Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters

被引:56
|
作者
Farnsworth, James E.
Goyal, Sagar M.
Kim, Seung Won
Kuehn, Thomas H.
Raynor, Peter C.
Ramakrishnan, M. A.
Anantharaman, Senthilvelan
Tang, Weihua
机构
[1] TSI Inc, Dept Engn, St Paul, MN 55126 USA
[2] Univ Minnesota, Dept Mech Engn, Environm Div, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Dept Vet Populat Med, St Paul, MN 55108 USA
[4] Univ Minnesota, Sch Publ Hlth, Div Environm Hlth Sci, Minneapolis, MN 55455 USA
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2006年 / 8卷 / 10期
关键词
D O I
10.1039/b606132j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of the work presented here is to study the effectiveness of building air handling units ( AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus ( TGEV), avian pneumovirus ( APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies ( 0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.
引用
收藏
页码:1006 / 1013
页数:8
相关论文
共 50 条
  • [1] Fungi and bacteria on air filters from heating, ventilation, and air-conditioning systems: A method for the determination of fungi and bacteria on air filters
    Moritz, M
    Martiny, H
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1997, 199 (06): : 513 - 526
  • [2] Heating, ventilation, and air-conditioning (HVAC) systems in the OR
    Johnstone, Esther M.
    AORN JOURNAL, 2017, 106 (05) : 444 - 445
  • [3] Heating, ventilation and air conditioning (HVAC) in intensive care unit
    Sai Saran
    Mohan Gurjar
    Arvind Baronia
    Vijayalakshmi Sivapurapu
    Pralay S. Ghosh
    Gautham M. Raju
    Indubala Maurya
    Critical Care, 24
  • [4] Heating, ventilation and air conditioning (HVAC) in intensive care unit
    Saran, Sai
    Gurjar, Mohan
    Baronia, Arvind
    Sivapurapu, Vijayalakshmi
    Ghosh, Pralay S.
    Raju, Gautham M.
    Maurya, Indubala
    CRITICAL CARE, 2020, 24 (01)
  • [5] Exergy Analysis of a Heating Ventilation and Air Conditioning (HVAC) System
    Prakash, K.
    Islam, F. R.
    Mamun, K. A.
    Sharma, A.
    Sen, A.
    2018 IEEE 7TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2018, : 378 - 383
  • [6] Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems
    Möritz, M
    Peters, H
    Nipko, B
    Rüden, H
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 203 (5-6) : 401 - 409
  • [7] Cogeneration in modern systems for heating, ventilation, air conditioning and cooling (HVAC)
    Donjerkovic, P
    Petric, H
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2000, 46 (07): : 454 - 465
  • [8] Piezoelectric vibration energy harvesting from airflow in HVAC (Heating Ventilation and Air Conditioning) systems
    Gkoumas, Konstantinos
    Petrini, Francesco
    Bontempi, Franco
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 3444 - 3449
  • [9] Evaluation of operation and control in HVAC (heating, ventilation and air conditioning) system using exergy analysis method
    Du, Zhimin
    Jin, Xinqiao
    Fan, Bo
    ENERGY, 2015, 89 : 372 - 381
  • [10] Mobile Inspection Robot for Heating, Ventilation and Air Conditioning (HVAC) Ducting Systems
    Hisham, Amirah Aisha Badrul
    Xuan, Wong Liang
    Ishak, Mohamad Hafis Izran
    Idris, Nurul Hawani
    Nawi, Abdullah Mohd
    JURNAL TEKNOLOGI, 2015, 73 (06):