Numerical Investigation of Energy Dissipation Device to Improve Seismic Response of Existing Steel Buildings with Soft-First-Story

被引:9
|
作者
Ahmadi, Masoud [1 ]
Ebadi Jamkhaneh, Mehdi [2 ]
机构
[1] Ayatollah Boroujerdi Univ, Sch Engn, Dept Civil Engn, Boroujerd, Iran
[2] Damghan Univ, Sch Engn, Dept Civil Engn, Damghan, Semnan, Iran
关键词
Soft story; Nonlinear analysis; Energy dissipation; Metallic-yielding damper; Seismic retrofit;
D O I
10.1007/s13296-021-00466-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Retrofitting buildings in densely populated areas with a soft story configuration on the first floor can pose a daunting challenge to the community. Against this backdrop, this study set out to evaluate the seismic retrofit strategy's adequacy in enhancing the seismic performance of buildings with a soft story. The proposed strategy utilizes an earthquake energy dissipation device consisting of a combination of a diagonal brace and a metallic-yielding damper at the ground story level. Two prototype buildings, one with five and the other with ten floors, were chosen to assess the proposed retrofit strategy's seismic response through nonlinear static and dynamic analyses. The seismic capacity, lateral displacement response, maximum inter-story drift ratio, energy dissipation, and collapse fragility are the major response parameters used to compare original and retrofitted buildings. The nonlinear static analysis results revealed that the seismic capacity for buildings equipped with a yielding damper was higher than that of the original buildings. It was also found that retrofitted frame buildings had a desirable structural behavior with a higher value of dissipated energy and a lower value of residual displacements and inter-story drift ratio, in turn reducing the likelihood of soft-story failure.
引用
收藏
页码:691 / 702
页数:12
相关论文
共 15 条
  • [1] Numerical Investigation of Energy Dissipation Device to Improve Seismic Response of Existing Steel Buildings with Soft-First-Story
    Masoud Ahmadi
    Mehdi Ebadi Jamkhaneh
    International Journal of Steel Structures, 2021, 21 : 691 - 702
  • [3] Steel hysteretic column dampers for seismic retrofit of soft-first-story structures
    Javidan, Mohammad Mandi
    Kim, Jinkoo
    STEEL AND COMPOSITE STRUCTURES, 2020, 37 (03): : 259 - 272
  • [4] Seismic Evaluation of a Nonductile Soft-First-Story RC Building Retrofitted with Steel-Braced Frames
    Vahedi, Shahriar
    Javadi, Pasha
    Hosseini, Mir Hamid
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2019, 33 (06)
  • [5] Experimental investigation of shape memory alloy as passive energy dissipation device for seismic response reduction of buildings
    Mao, CX
    Li, H
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 734 - 739
  • [6] Evaluation of seismic torsional response of ductile RC buildings with soft first story
    Hareen, Ch B., V
    Mohan, S. C.
    STRUCTURES, 2021, 29 : 1640 - 1654
  • [7] Application of Energy Dissipation Devices for Seismic Protection of Soft-Story Wood-Frame Buildings in Accordance with FEMA Guidelines
    Tian, Jingjing
    Symans, Michael D.
    Pang, Weichiang
    Ziaei, Ershad
    van de Lindt, John W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (04)
  • [8] High-performance seismic retrofit of soft-story wood-framed buildings using energy dissipation systems
    Tian, Jingjing
    Symans, Michael D.
    Structures Congress 2012 - Proceedings of the 2012 Structures Congress, 2012, : 1790 - 1801
  • [9] Building damages during the September 19, 2017 earthquake in Mexico City and seismic retrofitting of existing first soft-story buildings
    Jara, J. M.
    Hernandez, E. J.
    Olmos, B. A.
    Martinez, G.
    ENGINEERING STRUCTURES, 2020, 209
  • [10] Seismic response control of multi-story asymmetric-plan buildings using pin-supported structures with passive energy dissipation devices
    Miyazu, Yuji
    Ito, Akiyasu
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1725 - 1730