Analysis of diclofenac in water samples using in situ derivatization-vortex-assisted liquid-liquid microextraction with gas chromatography-mass spectrometry

被引:9
|
作者
Aydin, Senar [1 ]
Aydin, Mehmet Emin [1 ]
Beduk, Fatma [1 ]
Tekinay, Arzu [1 ]
Kilic, Havva [1 ]
机构
[1] Necmettin Erbakan Univ, Environm Engn Dept, Konya, Turkey
关键词
diclofenac; GC-MS; in situ derivatization; vortex-assisted liquid-liquid micro-extraction; water; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; SOLID-PHASE EXTRACTION; SEWAGE-TREATMENT PLANTS; WASTE-WATER; ACIDIC PHARMACEUTICALS; AQUATIC ENVIRONMENT; RISK-ASSESSMENT; GC-MS; WASTEWATERS; PRODUCTS;
D O I
10.2478/acph-2018-0024
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A novel micro-extraction technique for a rapid and sensitive analysis of diclofenac (DCF) in water samples has been developed. DCF was derivatized and extracted simultaneously using vortex-assisted liquid-liquid micro-extraction (VALLME) prior to gas chromatography with mass spectrometry detection. The effects of extraction solvent volume, extraction and derivatization time and ionic strength of the sample were studied using 2(3) factorial experimental design. The optimum extraction conditions were as follows: 200 mu L of chloroform, 25 mu L of N-methyl-N-trimethylsilyl- trifluoroacetamide (MSTFA) derivatization reagent, vortex extraction and derivatization time 5 min at 3000 rpm. The extraction recovery for different fortification levels was 98 %. Also, the proposed micro-extraction method - exhibited results comparable with the solid phase extraction of real water samples. The proposed one-step VALLME and derivatization method is simpler and faster than the conventional extraction and derivatization methods used for the determination of DCF in real water samples.
引用
收藏
页码:313 / 324
页数:12
相关论文
共 50 条
  • [1] Determination of ultraviolet filters in water samples by vortex-assisted dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
    Zhang, Yufeng
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1249 : 25 - 31
  • [2] Determination of benzotriazoles in water samples by concurrent derivatization-dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometry
    Casado, J.
    Nescatelli, R.
    Rodriguez, I.
    Ramil, M.
    Marini, F.
    Cela, R.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 : 1 - 9
  • [3] Vortex-assisted liquid-liquid microextraction combined with gas chromatography-mass spectrometry for the determination of organophosphate pesticides in environmental water samples and wines
    Zacharis, Constantinos K.
    Christophoridis, Christophoros
    Fytianos, Konstantinos
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (18) : 2422 - 2429
  • [4] Determination of nitrobenzenes and nitrochlorobenzenes in water samples using dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry
    Zhang, Delin
    Zeng, Xiangying
    Yu, Zhiqiang
    Sheng, Guoying
    Fu, Jiamo
    ANALYTICAL METHODS, 2011, 3 (10) : 2254 - 2260
  • [5] Determination of organophosphorus pesticides in wastewater samples using vortex-assisted dispersive liquid-liquid microextraction with liquid chromatography-mass spectrometry
    Muckoya, V. A.
    Nomngongo, P. N.
    Ngila, J. C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (04) : 2325 - 2336
  • [6] Fast screening of perfluorooctane sulfonate in water using vortex-assisted liquid-liquid microextraction coupled to liquid chromatography-mass spectrometry
    Papadopoulou, Aikaterini
    Roman, Ivan P.
    Canals, Antonio
    Tyrovola, Konstantina
    Psillakis, Elefteria
    ANALYTICA CHIMICA ACTA, 2011, 691 (1-2) : 56 - 61
  • [7] Analyses of polychlorinated biphenyls in waters and wastewaters using vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry
    Ozcan, Senar
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (05) : 574 - 584
  • [8] Determination of organochlorine pesticides in water samples by dispersive liquid-liquid microextraction coupled to gas chromatography-mass spectrometry
    Cortada, Carol
    Vidal, Lorena
    Pastor, Raul
    Santiago, Noemi
    Canals, Antonio
    ANALYTICA CHIMICA ACTA, 2009, 649 (02) : 218 - 221
  • [9] Improvement and validation the method using dispersive liquid-liquid microextraction with in situ derivatization followed by gas chromatography-mass spectrometry for determination of tricyclic antidepressants in human urine samples
    Ito, Rie
    Ushiro, Masaru
    Takahashi, Yuki
    Saito, Koichi
    Ookubo, Tetsuo
    Iwasaki, Yusuke
    Nakazawa, Hiroyuki
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (31): : 3714 - 3720
  • [10] Determination of chlorobenzenes in textiles by pressurized hot water extraction followed by vortex-assisted liquid-liquid microextraction and gas chromatography-mass spectrometry
    Lu, Yang
    Zhu, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1319 : 27 - 34