prostate dose level in the pseudo-CT images. The prostate average (range) dose levels in pseudo-CT images with additional systematic bone segmentation errors of -2 mm, 0 mm and 2 mm were 0.5% (-0.5-1.4%), -0.2% (-1.0-0.7%), and -0.9% (-1.8-0.0%) compared to those in CT images, respectively, in volumetric modulated arc therapy treatment plans calculated by Monte Carlo algorithm. Conclusions. Susceptibility-induced bone outline shift and perturbations do not result in substantial uncertainty for MRI-based dose calculation. Dose consistency of 2% can be achieved reliably for the prostate if heterogeneous pseudo-CT images are constructed with <=+/- 2 mm systematic error in bone segment.
引用
收藏
页码:1100 / 1106
页数:7
相关论文
共 6 条
  • [1] Comparison of Deep Learning-Based and Patch-Based Methods for Pseudo-CT Generation in MRI-Based Prostate Dose Planning
    Largent, Axel
    Barateau, Anais
    Nunes, Jean-Claude
    Mylona, Eugenia
    Castelli, Joel
    Lafond, Caroline
    Greer, Peter B.
    Dowling, Jason A.
    Baxter, John
    Saint-Jalmes, Herve
    Acosta, Oscar
    de Crevoisier, Renaud
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (05): : 1137 - 1150
  • [2] Influence of organ at risk definition on rectal dose-volume histograms in patients with prostate cancer undergoing external-beam radiotherapy
    Boehmer, D
    Kuczer, D
    Badakhshi, H
    Stiefel, S
    Kuschke, W
    Wernecke, KD
    Budach, V
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 (05) : 277 - 282
  • [3] Enhancing U-Net-based Pseudo-CT generation from MRI using CT-guided bone segmentation for radiation treatment planning in head & neck cancer patients
    Yawson, Ama Katseena
    Sallem, Habiba
    Seidensaal, Katharina
    Welzel, Thomas
    Klueter, Sebastian
    Paul, Katharina Maria
    Dorsch, Stefan
    Beyer, Cedric
    Debus, Juergen
    Jaekel, Oliver
    Bauer, Julia
    Giske, Kristina
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04):
  • [4] Accuracy of dose calculation based on artefact corrected Cone Beam CT images of lung cancer patients (vol 1, pg 6, 2017)
    van den Bosch, M.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 13 : 29 - 29
  • [5] Various approaches for pseudo-CT scan creation based on ultrasound to ultrasound deformable image registration between different treatment time points for radiotherapy treatment plan adaptation in prostate cancer patients
    Camps, Saskia
    van der Meer, Skadi
    Verhaegen, Frank
    Fontanarosa, Davide
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (03):
  • [6] Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning
    de Boer, HCJ
    De Koste, JRV
    Senan, S
    Visser, AG
    Heijmen, BJM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 857 - 868