Initialization method for the self-calibration using minimal two images

被引:0
|
作者
Ha, JE [1 ]
Kang, DJ [1 ]
机构
[1] Tongmyong Univ Informat Technol, Pusan, South Korea
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Recently, 3D structure recovery through self-calibration of camera has been actively researched. Traditional calibration algorithm requires known 3D coordinates of the control points while self-calibration only requires the corresponding points of images, thus it has more flexibility in real application. In general, self-calibration algorithm results in the nonlinear optimization problem using constraints from the intrinsic parameters of the camera. Thus, it requires initial value for the nonlinear minimization. Traditional approaches get the initial values assuming they have the same intrinsic parameters while they are dealing with the situation where the intrinsic parameters of the camera may change. In this paper, we propose new initialization method using the minimum 2 images. Proposed method is based on the assumption that the least violation of the camera's intrinsic parameter gives more stable initial value. Synthetic and real experiment shows this result.
引用
收藏
页码:915 / 923
页数:9
相关论文
共 50 条
  • [1] Initialization method for self-calibration using 2-views
    Ha, JE
    Kang, DJ
    PATTERN RECOGNITION, 2005, 38 (01) : 143 - 150
  • [2] Sequences Images Based Camera Self-calibration Method
    Jiang, Zetao
    Guo, Shutao
    Jia, Lianggang
    INTELLIGENT SCIENCE AND INTELLIGENT DATA ENGINEERING, ISCIDE 2011, 2012, 7202 : 538 - 545
  • [3] An Online Initialization and Self-Calibration Method for Stereo Visual-Inertial Odometry
    Huang, Weibo
    Liu, Hong
    Wan, Weiwei
    IEEE TRANSACTIONS ON ROBOTICS, 2020, 36 (04) : 1153 - 1170
  • [4] Self-calibration using two same circles
    Da, Feipeng
    Li, Qin
    Zhang, Hu
    Fang, Xu
    OPTICS AND LASER TECHNOLOGY, 2012, 44 (06): : 1924 - 1933
  • [5] Self-calibration using two same circles
    Zhang, Hu
    Da, Feipeng
    Li, Qin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2010, 31 (03): : 618 - 624
  • [6] Stereo-PIV using self-calibration on particle images
    B. Wieneke
    Experiments in Fluids, 2005, 39 : 267 - 280
  • [7] Stereo-PIV using self-calibration on particle images
    Wieneke, B
    EXPERIMENTS IN FLUIDS, 2005, 39 (02) : 267 - 280
  • [8] Self-calibration from one circular motion sequence and two images
    Zhong, H.
    Hung, Y. S.
    PATTERN RECOGNITION, 2006, 39 (09) : 1672 - 1678
  • [9] Correlator self-calibration method
    MontesUsategui, M
    Monroe, SE
    Juday, RD
    OPTICAL PATTERN RECOGNITION VII, 1996, 2752 : 132 - 143
  • [10] Visual servoing method using camera self-calibration
    Lee, Dong-Wook
    Kim, Se-Hoon
    Won, Sang-Chul
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 2649 - +