On Medical Device Software CE Compliance and Conformity Assessment

被引:0
|
作者
Granlund, Tuomas [1 ]
Mikkonen, Tommi [2 ]
Stirbu, Vlad [3 ]
机构
[1] Solita Oy, Tampere, Finland
[2] Univ Helsinki, Helsinki, Finland
[3] CompliancePal, Tampere, Finland
关键词
Medical device software; medical software development; medical device standards; regulatory requirements; regulatory compliance;
D O I
10.1109/ICSA-050368.2020.00040
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Manufacturing of medical devices is strictly controlled by authorities, and manufacturers must conform to the regulatory requirements of the region in which a medical device is being marketed for use. In general, these requirements make no difference between the physical device, embedded software running inside a physical device, or software that constitutes the device in itself. As a result, standalone software with intended medical use is considered to be a medical device. Consequently, its development must meet the same requirements as the physical medical device manufacturing. This practice creates a unique challenge for organizations developing medical software. In this paper, we pinpoint a number of regulatory requirement mismatches between physical medical devices and standalone medical device software. The view is based on experiences from industry, from the development of all -software medical devices as well as from defining the manufacturing process so that it meets the regulatory requirements.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 50 条
  • [1] Developing Medical Device Software in compliance with regulations
    Zema, M.
    Rosati, S.
    Gioia, V.
    Knaflitz, M.
    Balestra, G.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 1331 - 1334
  • [2] The Impact of Regulatory Compliance on Agile Software Processes with a Focus on the FDA Guidelines for Medical Device Software
    Mehrfard, Hossein
    Hamou-Lhadj, Abdelwahab
    INTERNATIONAL JOURNAL OF INFORMATION SYSTEM MODELING AND DESIGN, 2011, 2 (02) : 67 - 81
  • [4] A lightweight traceability assessment method for medical device software
    Casey, Valentine
    Mc Caffery, Fergal
    JOURNAL OF SOFTWARE-EVOLUTION AND PROCESS, 2013, 25 (04) : 363 - 372
  • [5] Risk Assessment and Classification of Medical Device Software for the Internet of Medical Things
    Brass, Irina
    Mkwashi, Andrew
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON THE INTERNET OF THINGS 2022, IOT 2022, 2022, : 171 - 178
  • [6] Summary of Conformity Assessment for Apparatus (CE Marking)
    Marshman, Chris
    2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1-3, 2008, : 1465 - 1466
  • [7] Development of MDevSPICE® - the medical device software process assessment framework
    Lepmets, Marion
    Clarke, Paul
    McCaffery, Fergal
    Finnegan, Anita
    Dorling, Alec
    JOURNAL OF SOFTWARE-EVOLUTION AND PROCESS, 2015, 27 (08) : 565 - 572
  • [8] A hybrid assessment approach for medical device software development companies
    Ozcan-Top, Ozden
    McCaffery, Fergal
    JOURNAL OF SOFTWARE-EVOLUTION AND PROCESS, 2018, 30 (07)
  • [9] Requirements for a method of software accessibility conformity assessment
    Alonso, Fernando
    Fuertes, Jose L.
    Gonzalez, Angel L.
    Martinez, Loic
    COMPUTERS HELPING PEOPLE WITH SPECIAL NEEDS, PROCEEDINGS, 2008, 5105 : 534 - 541
  • [10] Is read-across for chemicals comparable to medical device equivalence and where to use it for conformity assessment?
    Suendermann, Jan
    Bitsch, Annette
    Kellner, Rupert
    Doll, Theodor
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2024, 149