Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging

被引:18
|
作者
Othman, Ahmed E. [1 ,2 ]
Brockmann, Carolin [1 ]
Yang, Zepa [3 ,4 ]
Kim, Changwon [3 ,4 ]
Afat, Saif [1 ]
Pjontek, Rastislav [1 ]
Nikoubashman, Omid [1 ]
Brockmann, Marc A. [1 ]
Nikolaou, Konstantin [2 ]
Wiesmann, Martin [1 ]
Kim, Jong Hyo [3 ,4 ,5 ,6 ]
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost & Intervent Neuroradiol, D-52074 Aachen, Germany
[2] Univ Tubingen, Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Suwon 433270, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[5] Adv Inst Convergence Technol, Ctr Med IT Convergence Technol Res, Suwon 433270, South Korea
[6] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
关键词
Stroke; Computed tomography; Perfusion imaging; Radiation dosage; Brain ischemia; ANEURYSMAL SUBARACHNOID HEMORRHAGE; DELAYED CEREBRAL-ISCHEMIA; ACUTE STROKE; BLOOD-FLOW; REDUCTION; BRAIN; ACCURACY;
D O I
10.1007/s00330-015-3853-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To examine the impact of denoising on ultra-low-dose volume perfusion CT (ULD-VPCT) imaging in acute stroke. Simulated ULD-VPCT data sets at 20 % dose rate were generated from perfusion data sets of 20 patients with suspected ischemic stroke acquired at 80 kVp/180 mAs. Four data sets were generated from each ULD-VPCT data set: not-denoised (ND); denoised using spatiotemporal filter (D1); denoised using quanta-stream diffusion technique (D2); combination of both methods (D1 + D2). Signal-to-noise ratio (SNR) was measured in the resulting 100 data sets. Image quality, presence/absence of ischemic lesions, CBV and CBF scores according to a modified ASPECTS score were assessed by two blinded readers. SNR and qualitative scores were highest for D1 + D2 and lowest for ND (all p a parts per thousand currency signaEuro parts per thousand 0.001). In 25 % of the patients, ND maps were not assessable and therefore excluded from further analyses. Compared to original data sets, in D2 and D1 + D2, readers correctly identified all patients with ischemic lesions (sensitivity 1.0, kappa 1.0). Lesion size was most accurately estimated for D1 + D2 with a sensitivity of 1.0 (CBV) and 0.94 (CBF) and an inter-rater agreement of 1.0 and 0.92, respectively. An appropriate combination of denoising techniques applied in ULD-VPCT produces diagnostically sufficient perfusion maps at substantially reduced dose rates as low as 20 % of the normal scan. aEuro cent Perfusion-CT is an accurate tool for the detection of brain ischemias. aEuro cent The high associated radiation doses are a major drawback of brain perfusion CT. aEuro cent Decreasing tube current in perfusion CT increases image noise and deteriorates image quality. aEuro cent Combination of different image-denoising techniques produces sufficient image quality from ultra-low-dose perfusion CT.
引用
收藏
页码:167 / 174
页数:8
相关论文
共 50 条
  • [1] Impact of image denoising on image quality, quantitative parameters and sensitivity of ultra-low-dose volume perfusion CT imaging
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikoubashman
    Marc A. Brockmann
    Konstantin Nikolaou
    Martin Wiesmann
    Jong Hyo Kim
    European Radiology, 2016, 26 : 167 - 174
  • [2] Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters
    Ping Li
    Wanling Deng
    Huadan Xue
    Kai Xu
    Liang Zhu
    Juan Li
    Zhaoyong Sun
    Zhengyu Jin
    Abdominal Radiology, 2019, 44 : 2196 - 2204
  • [3] Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters
    Li, Ping
    Deng, Wanling
    Xue, Huadan
    Xu, Kai
    Zhu, Liang
    Li, Juan
    Sun, Zhaoyong
    Jin, Zhengyu
    ABDOMINAL RADIOLOGY, 2019, 44 (06) : 2196 - 2204
  • [4] Impact of Morphotype on Image Quality and Diagnostic Performance of Ultra-Low-Dose Chest CT
    Ortlieb, Anne-Claire
    Labani, Aissam
    Severac, Francois
    Jeung, Mi-Young
    Roy, Catherine
    Ohana, Mickael
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [5] Evaluation of the Image Quality of Ultra-Low-Dose Paranasal Sinus CT
    Aksamoglu, Melih
    Menzilcioglu, Mehmet Sait
    EUROPEAN JOURNAL OF THERAPEUTICS, 2023, 29 (02): : 143 - 148
  • [6] Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT
    Xu, Yan
    He, Wen
    Chen, Hui
    Hu, Zhihai
    Li, Juan
    Zhang, Tingting
    CLINICAL RADIOLOGY, 2013, 68 (09) : 902 - 908
  • [7] Ultra-Low-Dose Sparse-View Quantitative CT Liver Perfusion Imaging
    Enjilela, Esmaeil
    Lee, Ting-Yim
    Hsieh, Jiang
    Murjoomdar, Amol
    Stewart, Errol
    Dekaban, Mark
    Su, Feng
    So, Aaron
    TOMOGRAPHY, 2017, 3 (04) : 175 - 179
  • [8] Ultra-low-dose CT of the Lung: Effect of Iterative Reconstruction Techniques on Image Quality
    Yanagawa, Masahiro
    Gyobu, Tomoko
    Leung, Ann N.
    Kawai, Misa
    Kawata, Yutaka
    Sumikawa, Hiromitsu
    Honda, Osamu
    Tomiyama, Noriyuki
    ACADEMIC RADIOLOGY, 2014, 21 (06) : 695 - 703
  • [9] Patient-specific image denoising for ultra-low-dose CT-guided lung biopsies
    Green, Michael
    Marom, Edith M.
    Konen, Eli
    Kiryati, Nahum
    Mayer, Arnaldo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2017, 12 (12) : 2145 - 2155
  • [10] Improved image quality in ultra-low-dose multiple detector spiral CT of the chest
    Schütz, A
    Kolokythas, O
    Wisianowsky, C
    Nitsch, C
    Sokiranski, R
    Brambs, HJ
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 75 - 77