Cryogenic tests of volume-phase holographic gratings - I. Results at 200 K

被引:5
|
作者
Tamura, N [1 ]
Murray, GJ [1 ]
Luke, P [1 ]
Blackburn, C [1 ]
Robertson, DJ [1 ]
Dipper, NA [1 ]
Sharples, RM [1 ]
Allington-Smith, JR [1 ]
机构
[1] Univ Durham, Dept Phys, Durham, England
关键词
gratings; near-infrared; spectrographs;
D O I
10.1023/B:EXPA.0000028163.98901.d9
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH grating are significantly different at a low temperature from those at a room temperature, and to see how many cooling and heating cycles the grating can withstand. We have completed 5 cycles between room temperature and 200 K, and find that the performance is nearly independent of temperature, at least over the temperature range which we are investigating. In future, we will not only try more cycles between these temperatures but also perform measurements at a much lower temperature (e.g., similar to80 K).
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [1] Cryogenic Tests of Volume-Phase Holographic Gratings: I. Results at 200 K
    N. Tamura
    G. J. Murray
    P. Luke
    C. Blackburn
    D. J. Robertson
    N. A. Dipper
    R. M. Sharples
    J. R. Allington-Smith
    Experimental Astronomy, 2003, 15 : 1 - 12
  • [2] Cryogenic tests of volume-phase holographic gratings: results at 100 K
    Tamura, Naoyuki
    Murray, Graham J.
    Luke, Peter
    Blackburn, Colin
    Robertson, David J.
    Dipper, Nigel A.
    Sharples, Ray M.
    Allington-Smith, Jeremy R.
    APPLIED OPTICS, 2006, 45 (23) : 5923 - 5928
  • [3] Cryogenic tests of volume-phase holographic gratings
    Tamura, N
    Murray, GJ
    Luke, P
    Blackburn, C
    Robertson, DJ
    Dipper, NA
    Sharples, RM
    Allington-Smith, JR
    GROUND-BASED INSTRUMENTATION FOR ASTRONOMY, PTS 1-3, 2004, 5492 : 634 - 642
  • [4] Volume-phase holographic gratings and the efficiency of three simple volume-phase holographic gratings
    Barden, SC
    Arns, JA
    Colburn, WS
    Williams, JB
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2000, 112 (772) : 809 - 820
  • [5] Cryogenic Volume-Phase Holographic Grisms for MOIRCS
    Ebizuka, Noboru
    Ichiyama, Kotaro
    Yamada, Toru
    Tokoku, Chihiro
    Onodera, Masato
    Hanesaka, Mai
    Kodate, Kashiko
    Uchimoto, Yuka Katsuno
    Maruyama, Miyoko
    Shimasaku, Kazuhiro
    Tanaka, Ichi
    Yoshikawa, Tomohiro
    Kashikawa, Nobunari
    Iye, Masanori
    Ichikawa, Takashi
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2011, 63 : S605 - S612
  • [6] Astronomical applications of Volume-Phase Holographic gratings
    Barden, SC
    Arns, JA
    Colburn, WS
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 52 - 53
  • [7] Cryogenic volume-phase holographic grisms for MOIRCS
    Ebizuka, Noboru
    Ichiyama, Kotaro
    Yamada, Toru
    Tokoku, Chihiro
    Onodera, Masato
    Hanesaka, Mai
    Kodate, Kashiko
    Uchimoto, Yuka Katsuno
    Maruyama, Miyoko
    Shimasaku, Kazuhiro
    Tanaka, Ichi
    Yoshikawa, Tomohiro
    Kashikawa, Nobunari
    Iye, Masanori
    Ichikawa, Takashi
    Publications of the Astronomical Society of Japan, 2011, 63 (SPEC. ISSUE 2)
  • [8] Spectral multiplexing using stacked volume-phase holographic gratings - I
    Zanutta, A.
    Landoni, M.
    Riva, M.
    Bianco, A.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2017, 469 (02) : 2412 - 2422
  • [9] Volume-phase holographic gratings and their potential for astronomical applications
    Barden, SC
    Arns, JA
    Colburn, WS
    OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 : 866 - 876
  • [10] Volume-phase holographic gratings benefit DWDM systems
    Arns, J
    Tedesco, J
    LASER FOCUS WORLD, 2000, : 59 - +