Optimization of noninvasive activation studies with O-15-water and three-dimensional positron emission tomography

被引:0
|
作者
Sadato, N
Carson, RE
DaubeWitherspoon, ME
Campbell, G
Hallett, M
Herscovitch, P
机构
[1] NIH, PET DEPT, WARREN GRANT MAGNUSON CLIN CTR, BETHESDA, MD 20892 USA
[2] NINCDS, HUMAN MOTOR CONTROL SECT, MED NEUROL BRANCH, BETHESDA, MD 20892 USA
[3] NINCDS, BIOMETRY & FIELD STUDIES BRANCH, BETHESDA, MD 20892 USA
来源
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM | 1997年 / 17卷 / 07期
关键词
positron emission tomography; activation study; optimum dose; signal-to-noise ratio;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the effects of varying the injected dose, speed of injection, and scan duration to maximize the sensitivity of noninvasive activation studies with O-15-water and three-dimensional positron emission tomography. A covert word generation task was used in four subjects with bolus injections of 2.5 to 30 mCi of O-15-water. The noise equivalent counts (NEC) for the whole brain peaked at an injected dose of 12 to 15 mCi. This was lower than expected from phantom studies, presumably because of the effect of radioactivity outside of the brain. A 10 mCi injection gave an NEC of 92.4 +/- 2.2% of the peak value. As the scan duration increased from 60 to 90 to 120 seconds, the areas of activation decreased in size or were no longer detected. Therefore, we selected a 1 minute scan using 10 mCi for bolus injections. We then performed simulation studies to evaluate, for a given CBF change, the effect on signal-to-noise ratio (S/N) of longer scan duration with slow tracer infusions. Using a measured arterial input function from a bolus injection, new input functions for longer duration injections and the corresponding tissue data were simulated, Combining information about image noise derived from Hoffman brain phantom studies with the simulated tissue data allowed calculation of the SM for a given CBF change. The simulation shows that a slow infusion permits longer scan acquisitions with only a small loss in S/N. This allows the investigator to choose the injection duration, and thus the time period during which scan values are sensitive to regional CBF.
引用
收藏
页码:732 / 739
页数:8
相关论文
共 50 条
  • [1] Experimental studies of liver perfusion using O-15-water and positron emission tomography (PET).
    Strauss, LG
    Haberkorn, U
    Schosser, R
    Ziegler, SI
    DimitrakopoulouStrauss, A
    Oberdorfer, F
    vanKaick, G
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 647 - 647
  • [2] PRESURGICAL FUNCTIONAL BRAIN MAPPING IN CHILDREN BY MEANS OF O-15-WATER POSITRON EMISSION TOMOGRAPHY
    MUELLER, RA
    CHUGANI, HT
    MUZIK, O
    ROTHERMEL, RD
    NIGRO, MA
    MANGNER, TJ
    CHAKRABORTY, PK
    NEUROLOGY, 1995, 45 (04) : A295 - A296
  • [3] Bolus injection versus slow infusion of [15O]water for positron emission tomography activation studies
    Beason-Held, LL
    Desmond, RE
    Herscovitch, P
    Carson, RE
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (08): : 843 - 852
  • [4] IDENTIFICATION OF VIABLE MYOCARDIUM IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE USING O-15-WATER AND POSITRON EMISSION TOMOGRAPHY
    IIDA, H
    TAKAHASHI, A
    AGOSTINI, D
    TAMURA, Y
    ONO, Y
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P24 - P24
  • [5] A NEW STRATEGY FOR THE ASSESSMENT OF VIABLE MYOCARDIUM AND REGIONAL MYOCARDIAL BLOOD-FLOW USING O-15-WATER AND DYNAMIC POSITRON EMISSION TOMOGRAPHY
    YAMAMOTO, Y
    DESILVA, R
    RHODES, CG
    ARAUJO, LI
    IIDA, H
    RECHAVIA, E
    NIHOYANNOPOULOS, P
    HACKETT, D
    GALASSI, AR
    TAYLOR, CJV
    LAMMERTSMA, AA
    JONES, T
    MASERI, A
    CIRCULATION, 1992, 86 (01) : 167 - 178
  • [6] Fourier approaches for fully three-dimensional reconstruction in positron emission tomography
    Matej, S
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, PROCEEDINGS, 2002, : 245 - 251
  • [7] O-15-butanol is superior to O-15-water in detecting visual activation
    Kemna, L
    Herzog, H
    NEUROIMAGE, 2001, 13 (06) : S21 - S21
  • [8] O-15-butanol and O-15-water compared in rCBF-studies on motor activation in individual patients
    Herzog, H
    Seitz, RJ
    Tellmann, L
    MullerGartner, HW
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 992 - 992
  • [9] Butanol is superior to water for performing positron emission tomography activation studies
    Votaw, JR
    Henry, TR
    Shoup, TM
    Hoffman, JM
    Woodard, JL
    Goodman, MM
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1999, 19 (09): : 982 - 989
  • [10] Production, automatic delivery and bolus injection of [O-15]water for positron emission tomography studies
    VanNaemen, J
    Monclus, M
    Damhaut, P
    Luxen, A
    Goldman, S
    NUCLEAR MEDICINE AND BIOLOGY, 1996, 23 (04): : 413 - 416