Electrocoagulation treatment of raw palm oil mill effluent: Optimization process using high current application

被引:24
|
作者
Nasrullah, Mohd
Ansar, Sabah
Krishnan, Santhana
Singh, Lakhveer
Peera, Shaik Gouse
Zularisam, A. W.
机构
[1] Faculty of Civil Engineering Technology, Universiti Malaysia Pahang (UMP), Lebuhraya Tun Razak, Gambang, Pahang, Kuantan
[2] Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh
[3] PSU Energy Systems Research Institute, Department of Civil Engineering, Faculty of Engineering, Prince of Songkla University, Hat Yai, Songkhla
[4] Energy Cluster, School of Engineering, University of Petroleum and Energy Studies (UPES), Energy Acres, Via Premnager, Dehradun
[5] Department of Civil Engineering, Centre for Research & Development, Chandigarh University, Punjab, Mohali
[6] Department of Environmental Science and Engineering, Keimyung University, Daegu
关键词
Electrocoagulation; High current; Box-behnken design; Chemical oxygen demand; Biological oxygen demand; Suspended solid; WASTE-WATER TREATMENT; BOX-BEHNKEN DESIGN; PROCESS PARAMETERS; ORGANIC-MATTER; REMOVAL; COLOR; POME; PRETREATMENT; PERFORMANCE; COAGULANT;
D O I
10.1016/j.chemosphere.2022.134387
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the electrocoagulation wastewater treatment process, extremely polluted water treatment requires an effective technique, and using high current is one of those. This study aims to optimize electrocoagulation parameters such as operation time, electrodes gap and the initial pH by applying high current intensity to treat palm oil mill effluent (POME) via Box-Behnken design (BBD) method. Chemical oxygen demand (COD), biological oxygen demand (BOD), and suspended solids (SS) were used as the response variables in the quadratic polynomial model. Most of the selected models in the analysis of variance (ANOVA) have shown significant results. A high connection between the parameters and dependent variables was surprisingly discovered in this study which the obtained value of R-2 for removal percentage of COD, BOD and SS were 0.9975, 0.9984 and 0.9979 respectively. Optimal removal was achieved at 19.07 A of current intensity (equivalent to 542 mA/cm(2) of current density), 44.97 min of treatment time, 8.60 mm of inter-electrode distance and 4.37 of pH value, resulted in 97.21%, 99.26% and 99.00% of COD, BOD and SS removal respectively. This optimized scheme of operating parameters combination offers an alternate choice for enhancing the treatment efficiency of POME and also can be a benchmark for other researchers to treat highly polluted wastewater.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application
    Mohd Nasrullah
    A.W.Zularisam
    Santhana Krishnan
    Mimi Sakinah
    Lakhveer Singh
    Yap Wing Fen
    Chinese Journal of Chemical Engineering, 2019, 27 (01) : 208 - 217
  • [2] High performance electrocoagulation process in treating palm oil mill effluent using high current intensity application
    Nasrullah, Mohd
    Zularisam, A. W.
    Krishnan, Santhana
    Sakinah, Mimi
    Singh, Lakhveer
    Fen, Yap Wing
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2019, 27 (01) : 208 - 217
  • [3] Treatment of Palm Oil Mill Effluent by Electrocoagulation Process
    Suwannarat, Tipakorn
    Pisutpaisal, Nipon
    Boonyawanich, Siriorn
    PROGRESS IN ENVIRONMENTAL SCIENCE AND ENGINEERING, PTS 1-4, 2013, 610-613 : 363 - 367
  • [4] Palm Oil Mill Effluent (POME) Treatment by Using An Electrocoagulation Method
    Ahmad, Taib Jamilullail
    Zawawi, Daud
    RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT, 2011, 15 (02): : 606 - 609
  • [5] Electrocoagulation treatment of raw palm oil mill effluent: Effect of operating parameters on floc growth and structure
    Nasrullah, Mohd
    Singh, Lakhveer
    Krishnan, Santhana
    Sakinah, Mimi
    Mahapatra, D. M.
    Zularisam, A. W.
    JOURNAL OF WATER PROCESS ENGINEERING, 2020, 33
  • [6] THE OPTIMIZATION OF THE ELECTROCOAGULATION OF PALM OIL MILL EFFLUENT WITH A BOX-BEHNKEN DESIGN
    Lubis, Mirna Rahmah
    Fujianti, Dwinta Suchy
    Zahara, Rita
    Darmadi
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2019, 10 (01) : 137 - 146
  • [7] Pretreatment of palm oil mill effluent by electrocoagulation and coagulation
    Phalakornkule, Chantaraporn
    Mangmeemak, Juntipa
    Intrachod, Kanita
    Nuntakumjorn, Boonyarit
    SCIENCEASIA, 2010, 36 (02): : 142 - 149
  • [8] Electrocoagulation of Palm Oil Mill Effluent for Treatment and Hydrogen Production Using Response Surface Methodology
    Nasution, Ansori
    Ng, Bee Lan
    Ali, Ehsan
    Yaakob, Zahira
    Kamarudin, Siti Kartom
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2014, 23 (05): : 1669 - 1677
  • [9] Treatment of palm oil mill effluent using electrocoagulation powered by direct photovoltaic solar system
    Mohamad, Zahari
    Razak, Amir Abdul
    Krishnan, Santhana
    Singh, Lakhveer
    Zularisam, A. W.
    Nasrullah, Mohd
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 177 : 578 - 582
  • [10] Electrocoagulation of Palm Oil Mill Effluent as Wastewater Treatment and Hydrogen Production Using Electrode Aluminum
    Nasution, M. Ansori
    Yaakob, Z.
    Ali, Ehsan
    Tasirin, S. M.
    Abdullh, S. R. S.
    JOURNAL OF ENVIRONMENTAL QUALITY, 2011, 40 (04) : 1332 - 1339