共 50 条
Dispersive micro-solid-phase extraction of benzodiazepines from biological fluids based on polyaniline/magnetic nanoparticles composite
被引:135
|作者:
Asgharinezhad, Ali Akbar
[1
]
Ebrahimzadeh, Homeira
[1
]
Mirbabaei, Fatemeh
[1
]
Mollazadeh, Narges
[1
]
Shekari, Nafiseh
[1
]
机构:
[1] Shahid Beheshti Univ, Fac Chem, GC, Tehran, Iran
关键词:
Fe3O4-polyaniline nanocomposite;
Dispersive-mu-solid phase extraction;
Lorazepam;
Nitrazepam;
Preconcentration;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
POLYCYCLIC AROMATIC-HYDROCARBONS;
COATED MAGNETIC NANOPARTICLES;
PHENOLIC-COMPOUNDS;
MICROEXTRACTION;
WATER;
URINE;
SORBENT;
PLASMA;
DRUGS;
D O I:
10.1016/j.aca.2014.06.007
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
In this study, diverse types of Fe3O4 nanocomposites modified by polyaniline, polypyrrole, and aniline-pyrrole copolymer were synthesized through chemical oxidative polymerization process for dispersive-mu-solid phase extraction (D-mu-SPE) in the presence of various dopants. The results showed that the nanocomposite modified by polyaniline with p-toluene sulfonic acid as a dopant demonstrated higher extraction efficiency for lorazepam (LRZ) and nitrazepam (NRZ). Also the synthesized magnetic sorbents were characterized. The nanocomposite sorbent in combination with high performance liquid chromatography-UV detection was applied for the extraction, preconcentration and determination of lorazepam and nitrazepam in urine and plasma samples. Different parameters influencing the extraction efficiency including: sample pH, amount of sorbent, sorption time, elution solvent and its volume, salt content, and elution time were optimized. The obtained optimal conditions were: sample pH, 6; amount of sorbent, 5 mg; sorption time, 5.0 min; elution solvent and its volume, 0.5 mM cethyltrimethyl ammonium bromide in acetonitrile, 150 mu L; elution time, 2.0 min and without addition of NaCl. The calibration curves were linear in the concentration range of 1-2000 mu g L (-1). The limits of detection (LODs) were achieved in the range of 0.5-1.8 mu g L (-1) for NRZ and 0.2-2.0 mu g L (-1) for LRZ, respectively. The percent of extraction recoveries and relative standard deviations (n = 5) were in the range of 84.0-99.0, 6.1-7.8 for NRZ and 90.0-99.0, 4.1-7.0 for LRZ, respectively. Ultimately, the applicability of the method was successfully confirmed by the extraction and determination of NRZ and LRZ in human urine and plasma samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:80 / 89
页数:10
相关论文