Objective, observer-independent evaluation of myocardial perfusion and function: role of SPECT

被引:1
|
作者
Szot, Wojciech [1 ]
Kwiecien, Ewa [2 ]
Tekieli, Lukasz [2 ,3 ]
Czyz, Lukasz [2 ]
Borkowska, Eliza [1 ]
Dabrowski, Wladyslaw [3 ]
Drabik, Leszek [2 ,4 ]
Dabrowski, Maciej [5 ]
Kostkiewicz, Magdalena [1 ,2 ]
Musialek, Piotr [2 ]
机构
[1] John Paul 2 Hosp, Nucl Imaging Lab, Krakow, Poland
[2] Jagiellonian Univ, John Paul II Hosp, Dept Cardiac & Vasc Dis, Krakow, Poland
[3] Jagiellonian Univ, John Paul II Hosp, Dept Intervent Cardiol, Krakow, Poland
[4] Jagiellonian Univ Med Coll, Dept Pharmacol, Krakow, Poland
[5] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2022年 / 18卷 / 04期
关键词
SPECT; ischaemic heart failure; independent evaluation; myocardial perfusion; myocardial function; LEFT-VENTRICULAR VOLUMES; GATED TC-99M-MIBI SPECT; EJECTION FRACTION; PROGNOSTIC VALUE; CONTRAST ECHOCARDIOGRAPHY; VIABILITY; TRIAL; INFARCTION; ACCURACY; ANEURYSM;
D O I
10.5114/aic.2023.124045
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The number of patients with coronary artery disease and ischaemic heart failure - and those with terminal heart failure - is increasing despite improvements in medical and interventional therapies of ischaemic heart disease - and, over the next decades, it is projected to continue to increase further. Observer-independent, reproducible imaging techniques play a fundamental role in objective evaluation of both conventional (such as surgical or percutaneous) myocardial revascularization and novel therapeutic approaches to reduce myocardial ischaemia, improve contractility and prevent adverse myocardial remodelling. To be applicable to clinical practice, the clinical study design and data should best be rooted in everyday clinical practice. Accurate and reproducible assessment of left ventricular ejection fraction, left ventricular volumes, myocardial perfusion and function is one of the most important objectives of cardiac imaging. Current techniques used both in clinical studies and in everyday clinical practice include 2- and 3-dimensional echocardiography, magnetic resonance imaging, single-photon emission computed tomography and positron emission tomography; each of these has its strengths and limitations. We review present evidence on the role of single-photon emission computed tomography as a technique that may offer, through being observer-independent, the most objective evaluation of evolution of left ventricular perfusion, volumes and ejection fraction.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 50 条
  • [1] Clinical testing of an optimized software solution for an automated, observer-independent evaluation of dopamine transporter SPECT studies
    Koch, W
    Radau, PE
    Hamann, C
    Tatsch, K
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (07) : 1109 - 1118
  • [2] Clinical testing of an optimized software solution for an automated, observer-independent evaluation of dopamine transporter SPECT studies.
    Koch, W
    Hamann, C
    Radau, P
    Tatsch, K
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 255P - 255P
  • [3] Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
    Fard-Esfahani, Armaghan
    Fallahi, Babak
    Mirpour, Sahar
    Gholamrezanezhad, Ali
    Abdi, Ezatollah
    Karimi, Mohammad
    Beiki, Davood
    Emami-Ardekani, Alireza
    Akhzari, Fariba
    Ansari, Mojtaba
    Eftekhari, Mohammad
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2012, 20 (02): : 20 - 24
  • [5] Evaluation of accuracy of maxillary repositioning surgery using an observer-independent method
    Koseki, Rieko
    Suzuki, Kenji
    Ozawa, Shigeyuki
    Ikoma, Takeharu
    Kanamori, Keisuke
    Fushima, Kenji
    Kobayashi, Masaru
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2024, 36 (03) : 315 - 322
  • [6] Evaluation of myocardial perfusion and function by gated SPECT in patients with Behcet's disease
    Kaya, Eser
    Saglam, Hayrettin
    Ciftci, Ismail
    Kulac, Mustafa
    Karaca, Semsettin
    Melek, Mehmet
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (04) : 287 - 295
  • [7] Evaluation of carbonmonoxide cardiotoxicity with myocardial perfusion SPECT
    Entok, E
    Cavusoglu, Y
    Birdane, A
    Vardareli, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S305 - S305
  • [8] Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT
    Xu, Yuan
    Hayes, Sean
    Ali, Iftikhar
    Ruddy, Terrence
    Wells, R. Glenn
    Berman, Daniel
    Germano, Guido
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [9] Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT
    Yuan Xu
    Sean Hayes
    Iftikhar Ali
    Terrence D. Ruddy
    R. Glenn Wells
    Daniel S. Berman
    Guido Germano
    Piotr J. Slomka
    Journal of Nuclear Cardiology, 2010, 17 : 1050 - 1057
  • [10] Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT
    Xu, Yuan
    Hayes, Sean
    Ali, Iftikhar
    Ruddy, Terrence D.
    Wells, R. Glenn
    Berman, Daniel S.
    Germano, Guido
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2010, 17 (06) : 1050 - 1057