Comparison of Biophysical Factors Influencing on Emphysema Quantification with Low-dose CT

被引:0
|
作者
Heo, Chang Yong [1 ]
Kim, Jong Hyo [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Interdisciplinary Program Radiat Appl Life Sci, Seoul, South Korea
关键词
Emphysema; Quantification; Biophysical factor; Low-dose CT; Lung; CAD; PULMONARY-EMPHYSEMA; COMPUTED-TOMOGRAPHY; LUNG DENSITOMETRY; BODY CT; MORPHOMETRY; PROGRESSION; SMOKERS; COPD;
D O I
10.1117/12.2043894
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Emphysema Index(EI) measurements in MDCT is known to be influenced by various biophysical factors such as total lung volume, and body size. We investigated the association of the four biophysical factors with emphysema index in low-dose MDCT. In particular, we attempted to identify a potentially stronger biophysical factor than total lung volume. A total of 400 low-dose MDCT volumes taken at 120kVp, 40mAs, 1mm thickness, and B30f reconstruction kernel were used. The lungs, airways, and pulmonary vessels were automatically segmented, and two Emphysema Indices, relative area below -950HU(RA950) and 15th percentile(Perc15), were extracted from the segmented lungs. The biophysical factors such as total lung volume(TLV), mode of lung attenuation(ModLA), effective body diameter(EBD), and the water equivalent body diameter(WBD) were estimated from the segmented lung and body area. The association of biophysical factors with emphysema indices were evaluated by correlation coefficients. The mean emphysema indices were 8.3 +/- 5.5(%) in RA950, and -930 +/- 18(HU) in Perc15. The estimates of biophysical factors were 4.7 +/- 1.0(L) in TLV, -901 +/- 21(HU) in ModLA, 26.9 +/- 2.2(cm) in EBD, and 25.9 +/- 2.6(cm) in WBD. The correlation coefficients of biophysical factors with RA950 were 0.73 in TLV, 0.94 in ModLA, 0.31 in EBD, and 0.18 WBD, the ones with Perc15 were 0.74 in TLV, 0.98 in ModLA, 0.29 in EBD, and 0.15 WBD. Study results revealed that two biophysical factors, TLV and ModLA, mostly affects the emphysema indices. In particular, the ModLA exhibited strongest correlation of 0.98 with Perc15, which indicating the ModLA is the most significant confounding biophysical factor in emphysema indices measurement.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Optimal threshold in low-dose CT quantification of emphysema
    Cao, Xianxian
    Jin, Chenwang
    Tan, Tao
    Guo, Youmin
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 129
  • [2] QUANTIFICATION OF EMPHYSEMA USING LOW-DOSE CHEST CT: EFFECT OF ITERATIVE RECONSTRUCTION
    Park, K. J.
    Cho, J. Y.
    RESPIRATORY MEDICINE, 2017, 132 : 274 - 274
  • [3] Comparison of standard- and low-radiation-dose CT for quantification of emphysema
    Gierada, David S.
    Pilgram, Thomas K.
    Whiting, Bruce R.
    Hong, Cheng
    Bierhals, Andrew J.
    Kim, Jin Hwan
    Bae, Kyongtae T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (01) : 42 - 47
  • [4] Volumetric assessment of emphysema on low-dose screening CT scans
    Kostis, WJ
    Fluture, SC
    Farooqi, AO
    Yankelevitz, DF
    Henschke, CI
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 827 - 834
  • [5] Emphysema quantification using low-dose computed tomography with deep learning–based kernel conversion comparison
    So Hyeon Bak
    Jong Hyo Kim
    Hyeongmin Jin
    Sung Ok Kwon
    Bom Kim
    Yoon Ki Cha
    Woo Jin Kim
    European Radiology, 2020, 30 : 6779 - 6787
  • [6] Emphysema Quantification by Low-Dose CT: Potential Impact of Adaptive Iterative Dose Reduction Using 3D Processing
    Nishio, Mizuho
    Matsumoto, Sumiaki
    Ohno, Yoshiharu
    Sugihara, Naoki
    Inokawa, Hiroyasu
    Yoshikawa, Takeshi
    Sugimura, Kazuro
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (03) : 595 - 601
  • [7] Robust, Standardized Quantification of Pulmonary Emphysema in Low Dose CT Exams
    Ceresa, Mario
    Bastarrika, Gorka
    de Torres, Juan P.
    Montuenga, Luis M.
    Zulueta, Javier J.
    Ortiz-de-Solorzano, Carlos
    Munoz-Barrutia, Arrate
    ACADEMIC RADIOLOGY, 2011, 18 (11) : 1382 - 1390
  • [8] Deep learning-enabled accurate normalization of reconstruction kernel effects on emphysema quantification in low-dose CT
    Jin, Hyeongmin
    Heo, Changyong
    Kim, Jong Hyo
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (13):
  • [9] Factors Influencing Effects of Low-dose Radiation Exposure
    Mothersill, Carmel
    Seymour, Colin
    Cocchetto, Alan
    Williams, David
    HEALTH PHYSICS, 2024, 126 (05): : 296 - 308
  • [10] Local noise reduction for emphysema scoring in low-dose CT images
    Schilham, A
    Prokop, M
    Gietema, H
    van Ginneken, B
    Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 921 - 929