Portable pneumatic biventricular driver for the thoratec ventricular assist device

被引:0
|
作者
Farrar, DJ
Buck, KE
Coulter, JH
Kupa, EJ
机构
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
As patients with left ventricular (LVAD) and biventricular assist devices are supported for increasingly long durations while awaiting heart transplantation or cardiac recovery, there is a need to facilitate greater patient mobility and ambulation. To meet these needs, the authors have developed the Thoratec TLC-II Portable VAD Driver, which is a small briefcase sized (33 x 34 x 13 cm) pneumatic unit for Thoratec's paracorporeal and implantable VADs. The TLC-II consists of an electric motor driven air compressor for supplying bath positive and negative air pressure, solenoid valves for switching between LVAD/RVAD filling and ejection, and microcontroller based electronics and firmware. Four power sources are provided: external power, two rechargeable lithium-ion battery packs, and an emergency battery that drives an independent electronic back-up system. The 8 kg TLC-II can be carried by hand, with a shoulder strap, or pushed on a wheeled mobility cart. Trend information stored in the TLC-II can be accessed by an external system computer with a color touchscreen mounted on a docking station, which also houses the battery charger. Control configurations (univentricular/biventricular operation, beat rates, etc.) are entered on the touchscreen and programmed into the TLC-II. In vitro testing demonstrates the ability to pump VAD outputs up to 7 L/min. By providing improved patient mobility, this small driver will enhance rehabilitation and improve the quality of life of VAD patients.
引用
收藏
页码:M631 / M634
页数:4
相关论文
共 50 条
  • [1] Biventricular cannulation for the Thoratec ventricular assist device
    Arabía, FA
    Paramesh, V
    Toporoff, B
    Arzouman, DA
    Sethi, GK
    Copeland, JG
    ANNALS OF THORACIC SURGERY, 1998, 66 (06): : 2119 - 2120
  • [2] Development of a compact portable driver for a pneumatic ventricular assist device
    Tomohiro Nishinaka
    Yoshiyuki Taenaka
    Eisuke Tatsumi
    Hiroyuki Ohnishi
    Akihiko Homma
    Kyoko Shioya
    Toshihide Mizuno
    Tomonori Tsukiya
    Sadahiko Mushika
    Yasuhiro Hashiguchi
    Akira Suzuki
    Soichiro Kitamura
    Journal of Artificial Organs, 2007, 10 : 236 - 239
  • [3] Development of a compact portable driver for a pneumatic ventricular assist device
    Nishinaka, Tomohiro
    Taenaka, Yoshiyuki
    Tatsumi, Eisuke
    Ohnishi, Hiroyuki
    Homma, Akihiko
    Shioya, Kyoko
    Mizuno, Toshihide
    Tsukiya, Tomonori
    Mushika, Sadahiko
    Hashiguchi, Yasuhiro
    Suzuki, Akira
    Kitamura, Soichiro
    JOURNAL OF ARTIFICIAL ORGANS, 2007, 10 (04) : 236 - 239
  • [4] Development of an intracorporeal Thoratec ventricular assist device for univentricular or biventricular support
    Farrar, DJ
    Reichenbach, SH
    Rossi, SA
    Weidman, JR
    ASAIO JOURNAL, 2000, 46 (03) : 351 - 353
  • [5] The Thoratec® ventricular assist device system
    Whittaker, S
    Glanville, C
    PERFUSION-UK, 2000, 15 (04): : 363 - 368
  • [6] Bridge to Recovery With a Thoratec Biventricular Assist Device for Postpartum Cardiomyopathy
    Zimmerman, Hannah
    Coelho-Anderson, Romana
    Smith, Richard
    Nolan, Paul
    Copeland, Jack
    ASAIO JOURNAL, 2010, 56 (05) : 479 - 480
  • [7] Thoratec paracorporeal biventricular assist device therapy: the Freiburg experience
    Brehm, Kerstin
    Heilmann, Claudia
    Siepe, Matthias
    Benk, Christoph
    Beyersdorf, Friedhelm
    Schlensak, Christian
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (01) : 207 - 212
  • [8] Transesophageal echocardiography diagnosis of extracardiac left ventricular assist device inflow cannula obstruction in a patient with thoratec intracorporeal ventricular assist device biventricular support
    Frogel, Jonathan
    Vodur, Srilatha
    Horak, Jiri
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (06) : 777.e5 - 777.e6
  • [9] A PORTABLE PNEUMATIC DRIVING UNIT FOR A LEFT-VENTRICULAR ASSIST DEVICE
    KABEI, N
    SHIMEMURA, E
    SAKURAI, Y
    TSUCHIYA, K
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1988, 11 (03): : 186 - 190
  • [10] A PORTABLE PNEUMATIC DRIVING UNIT FOR A LEFT-VENTRICULAR ASSIST DEVICE
    KABEI, N
    SHIMEMURA, E
    SAKURAI, Y
    TSUCHIYA, K
    ARTIFICIAL ORGANS, 1987, 11 (04) : 327 - 327