Retinal thickness in healthy and diabetic subjects measured using optical coherence tomography mapping software

被引:143
|
作者
Massin, P
Erginay, A
Haouchine, B
Ben Mehidi, A
Paques, M
Gaudric, A
机构
[1] Univ Paris 07, Dept Ophthalmol, Hop Lariboisiere, F-75475 Paris 10, France
[2] Univ Paris 07, Dept Ophthalmol, Assistance Publ Hop Paris, F-75475 Paris 10, France
关键词
optical coherence tomography; diabetic retinopathy; macular edema; retinal thickness;
D O I
10.1177/112067210201200205
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To define the normal retinal thickness in healthy subjects using optical coherence tomography (OCT) mapping software and to assess the ability of OCT to detect early macular thickening in diabetic patients. METHODS. Six radial scans centered on the fixation point were done on 60 healthy eyes and 70 eyes of 35 diabetic patients without macular edema on biomicroscopy. Retinal thickness was measured automatically with OCT mapping software. Mean retinal thickness was compared in subgroups of healthy patients based on age, sex, and eye, and in the eyes of diabetic patients and healthy subjects. Thickening was diagnosed if mean retinal thickness of an area was greater than the mean thickness + 2SD in the corresponding area in healthy subjects; or if the difference between right and left eye exceeded the mean difference + 2 SD in a given area in healthy subjects. RESULTS. In healthy subjects, mean retinal thickness in the central macular area 1000 mum in diameter was 170 +/- 18 mum. There was no significant difference according to age, or left or right eye, but central macular thickness was significantly greater in men than women (p=0.0139). No difference was observed between the eyes of healthy subjects and diabetic patients without macular edema on biomicroscopy, but OCT detected early macular thickening in 12 diabetic eyes. CONCLUSIONS. In this study average retinal thickness and mean local variations in a normal population were defined using a commercially available mapping software. OCT seems a sensitive tool for detecting early retinal thickening.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 50 条
  • [1] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [2] Thickness and birefringence of retinal nerve fiber layer of healthy and glaucomatous subjects measured with polarization sensitive optical coherence tomography
    Cense, B
    Chen, T
    Park, BH
    Pierce, MC
    de Boer, JF
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 179 - 187
  • [3] Relationship Between Retinal Perfusion and Retinal Thickness in Healthy Subjects: An Optical Coherence Tomography Angiography Study
    Yu, Jian
    Gu, Ruiping
    Zong, Yuan
    Xu, Huan
    Wang, Xiaolei
    Sun, Xinghuai
    Jiang, Chunhui
    Xie, Bing
    Jia, Yali
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT204 - OCT210
  • [4] Retinal nerve fiber layer thickness in a healthy Turkish population measured by optical coherence tomography
    Cubuk, Mehmet
    Sahinoglu-Keskek, Nedime
    Keskek, Sakir Ozgur
    ANNALS OF SAUDI MEDICINE, 2016, 36 (06) : 409 - 413
  • [5] Alterations of retinal thickness measured by optical coherence tomography correlate with neurophysiological measures in diabetic polyneuropathy
    Yamada, Yuichiro
    Himeno, Tatsuhito
    Tsuboi, Kotaro
    Shibata, Yuka
    Kawai, Miyuka
    Asada-Yamada, Yuriko
    Hayashi, Yusuke
    Asano-Hayami, Emi
    Hayami, Tomohide
    Ishida, Yuichiro
    Ejima, Yohei
    Motegi, Mikio
    Asano, Saeko
    Kato, Makoto
    Nagao, Eriko
    Nakai-Shimoda, Hiromi
    Ishikawa, Takahiro
    Morishita, Yoshiaki
    Kondo, Masaki
    Tsunekawa, Shin
    Kato, Yoshiro
    Nakayama, Takayuki
    Kamei, Motohiro
    Nakamura, Jiro
    Kamiya, Hideki
    JOURNAL OF DIABETES INVESTIGATION, 2021, 12 (08) : 1430 - 1441
  • [6] CHOROIDAL THICKNESS IN HEALTHY HISPANIC SUBJECTS MEASURED BY ENHANCED DEPHT IMAGING OPTICAL COHERENCE TOMOGRAPHY
    Sardi Correa, Carolina
    Acosta, Claudia
    Sanchez, Juan
    Rodriguez, Ana
    Gutierrez, Aura
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [7] Retinal thickness in diabetic retinopathy - A study using optical coherence tomography (OCT)
    Goebel, W
    Kretzchmar-Gross, T
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2002, 22 (06): : 759 - 767
  • [8] Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    Neubauer, AS
    Priglinger, S
    Ullrich, S
    Bechmann, M
    Thiel, MJ
    Ulbig, MW
    Kampik, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 596 - 601
  • [9] Corneal and epithelial thickness mapping in diabetic patients using optical coherence tomography
    Twaab, Menna A. M. Abdel
    el Gendy, Heba
    El-Sayed, Mohamed M.
    Arfeen, Shaimaa A.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 22 - 27
  • [10] Peripapillary retinal nerve fibre layer thickness profile in subjects with myopia measured using the Stratus optical coherence tomography
    Kim, M. J.
    Lee, E. J.
    Kim, T-W
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) : 115 - 120