The effect of rebamipide ophthalmic suspension on ocular surface mucins in soft contact lens wearers

被引:4
|
作者
Shigeyasu, Chika [1 ,2 ]
Yamada, Masakazu [1 ]
Akune, Yoko [2 ]
Fukui, Masaki [2 ]
机构
[1] Kyorin Univ, Sch Med, Dept Ophthalmol, 6-20-2 Shinkawa, Mitaka, Tokyo 1818611, Japan
[2] Natl Hosp Org Tokyo Med Ctr, Natl Inst Sensory Organs, Div Vis Res, Meguro Ku, 2-5-1 Higashigaoka, Tokyo 1528982, Japan
来源
CONTACT LENS & ANTERIOR EYE | 2018年 / 41卷 / 04期
关键词
Contact lens; Dry eye syndrome; Mucins; Rebamipide; Tears; TFOS INTERNATIONAL WORKSHOP; CLINICAL-EVALUATION; SODIUM HYALURONATE; HUMAN CONJUNCTIVA; DISCOMFORT REPORT; DIQUAFOSOL; INCREASES; BIOSYNTHESIS; SUBSTANCES; OPC-12759;
D O I
10.1016/j.clae.2017.12.016
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes in ocular surface mucins with 2% rebamipide ophthalmic suspension treatment in soft contact lens (SCL) wearers. Rebamipide suspension is a mucin secretagogue approved for the treatment of dry eye syndrome in Japan. In this study, the fluorescence intensity of wheat germ agglutinin conjugate of fluorescein (F-WGA) was used as a marker of membrane-associated mucins, and sialic acid concentration in tear fluids as a marker of secreted mucins. Methods: Thirty-two eyes of 16 SCL wearers with discomfort were treated with rebamipide suspension at a dose of one drop in each eye four times daily for two weeks. The parameters of clinical efficacy were tear break-up time, fluorescein staining scores for the cornea and conjunctiva, and Schirmer test values. Fluorescence intensities in the central cornea were measured by fluorophotometry after the application of 5% F-WGA solution. Tears collected by Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of sialic acid, total protein, and the four major tear proteins, namely secretory IgA, lactoferrin, lipocalin-1, and lysozyme were measured. Results: Significant increases in F-WGA fluorescence intensities (p < 0.005) were seen in the corneal surfaces. Sialic acid concentrations increased over time; however, the differences were not statistically significant. Except for a slight increase in kerato-conjunctival staining scores (p < 0.05) and secretory IgA (p < 0.05), no other significant differences were seen among clinical parameters or tear proteins. Conclusions: Topical application of rebamipide suspension significantly increased F-WGA intensity, a marker of membrane-associated mucins in SCL wearers.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 50 条
  • [1] Fluorophotometric Analysis of the Ocular Surface Glycocalyx in Soft Contact Lens Wearers
    Fukui, Masaki
    Yamada, Masakazu
    Akune, Yoko
    Shigeyasu, Chika
    Tsubota, Kazuo
    CURRENT EYE RESEARCH, 2016, 41 (01) : 9 - 14
  • [2] Effect of wind stimulation on ocular surface temperatures and blood flow in soft contact lens wearers
    Itokawa, Takashi
    Okajima, Yukinobu
    Iwashita, Hiroko
    Kakisu, Koji
    Hori, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [3] Ocular Surface Response in Contact Lens Wearers
    Muselier, A., Jr.
    Souchier, M.
    Mathieu, B.
    Gregoire, S.
    Nicot, F.
    Baudouin, F.
    Bretillon, L.
    Bron, A. M.
    Creuzot-Garcher, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Effects of a 0.9% sodium chloride ophthalmic solution on the ocular surface of symptomatic contact lens wearers
    Barabino, S
    Rolando, M
    Camicione, P
    Chen, W
    Calabria, G
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2005, 40 (01): : 45 - 50
  • [5] Improving ocular surface comfort in contact lens wearers
    Fernandez-Jimenez, Elena
    Diz-Arias, Elena
    Peral, Assumpta
    CONTACT LENS & ANTERIOR EYE, 2022, 45 (03):
  • [6] Ocular response to lens care systems in adolescent soft contact lens wearers
    Soni, PS
    Horner, DG
    Ross, J
    OPTOMETRY AND VISION SCIENCE, 1996, 73 (02) : 70 - 85
  • [7] Tear film and ocular surface changes in frequent replacement soft contact lens wearers.
    Ozmen, AT
    Dogru, M
    Cakal, O
    Ozcetin, H
    Erturk, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S594 - S594
  • [8] Association Between Ocular Surface Temperature and Tear Film Stability in Soft Contact Lens Wearers
    Itokawa, Takashi
    Okajima, Yukinobu
    Suzuki, Takashi
    Kakisu, Koji
    Iwashita, Hiroko
    Murakami, Yoshitaka
    Hori, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 771 - 775
  • [9] Ocular thermography in contact lens wearers
    Rodriguez, Juan Gonzalo Carracedo
    ACTA OPHTHALMOLOGICA, 2019, 97
  • [10] The contact lens dry eyes questionnaire (CLDEQ-8) validation and ocular surface dysfunction among soft contact lens wearers
    Ribeiro, Marcelo
    Vieira, Matheus Schmitz
    Gorgone, Gabriel
    Cominatto Barbosa, Lucas Yunes
    Abdel Fattah Martini, Alexandre Ricardo
    David, Milton Agrizzi
    Fornazari, Denise Oliveira
    Alves, Monica
    Leite Arieta, Carlos Eduardo
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2022, 85 (01) : 68 - 76