Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis

被引:20
|
作者
Mai, Hang-Nga [1 ]
Kim, Jaeil [2 ]
Choi, Youn-Hee [1 ,3 ]
Lee, Du-Hyeong [1 ,4 ]
机构
[1] Kyungpook Natl Univ, Inst Translat Res Dent, Daegu 41940, South Korea
[2] Kyungpook Natl Univ, Sch Comp Sci & Engn, Daegu 41940, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Prevent Dent, Daegu 41940, South Korea
[4] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu 41940, South Korea
关键词
accuracy; three-dimensional face model; portable facial scanning; systematic review; meta-analysis; FACIAL ANATOMY; REPRODUCIBILITY; RELIABILITY; VALIDATION; PHOTOGRAMMETRY;
D O I
10.3390/ijerph18010094
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of three-dimensional face-scanning systems to obtain facial models is of increasing interest, however, systematic assessments of the reliability of portable face-scan devices have not been widely conducted. Therefore, a systematic review and meta-analysis were performed considering the accuracy of facial models obtained by portable face-scanners in comparison with that of those obtained by stationary face-scanning systems. A systematic literature search was conducted in electronic databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for articles published from 1 January 2009 to 18 March 2020. A total of 2806 articles were identified, with 21 articles available for the narrative review and nine studies available for meta-analysis. The meta-analysis revealed that the accuracy of the digital face models generated by the portable scanners was not significantly different from that of the stationary face-scanning systems (standard mean difference (95% confidence interval) = -0.325 mm (-1.186 to 0.536); z = -0.74; p = 0.459). Within the comparison of the portable systems, no statistically significant difference was found concerning the accuracy of the facial models among scanning methods (p = 0.063). Overall, portable face-scan devices can be considered reliable for obtaining facial models. However, caution is needed when applying face-scanners with respect to scanning device settings, control of involuntary facial movements, landmark and facial region identifications, and scanning protocols.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 50 条
  • [1] The Effect of Perioral Scan and Artificial Skin Markers on the Accuracy of Virtual Dentofacial Integration: Stereophotogrammetry Versus Smartphone Three-Dimensional Face-Scanning
    Mai, Hang-Nga
    Lee, Du-Hyeong
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (01) : 1 - 12
  • [2] Registration of three-dimensional face scans with average face models
    Salah, Albert Ali
    Alyuz, Nese
    Akarun, Lale
    JOURNAL OF ELECTRONIC IMAGING, 2008, 17 (01)
  • [3] Three-Dimensional Accuracy and Stability of Personalized Implants in Orthognathic Surgery: A Systematic Review and a Meta-Analysis
    Diaconu, Alexandru
    Holte, Michael Boelstoft
    Berg-Beckhoff, Gabriele
    Pinholt, Else Marie
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [4] Diagnostic Accuracy of Three-Dimensional Endoanal Ultrasound for Anal Fistula: A Systematic Review and Meta-analysis
    Li, Jin
    Chen, Shao-Na
    Lin, Yun-Yong
    Zhu, Zhi-Min
    Ye, Da-Lin
    Chen, Fei
    Qiu, Shao-Dong
    TURKISH JOURNAL OF GASTROENTEROLOGY, 2021, 32 (11): : 913 - 922
  • [5] A Systematic Review and Meta-Analysis of the Effectiveness of Non-Face-to-Face Coaching
    Kim, Yucheon
    Lee, Songyi
    SUSTAINABILITY, 2023, 15 (12)
  • [6] Reliability of optical devices for three-dimensional facial anatomy description: a systematic review and meta-analysis
    Gibelli, D.
    Dolci, C.
    Cappella, A.
    Sforza, C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (08) : 1092 - 1106
  • [7] The Accuracy of Acquiring Heart Rate Variability from Portable Devices: A Systematic Review and Meta-Analysis
    Ward C. Dobbs
    Michael V. Fedewa
    Hayley V. MacDonald
    Clifton J. Holmes
    Zackary S. Cicone
    Daniel J. Plews
    Michael R. Esco
    Sports Medicine, 2019, 49 : 417 - 435
  • [8] The Accuracy of Acquiring Heart Rate Variability from Portable Devices: A Systematic Review and Meta-Analysis
    Dobbs, Ward C.
    Fedewa, Michael V.
    MacDonald, Hayley V.
    Holmes, Clifton J.
    Cicone, Zackary S.
    Plews, Daniel J.
    Esco, Michael R.
    SPORTS MEDICINE, 2019, 49 (03) : 417 - 435
  • [9] The use of Three-Dimensional Printing in Orthopaedics: a Systematic Review and Meta-analysis
    O'Connor, Olivia
    Patel, Reece
    Thahir, Azeem
    Ho, Jamie S. Y.
    Jou, Eric
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (07): : 441 - 456
  • [10] Unveiling the Impact of Three-Dimensional Technology on Rhinoplasty: A Systematic Review and Meta-analysis
    Werathammo, Methini
    Seresirikachorn, Kachorn
    Charoenlux, Prapitphan
    FACIAL PLASTIC SURGERY, 2024,