Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25 min

被引:27
|
作者
Ahmad, Farhan [1 ]
Stedtfeld, Robert D. [1 ]
Waseem, Hassan [1 ]
Williams, Maggie R. [1 ]
Cupples, Alison M. [1 ]
Tiedje, James M. [2 ,3 ]
Hashsham, Syed A. [1 ,2 ]
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Ctr Microbial Ecol, E Lansing, MI 48824 USA
[3] Michigan State Univ, Dept Microbiol & Mol Genet, E Lansing, MI 48824 USA
关键词
Loop-mediated isothermal amplification; Most probable number; Propidium monoazide; Detection limit; Point-of-care diagnostics; PROPIDIUM MONOAZIDE; DNA AMPLIFICATION; ETHIDIUM MONOAZIDE; MICROFLUIDIC CHIP; PCR; CELLS; ENUMERATION; BACTERIA; BLOOD; POINT;
D O I
10.1016/j.mimet.2016.11.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95 degrees C for 5 min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63 degrees C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting <10 CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of <10 CFU, and time to positivity of about 20 min. MPN-LAMP assays were performed for cell concentrations in the range of 105 CFU to <10 CFU. MPN values from LAMP assays confirmed that the amplifications were from <10 CFU. The method described here, applicable directly on cells at 63 degrees C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 25 条
  • [1] Rapid and sensitive enumeration of total coliforms and Escherichia coli in water and foods by most-probable-number loop-mediated isothermal amplification (MPN-LAMP) method
    Tongphrom, Chonnikan
    Preeprem, Sutima
    Nishibushi, Mitsuaki
    Vuddhakul, Varaporn
    Mittraparp-arthorn, Pimonsri
    SCIENCEASIA, 2018, 44 (05): : 365 - 370
  • [2] Rapid quantification of fecal indicator bacteria in water using the most probable number-loop-mediated isothermal amplification (MPN-LAMP) approach on a polymethyl methacrylate (PMMA) microchip
    Fu, Jing
    Chiang, Elaine Li Ching
    Medriano, Carl Angelo Dulatre
    Li, Liyan
    Bae, Sungwoo
    WATER RESEARCH, 2021, 199
  • [3] Current loop-mediated isothermal amplification (LAMP) technologies for the detection of poultry pathogens
    Ehtisham-Ul-Haque, S.
    Zaman, M. A.
    Kiran, M.
    Rafique, M. K.
    Qamar, M. F.
    Younus, M.
    WORLDS POULTRY SCIENCE JOURNAL, 2018, 74 (02) : 287 - 300
  • [4] Loop-mediated isothermal amplification (LAMP): A novel rapid detection platform for pathogens
    Li, Yanmei
    Fan, Penghui
    Zhou, Shishui
    Zhang, Li
    MICROBIAL PATHOGENESIS, 2017, 107 : 54 - 61
  • [5] Recent advances in loop-mediated isothermal amplification (LAMP) for rapid and efficient detection of pathogens
    Garg, Nupur
    Ahmad, Farhan Jalees
    Kar, Sudeshna
    CURRENT RESEARCH IN MICROBIAL SCIENCES, 2022, 3
  • [6] Rapid In-Field Detection of Airborne Pathogens Using Loop-Mediated Isothermal Amplification (LAMP)
    Bani, Alessia
    Whitby, Corinne
    Colbeck, Ian
    Dumbrell, Alex J.
    Ferguson, Robert M. W.
    MICROORGANISMS, 2024, 12 (12)
  • [7] The application of loop-mediated isothermal amplification (LAMP) in food testing for bacterial pathogens and fungal contaminants
    Niessen, Ludwig
    Luo, Jie
    Denschlag, Carla
    Vogel, Rudi F.
    FOOD MICROBIOLOGY, 2013, 36 (02) : 191 - 206
  • [8] Loop-mediated isothermal amplification (LAMP) assays for detection and identification of aquaculture pathogens: current state and perspectives
    Biswas, Gouranga
    Sakai, Masahiro
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2014, 98 (07) : 2881 - 2895
  • [9] An Empirical Approach for Quantifying Loop-Mediated Isothermal Amplification (LAMP) Using Escherichia coli as a Model System
    Subramanian, Sowmya
    Gomez, Romel D.
    PLOS ONE, 2014, 9 (06):
  • [10] Loop-mediated isothermal amplification (LAMP) assays for detection and identification of aquaculture pathogens: current state and perspectives
    Gouranga Biswas
    Masahiro Sakai
    Applied Microbiology and Biotechnology, 2014, 98 : 2881 - 2895