Two-Year Course of Corneal Densitometry After Descemet Membrane Endothelial Keratoplasty

被引:31
|
作者
Schaub, Friederike [1 ]
Enders, Philip [1 ]
Bluhm, Cornelius [1 ]
Bachmann, Bjoern O. [1 ]
Cursiefen, Claus [1 ]
Heindl, Ludwig M. [1 ]
机构
[1] Univ Cologne, Dept Ophthalmol, Kerpener Str 62, D-50924 Cologne, Germany
关键词
HIGHER-ORDER ABERRATIONS; KERATOCONUS;
D O I
10.1016/j.ajo.2016.11.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the 2-year course of corneal densitometry following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). DESIGN: Retrospective, interventional case series. METHODS: Densitometry values (corneal light back scatter in grayscale units) measured by Scheimpflugbased imaging and clinical records of 160 eyes of 160 patients undergoing DMEK for FED were reviewed. Outcome measures included densitometry data in 4 corneal layers (anterior layer [AL], central layer [CL], posterior layer [PL], and total layer [TL]) and 2 annuli (central annular zone 0-2 mm and peripheral zone 210 mm), central corneal thickness (CCT), best spectacle-corrected visual acuity (BSCVA), and endothelial cell density (ECD) prior to DMEK and at 1, 3, 6, 12, and 24 months postoperatively. RESULTS: Corneal densitometry decreased in all 4 layers over 2 years after DMEK surgery. Regarding TL 0-2 mm, the reduction of corneal light backscatter was statistically significant for all follow-up time points compared with preoperative values (rho < .001) and compared in between follow-up periods (rho <= .010). Corneal light backscatter reduction was significantly higher in the center (0-2 mm) than in the periphery (2-10 mm) for all layers at 12 and 24 months (rho <= .002). ECD and CCT did not correlate with corneal densitometry, whereas BSCVA correlated moderately for TL 0-2 mm (rho = .026; r = 0.449) and TL 210 mm (P =.001; r = 0.585) at 12 months. CONCLUSIONS: Corneal light backscatter showed a significant reduction after DMEK surgery in Fuchs endothelial dystrophy over a period of 2 years, more pronounced in the corneal center, apparently in association with visual acuity improvement. (Am J Ophthalmol 2017;175:60-67. (C) 2016 Elsevier Inc. All rights reserved.)
引用
收藏
页码:60 / 67
页数:8
相关论文
共 50 条
  • [1] Corneal clarity after Descemet membrane endothelial keratoplasty versus Descemet stripping endothelial keratoplasty: Two-year outcomes
    Lazaridis, A.
    Giallouros, E.
    Sekundo, W.
    Kymionis, G.
    Papaconstantinou, D.
    Chatzistefanou, K.
    Droutsas, K.
    ACTA OPHTHALMOLOGICA, 2017, 95
  • [2] Corneal Densitometry After Secondary Descemet Membrane Endothelial Keratoplasty
    Agha, Bishr
    Dawson, Daniel G.
    Kohnen, Thomas
    Schmack, Ingo
    CORNEA, 2019, 38 (09) : 1083 - 1092
  • [3] Two-Year Refractive Outcomes After Descemet Membrane Endothelial Keratoplasty
    van Dijk, Korine
    Rodriguez-Calvo-de-Mora, Marina
    van Esch, Hilde
    Frank, Laurence
    Dapena, Isabel
    Baydoun, Lamis
    Oellerich, Silke
    Melles, Gerrit R. J.
    CORNEA, 2016, 35 (12) : 1548 - 1555
  • [4] Corneal Densitometry After Uneventful Descemet Membrane Endothelial Keratoplasty-5-Year Outcomes
    Droutsas, Konstantinos
    Kappos, Nikolaos
    Giallouros, Eleftherios
    Schroeder, Frank Michael
    Sekundo, Walter
    Kandarakis, Stylianos
    Lazaridis, Apostolos
    CORNEA, 2022, 41 (08) : 1002 - 1008
  • [5] Impact of corneal donor lens status on two-year course and outcome of Descemet membrane endothelial keratoplasty (DMEK)
    Friederike Schaub
    Layla Pohl
    Philip Enders
    Werner Adler
    Björn O. Bachmann
    Claus Cursiefen
    Ludwig M. Heindl
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2017, 255 : 2407 - 2414
  • [6] Impact of corneal donor lens status on two-year course and outcome of Descemet membrane endothelial keratoplasty (DMEK)
    Schaub, Friederike
    Pohl, Layla
    Enders, Philip
    Adler, Werner
    Bachmann, Bjorn O.
    Cursiefen, Claus
    Heindl, Ludwig M.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 255 (12) : 2407 - 2414
  • [7] Corneal densitometry patterns in Descemet membrane endothelial keratoplasty and Descemet stripping automated keratoplasty
    Jorge Peraza-Nieves
    José-María Sánchez-González
    Carlos Rocha-de-Lossada
    Rahul Rachwani-Anil
    Miriam Sánchez-Valera
    Davide Borroni
    Josep Torras-Sanvicens
    International Ophthalmology, 2023, 43 : 4409 - 4417
  • [8] Corneal densitometry patterns in Descemet membrane endothelial keratoplasty and Descemet stripping automated keratoplasty
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    Rocha-de-Lossada, Carlos
    Rachwani-Anil, Rahul
    Sanchez-Valera, Miriam
    Borroni, Davide
    Torras-Sanvicens, Josep
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4409 - 4417
  • [9] Changes in corneal densitometry after secondary Descemet Membrane Endothelial Keratoplasty (DMEK)
    Schmack, Ingo
    Agha, Bishr
    Dawson, Daniel G.
    Kohnen, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] Two-year clinical outcome after Descemet membrane endothelial keratoplasty using a standardized protocol
    Siddharthan, K. S.
    Shet, Varna
    Agrawal, Anushri
    Reddy, Jagdeesh Kumar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) : 2408 - 2414