Glucose Sensing in the Subcutaneous Tissue: Attempting to Correlate the Immune Response with Continuous Glucose Monitoring Accuracy

被引:9
|
作者
Joseph, Jeffrey I. [1 ]
Eisler, Gabriella [1 ]
Diaz, David [1 ]
Khalf, Abdurizzagh [1 ]
Loeum, Channy [1 ]
Torjman, Marc C. [1 ]
机构
[1] Thomas Jefferson Univ, Sidney Kimmel Med Coll, Jefferson Artificial Pancreas Ctr, Dept Anesthesiol, Jefferson Alumni Hall 565,1020 Locust St, Philadelphia, PA 19107 USA
关键词
IMPLANTS; MEMBRANES; SYSTEM; IMPACT; CELLS;
D O I
10.1089/dia.2018.0106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:321 / 324
页数:4
相关论文
共 50 条
  • [1] A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE
    Huang, X.
    Li, S.
    Schultz, J.
    Wang, Q.
    Lin, Q.
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 352 - 355
  • [2] Accuracy of continuous subcutaneous glucose monitoring in detecting hypoglycemia in diabetic patients
    Maran, A
    Crepaldi, C
    Ninkovic, S
    Avogaro, A
    Varalli, M
    Poscia, A
    Tiengo, A
    DIABETES, 2002, 51 : A124 - A124
  • [3] Accuracy of a subcutaneous continuous glucose monitoring system in critically ill patients
    Rijkenberg, S.
    van Steen, S. C. J.
    DeVries, J. H.
    van der Voort, P. H. J.
    DIABETOLOGIA, 2016, 59 : S412 - S413
  • [4] SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING: A COMPARISON
    Albuquerque, Andrea
    NURSING IN CRITICAL CARE, 2021, 26 : 29 - 29
  • [5] CONTINUOUS GLUCOSE MONITORING IN SUBCUTANEOUS TISSUE AND BLOOD WITH AN AMPEROMETRIC ENZYME ELECTRODE
    BRUCKEL, J
    ZIER, H
    KERNER, W
    PFEIFFER, EF
    BIOSENSORS : APPLICATIONS IN MEDICINE, ENVIRONMENTAL PROTECTION AND PROCESS CONTROL, 1989, 13 : 89 - 91
  • [6] Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients
    Rijkenberg, S.
    van Steen, S. C.
    DeVries, J. H.
    van der Voort, P. H. J.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 953 - 964
  • [7] Accuracy and reliability of a subcutaneous continuous glucose monitoring device in critically ill patients
    S. Rijkenberg
    S. C. van Steen
    J. H. DeVries
    P. H. J. van der Voort
    Journal of Clinical Monitoring and Computing, 2018, 32 : 953 - 964
  • [8] Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    Ulrike Holzinger
    Joanna Warszawska
    Reinhard Kitzberger
    Harald Herkner
    Philipp G. H. Metnitz
    Christian Madl
    Intensive Care Medicine, 2009, 35 : 1383 - 1389
  • [9] Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    Holzinger, Ulrike
    Warszawska, Joanna
    Kitzberger, Reinhard
    Herkner, Harald
    Metnitz, Philipp G. H.
    Madl, Christian
    INTENSIVE CARE MEDICINE, 2009, 35 (08) : 1383 - 1389
  • [10] COMMENTS ON SUBCUTANEOUS GLUCOSE MONITORING - RESPONSE
    REACH, G
    POITOUT, V
    DIABETOLOGIA, 1994, 37 (05) : 541 - 542