Purpose: This study evaluated the deformation of a metallic framework connected to 15 stone casts fabricated using 3 transfer techniques to determine the most accurate impression procedure. Materials and Methods: Five stone casts were made from polyether impressions of an epoxy resin master model for each transfer technique. Group 1 samples were created by the direct splinted technique (square transfer copings splinted with carbon steel pins and autopolymerizing acrylic resin, custom tray); group 2 samples were made by the direct nonsplinted technique (square transfer copings, custom tray); and group 3 samples were fabricated using the indirect technique (tapered transfer copings, custom tray). Sixteen strain gauges were fixed on the framework to measure the degree of framework deformation for each stone cast. Pairs of strain gauges placed opposite each other constituted 1 channel to read deformation (half Wheatstone bridge). Deformation readings were collected at the 4 segments between abutments in 4 directions (anterior, posterior, superior, and inferior). Deformation data were analyzed using analysis of variance and the Tukey test at the .05 and .01 levels of significance. Results: Group 1 samples allowed the most accurate reproduction of analog position compared to the samples made using the other techniques. No significant difference was found between the direct nonsplinted (group 2) and indirect (group 3) techniques. Discussion: Although some studies have evaluated transfer techniques with similar methodology, this study demonstrated the most suitable strain gauge setup to record framework deformations in all directions and simultaneously offset the effects of temperature variation. Conclusions: The direct splinted technique was the most accurate transfer method for multiple abutments compared to direct nonsplinted and indirect techniques.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 50 条
  • [1] In vitro evaluation of three transfer techniques precision for implant-supported prosthesis of multiple abutments.
    Naconecy, MM
    Teixeira, ER
    Frasca, LCF
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 216 - 216
  • [2] Strain Gauge Evaluation of Transfer Impression Techniques of Multiple Implant-Supported Prosthesis
    Nishioka, Renato Sussumu
    De Santis, Leandro Ruivo
    De Melo Nishioka, Gabriela Nogueira
    Kojima, Alberto Noriyuki
    Souza, Francisley Avila
    IMPLANT DENTISTRY, 2018, 27 (02) : 188 - 192
  • [3] In vitro evaluation of the precision of working casts for implant-supported restoration with multiple abutments
    Castilho, Anderson Almeida
    Kojima, Alberto Noriyuki
    Braga Pereira, Sarina Maciel
    de Vasconcellos, Diego Klee
    Itinoche, Marcos Koiti
    Faria, Renata
    Bottino, Marco Antonio
    JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (03) : 241 - 246
  • [4] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [5] The use of healing abutments for the fabrication of cement-retained, implant-supported provisional prostheses
    Proussaefs, P
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (03): : 333 - 335
  • [6] Evaluation of Marginal Misfit of Implant-Supported Fixed Prostheses Made Using Different Techniques
    de Luna Gomes, Jessica Marcela
    Dantas de Moraes, Sandra Lucia
    Santiago Junior, Joel Ferreira
    Araujo Lemos, Cleidiel Aparecido
    Grossi, Marcio Lima
    Pellizzer, Eduardo Piza
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (04) : 345 - 348
  • [7] The role of welding techniques in the biomechanical behavior of implant-supported prostheses
    Rodrigues, Sabrina Alessandra
    Camacho Presotto, Anna Gabriella
    Ricardo Barao, Valentim Adelino
    Xediek Consani, Rafael Leonardo
    Arruda Nobilo, Mauro Antonio
    Mesquita, Marcelo Ferraz
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 78 : 435 - 442
  • [8] EFFECT OF CANTILEVER LENGTH ON STRESS TRANSFER BY IMPLANT-SUPPORTED PROSTHESES
    WHITE, SN
    CAPUTO, AA
    ANDERKVIST, T
    JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (05): : 493 - 499
  • [9] Accuracy of impression and pouring techniques for an implant-supported prosthesis
    Del'Acqua, Marcelo Antonialli
    Arioli-Filho, Joao Neudenir
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (02) : 226 - 236
  • [10] Accuracy of different digital scanning techniques and scan bodies for complete-arch implant-supported prostheses
    Mizumoto, Ryan M.
    Yilmaz, Burak
    McGlumphy, Edwin A., Jr.
    Seidt, Jeremy
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (01): : 96 - 104