Design and use of internal receiver coils for magnetic resonance imaging

被引:25
|
作者
Gilderdale, DJ [1 ]
deSouza, NM [1 ]
Coutts, GA [1 ]
Chui, MK [1 ]
Larkman, DJ [1 ]
Williams, AD [1 ]
Young, IR [1 ]
机构
[1] Hammersmith Hosp, Imperial Coll Sch Med, Robert Steiner MRI Unit, London W12 0HS, England
来源
BRITISH JOURNAL OF RADIOLOGY | 1999年 / 72卷 / 864期
基金
英国惠康基金;
关键词
D O I
10.1259/bjr.72.864.10703469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This review describes coils for MRI that are inserted into the body through natural orifices. It covers the design and implementation of small internal receiver coils for use in the pelvis and gastrointestinal tract. Normal anatomy delineated by the high resolution obtained by using these coils and the appearances in a number of disease states for each clinical application are described.
引用
收藏
页码:1141 / 1151
页数:11
相关论文
共 50 条
  • [1] Superconducting receiver coils for sodium magnetic resonance imaging
    Miller, JR
    Zhang, K
    Ma, QY
    Mun, IK
    Jung, KJ
    Katz, J
    Face, DW
    Kountz, DJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (12) : 1197 - 1199
  • [2] PHASE AND SENSITIVITY OF RECEIVER COILS IN MAGNETIC-RESONANCE-IMAGING
    MCVEIGH, ER
    BRONSKILL, MJ
    HENKELMAN, RM
    MEDICAL PHYSICS, 1986, 13 (06) : 806 - 814
  • [3] DESIGN OF GRADIENT COILS FOR MAGNETIC-RESONANCE-IMAGING
    ADAMIAK, K
    RUTT, BK
    DABROWSKI, WJ
    IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (05) : 2403 - 2405
  • [4] Design of Axial Shim Coils for Magnetic Resonance Imaging
    Ni, Zhipeng
    Wang, Qiuliang
    Wang, Chunzhong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 2084 - 2087
  • [5] Unshielded Gradient Coils Design For Magnetic Resonance Imaging
    Hidalgo, S. S.
    Gadzinski, C.
    Rutt, B.
    MEDICAL PHYSICS, 2012, 1494 : 54 - 57
  • [6] Gradient Coils Design with Regularization Method for Superconducting Magnetic Resonance Imaging
    Zheng, Sijie
    Li, Xia
    Yan, Wei Qi
    Xu, Wenlong
    2018 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2018,
  • [7] USE OF SURFACE COILS IN MAGNETIC-RESONANCE-IMAGING OF ORBIT AND KNEE
    BEYER, D
    STEINBRICH, W
    FRIEDMANN, G
    ERMERS, JWLM
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (1-2) : 84 - 91
  • [8] High-Tc superconducting rf receiver coils for magnetic resonance imaging of small animals
    Wosik, J
    Nesteruk, K
    Xie, LM
    Strikovski, M
    Wang, F
    Miller, JH
    Bilgen, M
    PHYSICA C, 2000, 341 : 2561 - 2564
  • [9] USE OF SPHERICAL RECEIVER COILS IN MR IMAGING OF THE BRAIN
    BYDDER, GM
    BUTSEN, PC
    HARMAN, RR
    GILDERDALE, DJ
    YOUNG, IR
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (02) : 413 - 414
  • [10] A new fully integrated multichannel receiver design for magnetic resonance imaging
    Jouda, Mazin
    Gruschke, Oliver G.
    Korvink, Jan G.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2016, 46 (03) : 134 - 145