The New CLOCIT Irradiation Facility for 40Ar/39Ar Geochronology: Characterisation, Comparison with CLICIT and Implications for High-Precision Geochronology
被引:12
|作者:
Rutte, Daniel
[1
,2
]
Becker, Tim A.
[1
]
Deino, Alan L.
[1
]
Reese, Steven R.
[3
]
Renne, Paul R.
[1
,2
]
Schickler, Robert A.
[3
]
机构:
[1] Berkeley Geochronol Ctr, Berkeley, CA 94709 USA
[2] Univ Calif Berkeley, Dept Earth & Planetary Sci, Berkeley, CA 94720 USA
[3] Oregon State Univ, Nucl Sci & Engn, Corvallis, OR 97331 USA
基金:
美国国家科学基金会;
关键词:
Ar-Ar dating;
geochronology;
reference materials;
argon isotopes;
neutron fluence gradient;
nuclear reactions;
research reactor;
AGE;
D O I:
10.1111/ggr.12217
中图分类号:
P3 [地球物理学];
P59 [地球化学];
学科分类号:
0708 ;
070902 ;
摘要:
The Cadmium-Lined Outer-Core Irradiation Tube (CLOCIT) is a new irradiation facility for 40Ar/39Ar geochronology at the Oregon State University TRIGA((R)) reactor. We report fluence (i.e., time-integrated flux) parameters from the first four CLOCIT irradiations and compare them with the existing Cadmium-Lined Inner-Core Irradiation Tube (CLICIT). CLOCIT provides an average neutron flux equivalent of 1.45-1.53x10(-4)Jh(-1); about 55% of CLICIT. Radial fluence gradients were on the order of 0.2-4.2% cm(-1). A planar fit of J-values results in residuals in the range of uncertainty in the J-value, but systematic deviations resolve a non-planar component of the neutron flux field, which has also been observed in CLICIT. Axial neutron fluence gradients were 0.6-1% cm(-1), compared with 0.7-1.6% cm(-1) for the CLICIT. Production rate ratios of interfering reactions were (40Ar/39Ar)(K)=(4 +/- 6)x10(-4) and (Ar-38/39Ar)(K)=(1.208 +/- 0.002)x10(-2), (Ar-36/Ar-37)(Ca)= (2.649 +/- 0.014) x 10(-4), (Ar-38/Ar-37)(Ca)= (3.33 +/- 0.12) x 10(-5) and (39Ar/Ar-37)(Ca)= (9.1 +/- 0.28) x 10(-4), similar to the CLICIT values.
引用
收藏
页码:301 / 307
页数:7
相关论文