Influence of Workstation screen for indoor mechanical ventilation

被引:0
|
作者
Li Yunjiang [1 ]
Yung Yanan [1 ]
机构
[1] China Three Gorges Univ, Coll Civil Engn & Architecture, Yichang 443002, Peoples R China
关键词
Office building; mechanical ventilation; screens PMV;
D O I
10.4028/www.scientific.net/AMM.405-408.2959
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper uses the PHOENICS software to discusses a screen set mode's influence on the indoor mechanical ventilation, then calculated face wind speed, air temperature, air age and PMV. And analyzes the comparison of data, therefore concluded a reasonable way of setting screen in the office building.
引用
收藏
页码:2959 / 2963
页数:5
相关论文
共 50 条
  • [1] Influence of mechanical ventilation systems on indoor VOC concentrations in residential buildings
    Park, Sangin
    Kagi, Naoki
    Umishio, Wataru
    Shinohara, Naohide
    Kim, Hoon
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2025,
  • [2] Influence of mechanical ventilation system on indoor carbon dioxide and particulate matter concentration
    Yu, Conson K. H.
    Li, Min
    Chan, Vincent
    Lai, Alvin C. K.
    BUILDING AND ENVIRONMENT, 2014, 76 : 73 - 80
  • [3] Influence of an insect screen on greenhouse ventilation
    Kittas, C
    Boulard, T
    Bartzanas, T
    Katsoulas, N
    Mermier, M
    TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 1083 - 1090
  • [4] Influence of ventilation on indoor radon level
    Chao, CYH
    Tung, TCW
    Burnett, J
    BUILDING AND ENVIRONMENT, 1997, 32 (06) : 527 - 534
  • [5] Effect of mechanical ventilation and natural ventilation on indoor climates in Urumqi residential buildings
    Zhao, Yi
    Sun, Hejiang
    Tu, Daixin
    BUILDING AND ENVIRONMENT, 2018, 144 : 108 - 118
  • [6] Influence of Building Envelope Type on the Minimum Mechanical Ventilation Rate to Achieve a Positive Indoor Air Pressure
    Shi, Yuchen
    Li, Xiaofeng
    Sadatiseyedmahalleh, Seyedehelham
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [7] The influence of music during mechanical ventilation and weaning from mechanical ventilation: A review
    Hetland, Breanna
    Lindquist, Ruth
    Chian, Linda L.
    HEART & LUNG, 2015, 44 (05): : 416 - 425
  • [8] VENTILATION INFLUENCE UPON INDOOR AIR RADON LEVEL
    田德源
    NuclearScienceandTechniques, 1995, (01) : 58 - 60
  • [9] INFLUENCE OF OUTDOOR WIND ENVIRONMENT ON INDOOR NATURAL VENTILATION
    Shi, Yanli
    Zheng, Juan
    Li, Ping
    Zhang, Quan
    Zhang, Guoqiang
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1144 - 1151
  • [10] New approach on zonal modeling of indoor environment with mechanical ventilation
    Song, Fangting
    Zhao, Bin
    Yang, Xudong
    Jiang, Yi
    Gopal, Vipin
    Dobbs, Gregory
    Sahm, Michael
    BUILDING AND ENVIRONMENT, 2008, 43 (03) : 278 - 286