Radiometric calibration pipeline for the EO-1 Advanced Land Imager

被引:0
|
作者
Evans, JB [1 ]
Viggh, HEM [1 ]
机构
[1] MIT, Lincoln Lab, Lexington, MA 02420 USA
来源
EARTH OBSERVING SYSTEMS IV | 1999年 / 3750卷
关键词
radiometric; calibration; implementation; leaky pixel; performance assessment;
D O I
10.1117/12.363508
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This paper covers the design and initial performance analysis of the radiometric calibration pipeline software for the EO-1 Advanced Land Imager (EO-1). The design and implementation of the software and of the radiometric calibration database are discussed. Radiometric calibration data were gathered in the laboratory during integration and test and were used for initializing the database. This database will be updated in the future with data collected on orbit. Initial performance results have been obtained after applying the radiometric calibration to imaging data collected during ALI integration and test and ground calibration. During the initial tests it was noted a few detectors leaked energy into other detectors, thereby requiring special calibration processing for the affected detectors. The handling of this anomaly is discussed, and the initial performance results of the calibration pipeline with the anomaly corrections will be shown.
引用
收藏
页码:153 / 161
页数:9
相关论文
共 50 条
  • [1] Radiometric calibration of the EO-1 Advanced Land Imager
    Mendenhall, JA
    Lencioni, DE
    Parker, AC
    EARTH OBSERVING SYSTEMS IV, 1999, 3750 : 117 - 131
  • [2] EO-1 advanced land imager on-orbit radiometric calibration
    Mendenhall, JA
    Lencioni, DE
    IGARSS 2002: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM AND 24TH CANADIAN SYMPOSIUM ON REMOTE SENSING, VOLS I-VI, PROCEEDINGS: REMOTE SENSING: INTEGRATING OUR VIEW OF THE PLANET, 2002, : 572 - 575
  • [3] Spectral calibration of the EO-1 Advanced Land Imager
    Mendenhall, JA
    Parker, AC
    EARTH OBSERVING SYSTEMS IV, 1999, 3750 : 109 - 116
  • [4] Solar calibration of the EO-1 advanced land imager
    Lencioni, DE
    Mendenhall, JA
    Ryan-Howard, DP
    IGARSS 2001: SCANNING THE PRESENT AND RESOLVING THE FUTURE, VOLS 1-7, PROCEEDINGS, 2001, : 1578 - 1580
  • [5] Spatial calibration of the EO-1 Advanced Land Imager
    Hearn, DR
    Mendenhall, JA
    Willard, BC
    EARTH OBSERVING SYSTEMS IV, 1999, 3750 : 97 - 108
  • [6] Radiometric calibration stability of the EO-1 Advanced Land Imager: 5 years on-orbit
    Markham, Brian L.
    Ong, Lawrence
    Barsi, Julia A.
    Mendenhall, Jeffrey A.
    Lencioni, Donald E.
    Helder, Dennis L.
    Hollaren, Douglas M.
    Morfitt, Ron
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES X, 2006, 6361
  • [7] EO-1 advanced land imager in-flight calibration
    Mendenhall, JA
    Lencioni, DE
    Hearn, DR
    Parker, AC
    EARTH OBSERVING SYSTEMS III, 1998, 3439 : 416 - 422
  • [8] EO-1 advanced land imager calibration and performance overview
    Lencioni, DE
    Hearn, DR
    Mendenhall, JA
    Bicknell, WE
    EARTH OBSERVING SYSTEMS IV, 1999, 3750 : 89 - 96
  • [9] EO-1 advanced land imager
    Bicknell, WE
    Digenis, CJ
    Forman, SE
    Lencioni, DE
    EARTH OBSERVING SYSTEMS IV, 1999, 3750 : 80 - 88
  • [10] EO-1 advanced land imager pre-flight calibration
    Mendenhall, JA
    Lencioni, DE
    Hearn, DR
    Parker, AC
    EARTH OBSERVING SYSTEMS III, 1998, 3439 : 390 - 399