Surface-induced dissociation in a Fourier transform ion cyclotron resonance mass spectrometer: Instrument design and evaluation

被引:85
|
作者
Laskin, J [1 ]
Denisov, EV [1 ]
Shukla, AK [1 ]
Barlow, SE [1 ]
Futrell, JH [1 ]
机构
[1] Pacific NW Natl Lab, William R Wiley Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
D O I
10.1021/ac025514q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new Fourier transform ion cyclotron resonance mass spectrometer (FTICR MS) has been constructed in our laboratory. The instrument employs surface-induced dissociation (SID) as an activation method for obtaining structural information on biomolecules in the gas phase. Tandem SID mass spectra can be acquired using either a continuous or a pulsed mode of operation. Collision energy of precursor ion is controlled by a de offset of the ICR cell. Ibis approach eliminates defocusing of the ion beam by the ion-transfer optics as a function of ion kinetic energy and constitutes a significant improvement over our previous experimental setup. Furthermore, it can be easily implemented on any FTICR mass spectrometer. Very high signal-to-noise ratios of 200-500 were obtained in single-scan SID mass spectra of model peptides with acquisition time less than 1.1 s. Reasonable SID signal was detected in single-scan spectra with total acquisition time of only 0.3 s. The high signal-to-noise ratio and the fast acquisition time point on a potential application of SID for high-throughput studies in FTICR MS.
引用
收藏
页码:3255 / 3261
页数:7
相关论文
共 50 条
  • [1] Surface-Induced Dissociation of Protein Complexes in a Hybrid Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    Yan, Jing
    Zhou, Mowei
    Gilbert, Joshua D.
    Wolff, Jeremy J.
    Somogyi, Arpad
    Pedder, Randall E.
    Quintyn, Royston S.
    Morrison, Lindsay J.
    Easterling, Michael L.
    Pasa-Tolic, Ljiljana
    Wysocki, Vicki H.
    ANALYTICAL CHEMISTRY, 2017, 89 (01) : 895 - 901
  • [2] Surface-induced dissociation of the benzene molecular cation in Fourier transform ion cyclotron resonance mass spectrometry
    Rakov, VS
    Denisov, EV
    Laskin, J
    Futrell, JH
    JOURNAL OF PHYSICAL CHEMISTRY A, 2002, 106 (12): : 2781 - 2788
  • [3] Surface-induced dissociation of ions produced by matrix-assisted laser desorption/ionization in a Fourier transform ion cyclotron resonance mass spectrometer
    Laskin, J
    Beck, KM
    Hache, JJ
    Futrell, JH
    ANALYTICAL CHEMISTRY, 2004, 76 (02) : 351 - 356
  • [4] A new approach for effecting surface-induced dissociation in an ion cyclotron resonance mass spectrometer: A modeling study
    Danell, RM
    Glish, GL
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (12) : 1107 - 1117
  • [5] Design and Performance of a Second-Generation Surface-Induced Dissociation Cell for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Native Protein Complexes
    Snyder, Dalton T.
    Panczyk, Erin
    Stiving, Alyssa Q.
    Gilbert, Joshua D.
    Somogyi, Arpad
    Kaplan, Desmond
    Wysocki, Vicki
    ANALYTICAL CHEMISTRY, 2019, 91 (21) : 14049 - 14057
  • [6] Laser microprobe with Fourier transform ion cyclotron resonance mass spectrometer for surface analysis
    Moisio, Harri
    Van Vaeck, Luc
    Vangaever, Frank
    ANALYTICAL CHEMISTRY, 2007, 79 (01) : 280 - 290
  • [7] Design and performance of an atmospheric pressure ion mobility Fourier transform ion cyclotron resonance mass spectrometer
    Tang, Xiaoting
    Bruce, James E.
    Hill, Herbert H., Jr.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (07) : 1115 - 1122
  • [8] SURFACE-INDUCED DISSOCIATION BY FOURIER-TRANSFORM MASS-SPECTROMETRY
    IJAMES, CF
    WILKINS, CL
    ANALYTICAL CHEMISTRY, 1990, 62 (13) : 1295 - 1299
  • [9] Electron capture dissociation of polypeptides using a 3 Tesla Fourier transform ion cyclotron resonance mass spectrometer
    Polfer, NC
    Haselmann, KF
    Zubarev, RA
    Langridge-Smith, PRR
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) : 936 - 943
  • [10] Development of a Fourier-transform ion cyclotron resonance mass spectrometer-ion mobility spectrometer
    Bluhm, BK
    Gillig, KJ
    Russell, DH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11): : 4078 - 4086