Establishment of degrees of equivalence of national primary standards for absorbed dose to water in accelerator photon beams

被引:0
|
作者
Picard, Susanne [1 ]
Burns, David T. [1 ]
Arcos, Jose Maria Los [1 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
关键词
D O I
10.1088/0026-1394/50/1A/06016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The basis for the degrees of equivalence of national primary standards for absorbed dose to water in accelerator photon beams established by the BIPM.RI(I)-K6 comparison was adopted by the Consultative Committee for Ionizing Radiation in May 2013. The degrees of equivalence for the comparisons with reports published or having reached a draft B stage before the adoption in May 2013 have been determined and are presented. Comparison reports published after that date will each contain the established degrees of equivalence including those for the new comparison.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for accelerator photon beams
    Picard, S.
    Burns, D. T.
    Roger, P.
    Allisy-Roberts, P. J.
    McEwen, M. R.
    Cojocaru, C. D.
    Ross, C. K.
    METROLOGIA, 2010, 47
  • [2] Comparison of the standards for absorbed dose to water of the IAEA and the KRISS, Korea in accelerator photon beams
    Czap, L.
    Kim, I. J.
    Park, J. I.
    Yi, C. -Y.
    Kim, Y.
    Msimang, Z.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (07) : 2698 - 2703
  • [3] The equivalence of the absorbed dose to water in high energy photon beams
    Stancu, E.
    Kapsch, R-P.
    Badita, E. S.
    Scarlat, F.
    Scarisoreanu, A. M.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2018, 12 (3-4): : 237 - 239
  • [4] Primary standards of absorbed dose for electron beams
    McEwen, M. R.
    DuSautoy, A. R.
    METROLOGIA, 2009, 46 (02) : S59 - S79
  • [5] Dosimetry of high-energy photon beams based on standards of absorbed dose to water
    McDonald, JC
    HEALTH PHYSICS, 2002, 82 (05): : 751 - 752
  • [6] Photon absorbed dose standards
    Seuntjens, Jan
    Duane, Simon
    METROLOGIA, 2009, 46 (02) : S39 - S58
  • [7] COMPARISON OF THE NMIJ AND THE ARPANSA STANDARDS FOR ABSORBED DOSE TO WATER IN HIGH-ENERGY PHOTON BEAMS
    Shimizu, M.
    Morishita, Y.
    Kato, M.
    Tanaka, T.
    Kurosawa, T.
    Takata, N.
    Saito, N.
    Ramanathan, G.
    Harty, P. D.
    Oliver, C.
    Wright, T.
    Butler, D. J.
    RADIATION PROTECTION DOSIMETRY, 2015, 164 (03) : 181 - 186
  • [8] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the NRC, Canada and the BIPM in accelerator photon beams
    Kessler C.
    Burns D.T.
    Roger P.
    Muir B.
    McEwen M.
    Metrologia, 2022, 59 (1A)
  • [9] Comparison of the standards for absorbed dose to water of the METAS, Switzerland and the BIPM in accelerator photon beams (BIPM.RI(I)-K6)
    Kessler, C.
    Burns, D. T.
    Roger, P.
    Kottler, C.
    Voros, S.
    Peier, P.
    METROLOGIA, 2019, 56 (1A)
  • [10] Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the PTB, Germany, and the BIPM, in accelerator photon beams
    Kessler C.
    Burns D.T.
    Roger P.
    Krauss A.
    Kapsch R.-P.
    Metrologia, 2022, 59 (1 A)