A Low Noise and High Dynamic Range CMOS Integrated Electronics associated with Double Sided Silicon Strip Detectors for a Compton Camera gamma-ray Detecting System

被引:0
|
作者
Dahoumane, Mokrane [1 ,2 ,3 ]
Dauvergne, D. [1 ,2 ,3 ]
Krimmer, J. [1 ,2 ,3 ]
Ley, J. -L. [1 ,2 ,3 ]
Testa, E. [1 ,2 ,3 ]
Zoccarato, Y. [1 ,2 ,3 ]
机构
[1] Univ Lyon, IPNL, F-69003 Lyon, France
[2] Univ Lyon 1, F-69622 Villeurbanne, France
[3] CNRS, IN2P3, UMR 5822, F-69622 Villeurbanne, France
关键词
DESIGN;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An 8-channel Front End integrated Electronics (FEE) circuit is designed and fabricated using the AMS-CMOS 0.35 mu m process to equip a Compton camera system for quality control in Hadrontherapy. The circuit provides the energy deposited by prompt gamma rays interacting in a 2 mm thick Double sided Silicon Strip Detector (DSSD), the (x,y,z) space coordinates and the time of the interaction. Each channel includes a Charge Sensitive Amplifier (CSA) followed by two parallel shapers. Slow and fast shapers, with 1 mu s and 15 ns shaping time are used to measure the energy and time stamping, respectively. In order to increase the detection efficiency, a 3 bit multi-gain configuration is chosen to implement the fast shaper. The output of the latter is sent to a voltage comparator which provides a digital signal used as event time stamp and resetting signal of the CSA feedback capacitor to avoid pileup or circuit saturation. A 5 bit DAC is integrated to compensate any comparator offset dispersion between channels. A programmable digital circuit is also integrated in this design to adjust the delay and the width of the reset signal. All configuration settings are controlled by an I2C interface circuit which is integrated in the circuit. The present design provides the readout of the two sides of the DSSD thanks to a hole or electron configurable system. All the functionalities of the design have been successfully tested and validated. The test results are in good agreement with analytical and simulation calculations. A high linearity over a range of 3x10(3) to 3x10(6) electrons is reached with a conversion gain of 3.6 mV/fC. The circuit (CSA output) achieves an ENC (Equivalent Noise Charge) of 290 electrons rms. The circuit dissipates 23 mW/channel and occupies an area of 2x4.5 mm(2), including pads.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] Low-noise double-sided silicon strip detector for soft gamma-ray compton camera
    Fukazawa, Y
    Nakamoto, T
    Sawamoto, N
    Uno, S
    Ohsugi, T
    Tajima, H
    Takahashi, T
    Mitani, T
    Tanaka, T
    Nakazawa, K
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 197 - 207
  • [2] Development of low-noise double-sided silicon strip detector for cosmic soft gamma-ray Compton Camera
    Fukazawa, Y
    Nakamoto, T
    Sawamoto, N
    Uno, S
    Ohsugi, T
    Tajima, H
    Takahashi, T
    Mitani, T
    Tanaka, T
    Nakazawa, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 342 - 349
  • [3] Low noise double-sided silicon strip detector for multiple-compton gamma-ray telescope
    Tajima, H
    Kamae, T
    Uno, S
    Nakamoto, T
    Fukazawa, Y
    Mitanic, T
    Takahashi, T
    Nakazawa, K
    Okada, Y
    Nomachi, M
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 875 - 884
  • [4] READOUT OF DOUBLE-SIDED SILICON STRIP DETECTORS WITH HIGH-DENSITY INTEGRATED ELECTRONICS
    BECKER, H
    CATTANEO, P
    DIETL, H
    HAUFF, D
    LANGE, E
    LUTZ, G
    MOSER, HG
    SCHWARZ, AS
    SETTLES, R
    HOLL, P
    BUTTLER, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 246 - 250
  • [5] A Low Noise and High Dynamic Charge Sensitive Amplifier-Shaper associated with Silicon Strip Detector for Compton Camera in hadrontherapy
    Dahoumane, M.
    Dauvergne, D.
    Krimmer, J.
    Mathez, H.
    Ray, C.
    Testa, E.
    Walenta, A. H.
    Zoccarato, Y.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1445 - 1451
  • [6] Exploring Various Isolation Techniques to Develop Low Noise, Radiation Hard Double-Sided Silicon Strip Detectors for the CBM Silicon Tracking System
    Chatterji, Sudeep
    Singla, Minni
    Mueller, Walter F. J.
    Heuser, Johann M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 2254 - 2265
  • [7] Development of the multi-purpose gamma-ray detection system consisting of a double-sided silicon strip detector and a 25-segmented germanium detector
    Lee, JH
    Kim, NY
    Lee, CS
    Jang, ZH
    NUCLEAR PHYSICS A, 2005, 758 : 150C - 153C
  • [8] 2-mm-thick large-area CdTe double-sided strip detectors for high-resolution spectroscopic imaging of X-ray and gamma-ray with depth-of-interaction sensing
    Minami, Takahiro
    Katsuragawa, Miho
    Nagasawa, Shunsaku
    Takeda, Shin'ichiro
    Watanabe, Shin
    Tsuzuki, Yutaka
    Takahashi, Tadayuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1059