Supply System Based on the 18-pulse Diode Rectifier with Coupled Reactors and Integrated with the Series Active Power Filter

被引:0
|
作者
Mysiak, P. [1 ]
Strzelecki, R. [1 ]
Tunia, H. [2 ]
Zymmer, K. [3 ]
机构
[1] Gdynia Maritime Univ, Fac Elect Engn, Dept Ship Automat, 81-87 Morska Str, PL-81225 Gdynia, Poland
[2] Kielce Univ Technol, Fac Elect Engn Automat & Comp Sci, Chair Power Engn Elect, PL-25314 Kielce, Poland
[3] Electrotech Inst, Dept Power Converters, PL-04703 Warsaw, Poland
关键词
Active filters; multi-pulse converters; coupled reactors; power conditioning; AC-DC CONVERTER; MITIGATION; QUALITY;
D O I
10.1109/CPE.2011.5942275
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse converter system with direct voltage output, cooperating with a small series active power filter (S-APF). The presented system makes it possible to reduce, especially in autonomous supply networks, undesired higher harmonics in the network current. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network reactors (CDT and CTR). Simultaneous use of the magnetically coupled reactors and the small active power filter provides opportunities for easy and cheap reduction of the supply current THD coefficient, down to the values acceptable by clean power converters (CPC) conditions.
引用
收藏
页码:442 / 451
页数:10
相关论文
共 50 条
  • [1] A Hybrid, Coupled Reactors based 18-Pulse Diode Rectifier with Active Power Filter
    Strzelecki, Ryszard
    Mysiak, Piotr
    2014 IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS), 2014, : 94 - 101
  • [2] A robust 18-pulse, diode rectifier with coupled reactors
    Mysiak, P.
    Strzelecki, R.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2011, 59 (04) : 541 - 550
  • [3] Suppression of Supply Current Harmonics of 18-Pulse Diode Rectifier by Series Active Power Filter with LC Coupling
    Sleszynski, Wojciech
    Cichowski, Artur
    Mysiak, Piotr
    ENERGIES, 2020, 13 (22)
  • [4] Current harmonic controller in multiple reference frames for series active power filter integrated with 18-pulse diode rectifier
    Sleszynski, W.
    Cichowski, A.
    Mysiak, P.
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2018, 66 (05) : 699 - 704
  • [5] Experimental Test Results of the 150kVA 18-Pulse Diode Rectifier with Series Active Power Filter
    Mysiak, Piotr
    Sleszynski, Wojciech
    Cichowski, Artur
    2016 10TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG), 2016, : 380 - 383
  • [6] Engineering Application Research of Aircraft Power Supply Characteristics Based on 18-Pulse Rectifier Power System
    Zhang, Yingying
    Zhang, Xiaoli
    Chen, Zhiwei
    Li, Bing
    He, Yigang
    IEEE ACCESS, 2019, 7 : 22026 - 22034
  • [7] Application of Low Harmonic 18-Pulse Rectifier Power Supply for Radar Power System
    Zhang, Yingying
    Chen, Zhiwei
    Li, Bing
    He, Yigang
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (02) : 1080 - 1088
  • [8] Modeling and Prediction of the Reliability Analysis of an 18-Pulse Rectifier Power Supply for Aircraft Based Applications
    Zhang, Yingying
    Xia, Jinsong
    Zhang, Xiaoli
    Chen, Zhiwei
    Li, Bing
    Luo, Qiwu
    He, Yigang
    IEEE ACCESS, 2020, 8 : 47063 - 47071
  • [9] Current regulation for a series active filter integrated with a diode rectifier
    le Roux, AD
    Mouton, HD
    Akagi, H
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1026 - 1031
  • [10] DFT-Based Repetitive Control of a Series Active Filter Integrated With a 12-Pulse Diode Rectifier
    le Roux, Abraham D.
    Mouton, Hendrik du T.
    Akagi, Hirofumi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1515 - 1521