Operational experience with the CDF Run II silicon detector

被引:2
|
作者
Eusebi, Ricardo [1 ]
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2009年 / 598卷 / 01期
关键词
Silicon; Detector; Vertex; Aging; Radiation damage;
D O I
10.1016/j.nima.2008.08.082
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Collider Detector at Fermilab (CDF) Run II silicon detector is currently the largest operating silicon detector in High Energy Physics. Its 750,000 channels, spread over 6 m(2) of p-on-n silicon sensors, and allow precision tracking of charged particles and vertexing at the 50 mu m level. The CDF Run II silicon detector is fundamental for all branches of the CDF physics program. It played a critical role in the discovery of B(s) mixing and is used extensively for the current Higgs boson searches at the forefront of the energy frontier. Over the last 6 years, the detector efficiency has remained stable above 95% after the Run II commissioning period. While originally designed to withstanding up to 3 fb(-1) of data, the CDF II silicon detector will have to last to the end of Run II where 5-8 fb(-1) of data are expected to be delivered. This letter presents the observed effects of infrastructure aging and the solutions implemented to prevent them. followed by the assessment on radiation damage and expected performance to the end of the Tevatron Run II program. The radiation aging of such a large scale system is particular relevant for future silicon detectors in hadronic colliders as LHC. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 53
页数:4
相关论文
共 50 条
  • [1] Operational experience with the CDF RUN II silicon detector
    Stanitzki, Marcel
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1101 - 1105
  • [2] Operational Experience with the CDF Run II Silicon Detector
    Mathis, Mark
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 745 - 746
  • [3] Operational experience of the CDF1 Run II silicon detector
    Mitra, Ankush
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 273 - 276
  • [4] Aging Effects and Operational Experience with the CDF Run II Silicon Detector
    Husemann, U.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1179 - 1183
  • [5] Operational experience with the CDF Run ll Silicon Detector
    Mondragon, Miguel N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 571 - 572
  • [6] Operational experience, improvements, and performance of the CDF Run II silicon vertex detector
    Aaltonen, T.
    Behari, S.
    Boveia, A.
    Brau, B.
    Bolla, G.
    Bortoletto, D.
    Calancha, C.
    Carron, S.
    Cihangir, S.
    Corbo, M.
    Clark, D.
    Di Ruzza, B.
    Eusebi, R.
    Fernandez, J. P.
    Freeman, J. C.
    Garcia, J. E.
    Garcia-Sciveres, M.
    Glenzinski, D.
    Gonzalez, O.
    Grinstein, S.
    Hartz, M.
    Herndon, M.
    Hill, C.
    Hocker, A.
    Husemann, U.
    Incandela, J.
    Issever, C.
    Jindariani, S.
    Junk, T. R.
    Knoepfel, K.
    Lewis, J. D.
    Lu, R. S.
    Martinez-Ballarin, R.
    Mathis, M.
    Mattson, M.
    Merkel, P.
    Miller, L.
    Mitra, A.
    Mondragon, M. N.
    Moore, R.
    Mumford, J. R.
    Nahn, S.
    Nielsen, J.
    Nelson, T. K.
    Pavlicek, V.
    Pursley, J.
    Redondo, I.
    Roser, R.
    Schultz, K.
    Slaughter, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 729 : 153 - 181
  • [7] Operational experience with the silicon detector at CDF
    Wagner, Jeannine
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01): : 220 - 222
  • [8] The CDF Silicon Detector for Run II
    Fernández, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 535 (1-2): : 370 - 373
  • [9] Status of the CDF run II silicon detector
    Nahn, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 20 - 23
  • [10] The CDF silicon vertex detector for Run II
    Rossin, R
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 288 - 297