The analysis of thyroxine in human serum by an 'exact matching' isotope dilution method with liquid chromatography/tandem mass spectrometry

被引:36
|
作者
Hopley, CJ
Stokes, P
Webb, KS
Baynham, M
机构
[1] Lab Govt Chemist, Teddington TW11 0LY, Middx, England
[2] Appl Biosyst Inc, Warrington WA3 7QH, Cheshire, England
关键词
D O I
10.1002/rcm.1441
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the analysis of thyroxine in human serum, utilising 'exact matching' isotope dilution mass spectrometry (IDMS) in combination with liquid chromatography/tandem mass spectrometry (LC/MS/MS), has been developed with a limit of quantification of 0.5 ng g(-1) of thyroxine in human serum. The extraction and clean-up of thyroxine from serum involves an efficient protein-precipitation stage followed by a solid-phase extraction procedure to produce an extract essentially free from interfering compounds. The method is reproducible, with expanded uncertainties of less than 2%, and is relatively fast to perform. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1033 / 1038
页数:6
相关论文
共 50 条
  • [1] Determination of phenylalanine in human serum by isotope dilution liquid chromatography/tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Lee, Gaeho
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1913 - 1917
  • [2] Stable isotope-dilution liquid chromatography/tandem mass spectrometry method for determination of thyroxine in saliva
    Higashi, Tatsuya
    Ichikawa, Takuya
    Shimizu, Chikara
    Nagai, So
    Inagaki, Shinsuke
    Min, Jun Zhe
    Chiba, Hitoshi
    Ikegawa, Shigeo
    Toyo'oka, Toshimasa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 1013 - 1017
  • [3] Serum cholesterol measured by isotope dilution liquid chromatography tandem mass spectrometry
    Zhou, Weiyan
    Li, Hongxia
    Dong, Jun
    Wang, Shu
    Yang, Ruiyue
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (04) : 669 - 676
  • [4] High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry
    Chen, Yizhao
    Liu, Qinde
    Yong, Sharon
    Lee, Tong Kooi
    CLINICA CHIMICA ACTA, 2012, 413 (7-8) : 808 - 813
  • [5] Isotope dilution-liquid chromatography electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method
    De Brabandere, VI
    Hou, P
    Stockl, D
    Thienpont, LM
    De Leenheer, AP
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (16) : 1099 - 1103
  • [6] Sensitive isotope dilution liquid chromatography/tandem mass spectrometry method for quantitative analysis of bumetanide in serum and brain tissue
    Li, Yijun
    Cleary, Ryan
    Kellogg, Mark
    Soul, Janet S.
    Berry, Gerard T.
    Jensen, Frances E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 998 - 1002
  • [7] Detection of SERUM testosterone by liquid chromatography-isotope dilution tandem mass spectrometry
    Chen, Y.
    Yazdanpanah, M.
    Hoffman, Barry
    Diamandis, E. P.
    Wong, P. Y.
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1266 - 1266
  • [8] Analysis of pharmaceuticals in water by isotope dilution liquid chromatography/tandem mass spectrometry
    Vanderford, Brett J.
    Snyder, Shane A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2006, 40 (23) : 7312 - 7320
  • [9] Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry
    Tai, SSC
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2004, 76 (04) : 1008 - 1014
  • [10] Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry Candidate Reference Method for Total Testosterone in Human Serum
    Botelho, Julianne Cook
    Shacklady, Christopher
    Cooper, Hans C.
    Tai, Susan S. -C.
    Van Uytfanghe, Katleen
    Thienpont, Linda M.
    Vesper, Hubert W.
    CLINICAL CHEMISTRY, 2013, 59 (02) : 372 - 380