Understanding the Origin of Oscillatory Phenomena Observed Between Wind Farms and HVdc Systems

被引:166
作者
Amin, Mohammad [1 ]
Molinas, Marta [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Engn Cybernet, N-7491 Trondheim, Norway
关键词
Active damping; control of voltage-source converter (VSC); harmonic resonance; high voltage dc (HVdc); offshore grid; stability analysis; subsynchronous oscillation (SSO); wind farm (WF); SUBSYNCHRONOUS RESONANCE; TRANSMISSION; INTEGRATION; MITIGATION; STABILITY; MODEL; SSR;
D O I
10.1109/JESTPE.2016.2620378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Field experience has shown that subsynchronous oscillation and harmonic resonance can occur between wind farms (WFs) and high voltage dc (HVdc) systems. The oscillations can appear in the presence of background harmonics due to the interaction between the wind energy conversion system's (WECS's) converter controller, HVdc converter controller, and the impact of the interconnection system impedance. However, the root causes of these oscillations observed in the field are not entirely understood and they can be attributed to various sources within the components and controllers of the interconnected system. This paper explores the possible causes of these oscillations by investigating the impact of controllers and components in the WF and in the voltage-source converter (VSC)-based HVdc transmission system. In order to understand this phenomenon, the impedance of both the WF and the HVdc from the offshore ac collection point is analytically derived to identify potential resonance points. The impedance frequency responses of the WF and the HVdc converter indicate the potential resonance at low frequency. The origin of these oscillations can be attributed to the propagation of the WECS resonance through the WECS full converter dc link and the interaction between the WECS and the HVdc system. Once the source and the load impedance are identified, an impedance-based stability method is adopted in order to determine the stability. In an attempt to improve the oscillatory phenomena, an active damping scheme is implemented on the offshore HVdc rectifier. An analysis and time-domain simulation results with its respective harmonic spectra show that the implemented active damping is very effective in eliminating the oscillations observed in the interconnected system. Moreover, this paper presents the role of the ratio between the bandwidths of the interconnected areas, as having an essential role in the root cause of the instability. The general rule is observed that when the bandwidth of the HVdc rectifier (which is the source) is faster than the bandwidth of the load (WFs inverter); the system operates stably.
引用
收藏
页码:378 / 392
页数:15
相关论文
共 40 条
[1]   Half- and Full-Bridge Modular Multilevel Converter Models for Simulations of Full-Scale HVDC Links and Multiterminal DC Grids [J].
Adam, Grain P. ;
Williams, Barry W. .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (04) :1089-1108
[2]  
Amin M, 2015, IEEE W CONTR MODEL
[3]  
[Anonymous], IEEE T POWE IN PRESS
[4]  
[Anonymous], P 8 ANN IEEE EN CONV
[5]  
[Anonymous], P POW EN SOC GEN M
[6]  
[Anonymous], COMPUTER AIDED CONTR
[7]  
Bajracharya C., 2008, P NORD WORKSH POW IN, P1
[8]   A new mathematical model and control of a three-phase AC-DC voltage source converter [J].
Blasko, V ;
Kaura, V .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :116-123
[9]  
Bradt M., 2011, 2011 IEEE Power and Energy Society General Meeting, P1
[10]   On the Ac Stability of High Power Factor Three-Phase Rectifiers [J].
Burgos, Rolando ;
Boroyevich, Dushan ;
Wang, Fred ;
Karimi, Kamiar ;
Francis, Gerald .
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, :2047-2054