Stability and detection performance of a GEM-based Optical Readout TPC with He/CF4 gas mixtures

被引:10
|
作者
Baracchini, E. [1 ,2 ]
Benussi, L. [3 ]
Bianco, S. [3 ]
Capoccia, C. [3 ]
Caponero, M. [3 ,4 ]
Cavoto, G. [5 ,6 ]
Cortez, A. [1 ,2 ]
Costa, I. A. [7 ]
Di Marco, E. [5 ]
D'Imperio, G. [5 ]
Dho, G. [1 ,2 ]
Iacoangeli, F. [5 ]
Maccarrone, G. [3 ]
Marafini, M. [5 ,8 ,9 ]
Mazzitelli, G. [3 ]
Messina, A. [5 ,6 ]
Nobrega, R. A. [7 ]
Orlandi, A. [3 ]
Paoletti, E. [3 ]
Passamonti, L. [3 ]
Petrucci, F. [10 ,11 ]
Piccolo, D. [3 ]
Pierluigi, D. [3 ]
Pinci, D. [5 ]
Renga, F. [5 ]
Rosatelli, F. [3 ]
Russo, A. [3 ]
Saviano, G. [3 ,12 ]
Tomassini, S. [3 ]
机构
[1] Gran Sasso Sci Inst, Laquila, Italy
[2] Ist Nazl Fis Nucl, Lab Nazl Gran Sasso, Assergi, Italy
[3] Ist Nazl Fis Nucl, Lab Nazl Frascati, Frascati, Italy
[4] ENEA Ctr Ric Frascati, Frascati, Italy
[5] Ist Nazl Fis Nucl, Sez Roma, Rome, Italy
[6] Sapienza Univ Roma, Dipartimento Fis, Rome, Italy
[7] Univ Fed Juiz de Fora, Juiz De Fora, Brazil
[8] Museo Stor Fis, Piazza Viminale 1, Rome, Italy
[9] Ctr Studi & Ric Enrico Fermi, Piazza Viminale 1, Rome, Italy
[10] Univ Roma TRE, Dipartimento Matemat & Fis, Rome, Italy
[11] Ist Nazl Fis Nucl, Sez Roma TRE, Rome, Italy
[12] Sapienza Univ Roma, Dipartimento Ingn Chim Mat & Ambiente, Rome, Italy
来源
JOURNAL OF INSTRUMENTATION | 2020年 / 15卷 / 10期
基金
欧洲研究理事会;
关键词
Dark Matter detectors (WIMPs; axions etc.); Gaseous imaging and tracking detectors; Micropattern gaseous detectors (MSGC; GEM; THGEM; RETHGEM; MHSP; MICROPIC; MICROMEGAS; InGrid etc); Time projection Chambers (TPC); SCINTILLATION;
D O I
10.1088/1748-0221/15/10/P10001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance and long term stability of an optically readout Time Projection Chamber with an electron amplification structure based on three Gas Electron Multipliers was studied. He/CF4 based gas mixtures were used in two different proportions (60/40 and 70/30) in a CYGNO prototype with 7 litres sensitive volume. With electrical configurations providing very similar electron gains, an almost full detection efficiency in the whole detector volume was found with both mixtures, while a light yield about 20% larger for the 60/40 was found. The electrostatic stability was tested by monitoring voltages and currents during 25 days. The detector worked in very stable and safe condition for the whole period. In the presence of less CF4, a larger probability of unstable events was clearly detected.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] Performance of an optical readout GEM-based TPC
    Margato, LMS
    Fraga, FAF
    Fetal, STG
    Fraga, MMFR
    Balau, EFS
    Blanco, A
    Marques, RF
    Policarpo, AJPL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 231 - 235
  • [2] Combined Optical and Electronic Readout for Event Reconstruction in a GEM-Based TPC
    Brunbauer, Florian M.
    Garcia, Francisco
    Korkalainen, Tero
    Lugstein, Alois
    Lupberger, Michael
    Oliveri, Eraldo
    Pfeiffer, Dorothea
    Ropelewski, Leszek
    Thuiner, Patrik
    Schinnerl, Markus
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (03) : 913 - 918
  • [3] Development of a prototype TPC with CF4 & GEM readout for heavy ion collision
    Isobe, T
    Hamagaki, H
    Ozawa, K
    Inuzuka, M
    Sakaguchi, T
    Kajihara, F
    Gunji, T
    Kurihara, N
    Sawada, S
    Yokkaichi, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3652 - 3656
  • [4] Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures
    Kobayashi, M.
    Yonamine, R.
    Tomioka, T.
    Aoza, A.
    Bito, H.
    Fujii, K.
    Higashi, T.
    Hiramatsu, K.
    Ikematsu, K.
    Ishikawa, A.
    Kato, Y.
    Kuroiwa, H.
    Matsuda, T.
    Nitoh, O.
    Ohta, H.
    Sakai, K.
    Settles, R. D.
    Sugiyama, A.
    Tsuji, H.
    Watanabe, T.
    Yamaoka, H.
    Yazu, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 641 (01): : 37 - 47
  • [5] Performance of optically readout GEM-based TPC with a 55Fe source
    Costa, I. Abritta
    Baracchini, E.
    Bellini, F.
    Benussi, L.
    Bianco, S.
    Caponero, M. A.
    Cavoto, G.
    D'Imperio, G.
    Di Marco, E.
    Maccarrone, G.
    Marafini, M.
    Mazzitelli, E. G.
    Messina, A.
    Petrucci, F.
    Piccolo, D.
    Pinci, D.
    Renga, L. F.
    Rosatelli, A. F.
    Saviano, G.
    Tomassini, S.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (07)
  • [6] Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures: II
    Kobayashi, M.
    Yonamine, R.
    Tomioka, T.
    Aoza, A.
    Bito, H.
    Fujii, K.
    Higashi, T.
    Hiramatsu, K.
    Ikematsu, K.
    Ishikawa, A.
    Kato, Y.
    Kuroiwa, H.
    Matsuda, T.
    Nitoh, O.
    Ohta, H.
    Sakai, K.
    Settles, R. D.
    Sugiyama, A.
    Tsuji, H.
    Watanabe, T.
    Yamaoka, H.
    Yazu, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 767 : 439 - 444
  • [7] GEM-MIGAS Gain Optimisation for High Pressure Operation in CF4 and He/CF4 Mixtures
    Conceicao, Ana Sofia
    Mir, Jamil A.
    dos Santos, Joaquim M. F.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2407 - 2412
  • [8] Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures (vol 641, pg 37, 2011)
    Kobayashi, M.
    Yonamine, R.
    Tomioka, T.
    Aoza, A.
    Bito, H.
    Fujii, K.
    Higashi, T.
    Hiramatsu, K.
    Ikematsu, K.
    Ishikawa, A.
    Kato, Y.
    Kuroiwa, H.
    Matsuda, T.
    Nitoh, O.
    Ohta, H.
    Sakai, K.
    Settles, R. D.
    Sugiyama, A.
    Tsuji, H.
    Watanabe, T.
    Yamaoka, H.
    Yazu, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 988
  • [9] Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures (vol 641, pg 37, 2011)
    Kobayashi, M.
    Yonamine, R.
    Tomioka, T.
    Aoza, A.
    Bito, H.
    Fujii, K.
    Higashi, T.
    Hiramatsu, K.
    Ikematsu, K.
    Ishikawa, A.
    Kato, Y.
    Kuroiwa, H.
    Matsuda, T.
    Nitoh, O.
    Ohta, H.
    Sakai, K.
    Settles, R. D.
    Sugiyama, A.
    Tsuji, H.
    Watanabe, T.
    Yamaoka, H.
    Yazu, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 764 : 394 - 394
  • [10] Cosmic ray tests of a GEM-based TPC prototype operated in Ar-CF4-isobutane gas mixtures (vol 641, pg 37, 2011)
    Kobayashi, M.
    Yonamine, R.
    Tomioka, T.
    Aoza, A.
    Bito, H.
    Fujii, K.
    Higashi, T.
    Hiramatsu, K.
    Ikematsu, K.
    Ishikawa, A.
    Kato, Y.
    Kuroiwa, H.
    Matsuda, T.
    Nitoh, O.
    Ohta, H.
    Sakai, K.
    Settles, R. D.
    Sugiyama, A.
    Tsuji, H.
    Watanabe, T.
    Yamaoka, H.
    Yazu, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1051