共 25 条
A process analytical technology approach for the production of fixed-dose combination tablets of zidovudine and lamivudine using near infrared spectroscopy and chemical images
被引:9
|作者:
Grangeiro Junior, Severino
[1
,4
]
Franca, Leandro de Moura
[2
]
Pimentel, Maria Femanda
[3
]
Albuquerque, Miracy Muniz
[1
]
de Santana, Davi Pereira
[1
]
Santana, Aila Karla M.
[4
]
Souza, Julia Aparecida L.
[1
]
Simoes, Simone S.
[5
]
机构:
[1] Univ Fed Pernambuco, Dept Ciencias Farmaceut, Recife, PE, Brazil
[2] Univ Fed Pernambuco, Dept Quim Fundamental, Recife, PE, Brazil
[3] Univ Fed Pernambuco, Dept Engn Quim, Recife, PE, Brazil
[4] Lab Farmaceut Estado Pernambuco, Recife, PE, Brazil
[5] Univ Estadual Paraiba, Dept Quim, Campina Grande, PB, Brazil
关键词:
PAT;
NIR;
Chemical image;
Zidovudine;
Lamivudine;
Quality control;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
MULTIVARIATE CALIBRATION;
PHARMACEUTICAL FORMULATIONS;
CONTENT UNIFORMITY;
NIR;
CHEMOMETRICS;
VALIDATION;
NEVIRAPINE;
STAVUDINE;
STRATEGY;
D O I:
10.1016/j.microc.2014.07.009
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The production of solid drugs generally consists of several steps, which are monitored using quality control assays. In this work, rapid and non-destructive methods, which conform to the principles of the process analytical technology (PAT) framework, were developed for monitoring the production affixed-dose combination tablets of zidovudine (AZT) and lamivudine (3TC). NIR spectroscopy was employed to determine the content of AZT and 3TC at three different steps of production: in the granulate material, in the core and in the manufactured tablet. NIR chemical images (NIR-CI) were used as a complementary study to evaluate the chemical distribution on the uncoated tablet surfaces, and its internal correlation structures. NIR methods for monitoring the moisture content in the granulate material and the hardness of the tablets before the coating step were also developed. A comparison between two multivariate calibration techniques: PLS and MLR was carried out. The models showed accurate results and prediction errors below those allowed by the regulatory agencies. Through the concentration maps associated with multivariate analysis, the internal chemical structure of API distribution and the excipient increased the understanding of the mixing process, allowing for further improvements. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:252 / 258
页数:7