Error analysis of speed of sound reconstruction in ultrasound limited angle transmission tomography

被引:0
|
作者
Jintamethasawat, Rungroj [1 ,2 ]
Lee, Won-Mean [1 ,3 ]
Carson, Paul L. [1 ,2 ]
Hooi, Fong Ming [1 ,4 ]
Fowlkes, J. Brian [1 ,2 ]
Goodsitt, Mitchell M. [1 ,5 ]
Sampson, Richard [6 ]
Wenisch, Thomas F. [6 ]
Wei, Siyuan [7 ]
Zhou, Jian [7 ]
Chakrabarti, Chaitali [7 ]
Kripfgans, Oliver D. [1 ,2 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] GE Healthcare, 447 Indio Way, Sunnyvale, CA 94085 USA
[4] Siemens Med Solut USA Inc, 22010 South East 51st St, Issaquah, WA 98029 USA
[5] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[6] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[7] Arizona State Univ, Sch Elect Comp & Energy Engn, Tempe, AZ 85287 USA
关键词
Medical imaging; Medical transducers; Breast ultrasound; ACOUSTIC INVERSE SCATTERING; IMAGE SEGMENTATION; BREAST-CANCER; MODEL;
D O I
10.1016/j.ultras.2018.03.016
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We have investigated limited angle transmission tomography to estimate speed of sound (SOS) distributions for breast cancer detection. That requires both accurate delineations of major tissues, in this case by segmentation of prior B-mode images, and calibration of the relative positions of the opposed transducers. Experimental sensitivity evaluation of the reconstructions with respect to segmentation and calibration errors is difficult with our current system. Therefore, parametric studies of SOS errors in our bent-ray reconstructions were simulated. They included mis-segmentation of an object of interest or a nearby object, and miscalibration of relative transducer positions in 3D. Close correspondence of reconstruction accuracy was verified in the simplest case, a cylindrical object in homogeneous background with induced segmentation and calibration inaccuracies. Simulated mis-segmentation in object size and lateral location produced maximum SOS errors of 6.3% within 10 mm diameter change and 9.1% within 5 mm shift, respectively. Modest errors in assumed transducer separation produced the maximum SOS error from miscalibrations (57.3% within 5 mm shift), still, correction of this type of error can easily be achieved in the clinic. This study should aid in designing adequate transducer mounts and calibration procedures, and in specification of B-mode image quality and segmentation algorithms for limited angle transmission tomography relying on ray tracing algorithms.
引用
收藏
页码:174 / 184
页数:11
相关论文
共 50 条
  • [1] Speed of sound ultrasound transmission tomography image reconstruction based on Bezier curves
    Perez-Liva, Mailyn
    Manuel Udias, Jose
    Camacho, Jorge
    Mercep, Elena
    Luis Dean-Ben, Xose
    Razansky, Daniel
    Herraiz, Joaquin L.
    ULTRASONICS, 2020, 103 (103)
  • [2] CNN plus Back-projection: Limited Angle Ultrasound Tomography for Speed of Sound Estimation
    Abu Anas, Emran Mohammad
    Cheng, Alexis
    Seifabadi, Reza
    Wu, Yixuan
    Aalamifar, Fereshteh
    Wood, Bradford
    Rahmim, Arman
    Boctor, Emad M.
    MEDICAL IMAGING 2019: ULTRASONIC IMAGING AND TOMOGRAPHY, 2019, 10955
  • [3] Accelerating ultrasound speed of sound tomography through reflection and transmission imaging
    You, Qi
    Zheng, Yingqiao
    Zhu, Yunhao
    Wang, Yuxin
    Yuan, Jie
    Jintamethasawat, Rungroj
    Wang, Xueding
    Carson, Paul L.
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [4] Sound-Speed Image Reconstruction in Sparse-Aperture 3-D Ultrasound Transmission Tomography
    Jirik, Radovan
    Peterlik, Igor
    Ruiter, Nicole
    Fousek, Jan
    Dapp, Robin
    Zapf, Michael
    Jan, Jiri
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (02) : 254 - 264
  • [5] A New Sound Speed Reconstruction Algorithm for Breast Tissue in Ultrasound Computed Tomography
    Zhao, Yue
    Li, Zhiyuan
    Zhang, Nuomin
    Huang, Hao
    Yuan, Yu
    Jin, Jing
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [6] Dynamic Speed of Sound Adaptive Transmission-Reflection Ultrasound Computed Tomography
    Lin, Xiangwei
    Shi, Hongji
    Fu, Zhenyu
    Lin, Haoming
    Chen, Siping
    Chen, Xin
    Chen, Mian
    SENSORS, 2023, 23 (07)
  • [7] LIMITED ANGLE RECONSTRUCTION IN TOMOGRAPHY VIA SQUASHING
    REEDS, JA
    SHEPP, LA
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (02) : 89 - 97
  • [8] Joint Reconstruction of the Sound Speed and Initial Pressure Distributions for Ultrasound Computed Tomography and Photoacoustic Computed Tomography
    Matthews, Thomas P.
    Anastasio, Mark A.
    MEDICAL IMAGING 2017: ULTRASONIC IMAGING AND TOMOGRAPHY, 2017, 10139
  • [9] Sound speed reconstruction in full wave ultrasound computer tomography for breast cancer detection
    Perez-Liva, M.
    Herraiz, J. L.
    Miller, E.
    Cox, B. T.
    Treeby, B. E.
    Udias, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S454 - S455
  • [10] Waveform Inversion With Source Encoding for Breast Sound Speed Reconstruction in Ultrasound Computed Tomography
    Wang, Kun
    Matthews, Thomas
    Anis, Fatima
    Li, Cuiping
    Duric, Neb
    Anastasio, Mark A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (03) : 475 - 493