Characterization of Patient Dose Distribution and Probabilistic Risk Analysis in Cardiac Catheterization Laboratories

被引:0
|
作者
Weir, V. [1 ]
Zhang, J. [2 ]
Khan, M. [1 ]
机构
[1] Dept Vet Affairs, New York, NY USA
[2] Univ Kentucky, Lexington, KY USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-I-
引用
收藏
页码:E665 / E665
页数:1
相关论文
共 50 条
  • [1] Characterization of patient dose distributions and probabilistic risk analysis in cardiovascular catheterization laboratories
    Weir, Victor J.
    Zhang, Jie
    Khan, M. Rehan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [2] Analysis and consideration of radiation dose distribution in cardiac catheterization interventions
    You, Z.
    Liu, Y.
    Li, C.
    Hu, A.
    Liu, X.
    Li, W.
    Liao, L.
    Liu, F.
    RADIOPROTECTION, 2025, 60 (01) : 20 - 27
  • [3] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    CIRCULATION, 2005, 111 (01) : 83 - 89
  • [4] Benchmarking cardiac catheterization laboratories: The impact of patient age, gender and risk factors on variable costs, device costs, total time and procedural time in 53 catheterization laboratories
    Becker, ER
    Cohen, D
    Culler, SD
    Ellis, S
    Green, LM
    Schnitzler, RN
    Simon, A
    Weintraub, WS
    JOURNAL OF INVASIVE CARDIOLOGY, 1999, 11 (09): : 533 - 542
  • [5] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [6] Estimation of radiation exposure and radiation risk to staff of cardiac catheterization laboratories
    Folkerts, KH
    Munz, A
    Jung, S
    ZEITSCHRIFT FUR KARDIOLOGIE, 1997, 86 (04): : 258 - 263
  • [7] Impact at patient characteristics, complications, and facility volume on the casts and time of cardiac catheterization and coronary angioplasty in 70 catheterization laboratories
    Cohen, DJ
    Becker, ER
    Culler, SD
    Ellis, S
    Green, LM
    Schnitzler, RN
    Simon, AW
    Weintraub, WS
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (06): : 595 - 601
  • [8] A mathematical model for patient skin dose assessment in cardiac catheterization procedures
    Morrell, R. E.
    Rogers, A. T.
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (945): : 756 - 761
  • [9] Radiation Dose Surveillance Using Automated, Remote-site Dose Monitoring In Cardiac Catheterization Laboratories Across Asia Pacific
    Arasaratnam, Punitha
    Low, Wilson
    Hwa, Ho Hee
    Felix, Cecilia
    Beri, Nandita
    Htike, Aung Than
    Foo, David
    Ong, Paul
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B89 - B89
  • [10] Characteristics Associated With Reduced Patient Radiation Dose in an Academic Cardiac Catheterization Lab
    Mann, Steve
    Green, Cynthia
    Russ, Megan
    Wei, Trent
    Patel, Manesh
    Tcheng, James
    Rao, Sunil
    Jones, Schuyler
    Wegermann, Zachary
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B80 - B80