Moment Measurements in Dynamic and Quasi-Static Spine Segment Testing Using Eccentric Compression are Susceptible to Artifacts Based on Loading Configuration

被引:1
|
作者
Van Toen, Carolyn [1 ,2 ,3 ]
Carter, Jarrod W. [4 ]
Oxland, Thomas R. [1 ,2 ,3 ]
Cripton, Peter A. [5 ,6 ,7 ]
机构
[1] Univ British Columbia, Dept Mech Engn, Orthopaed & Injury Biomech Grp, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Orthopaed, Orthopaed & Injury Biomech Grp, Vancouver, BC V5Z 1M9, Canada
[3] Univ British Columbia, ICORD, Vancouver, BC V5Z 1M9, Canada
[4] Origin Engn LLC, Liberty Lake, WA 99019 USA
[5] Univ British Columbia, Dept Mech Engn, Orthopaed & Injury Biomech Grp, Vancouver, BC V6T 1Z4, Canada
[6] Univ British Columbia, Dept Orthopaed, Orthopaed & Injury Biomech Grp, Vancouver, BC V6T 1Z4, Canada
[7] Univ British Columbia, Dept Orthopaed, ICORD, Vancouver, BC V6T 1Z4, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
spine; bending moment; test apparatus; artifact; dynamic; cadaver; IN-VITRO; CERVICAL-SPINE; FIXATION DEVICES; BIOMECHANICAL EVALUATION; STRUCTURAL-PROPERTIES; FLEXION; STABILIZATION; EXTENSION; STABILITY; STRENGTHS;
D O I
10.1115/1.4028817
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The tolerance of the spine to bending moments, used for evaluation of injury prevention devices, is often determined through eccentric axial compression experiments using segments of the cadaver spine. Preliminary experiments in our laboratory demonstrated that eccentric axial compression resulted in "unexpected" (artifact) moments. The aim of this study was to evaluate the static and dynamic effects of test configuration on bending moments during eccentric axial compression typical in cadaver spine segment testing. Specific objectives were to create dynamic equilibrium equations for the loads measured inferior to the specimen, experimentally verify these equations, and compare moment responses from various test configurations using synthetic (rubber) and human cadaver specimens. The equilibrium equations were verified by performing quasi-static (5 mm/s) and dynamic experiments (0.4 m/s) on a rubber specimen and comparing calculated shear forces and bending moments to those measured using a six-axis load cell. Moment responses were compared for hinge joint, linear slider and hinge joint, and roller joint configurations tested at quasi-static and dynamic rates. Calculated shear force and bending moment curves had similar shapes to those measured. Calculated values in the first local minima differed from those measured by 3% and 15%, respectively, in the dynamic test, and these occurred within 1.5 ms of those measured. In the rubber specimen experiments, for the hinge joint (translation constrained), quasi-static and dynamic posterior eccentric compression resulted in flexion (unexpected) moments. For the slider and hinge joints and the roller joints (translation unconstrained), extension ("expected") moments were measured quasi-statically and initial flexion (unexpected) moments were measured dynamically. In the cadaver experiments with roller joints, anterior and posterior eccentricities resulted in extension moments, which were unexpected and expected, for those configurations, respectively. The unexpected moments were due to the inertia of the superior mounting structures. This study has shown that eccentric axial compression produces unexpected moments due to translation constraints at all loading rates and due to the inertia of the superior mounting structures in dynamic experiments. It may be incorrect to assume that bending moments are equal to the product of compression force and eccentricity, particularly where the test configuration involves translational constraints and where the experiments are dynamic. In order to reduce inertial moment artifacts, the mass, and moment of inertia of any loading jig structures that rotate with the specimen should be minimized. Also, the distance between these structures and the load cell should be reduced.
引用
收藏
页数:7
相关论文
共 46 条
  • [1] Compression Tests of Polycarbonate under Quasi-static and Dynamic Loading
    Hu, Wenjun
    Huang, Xicheng
    Zhang, Fangju
    Chen, Yongmei
    MATERIALS ENGINEERING AND MECHANICAL AUTOMATION, 2014, 442 : 125 - 128
  • [2] Lower Cervical Spine Motion Segment Computational Model Validation: Kinematic and Kinetic Response for Quasi-Static and Dynamic Loading
    Barker, Jeffrey B.
    Cronin, Duane S.
    Nightingale, Roger W.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (06):
  • [3] Testing and modelling of annealed float glass under quasi-static and dynamic loading
    Osnes, Karoline
    Borvik, Tore
    Hopperstad, Odd Sture
    ENGINEERING FRACTURE MECHANICS, 2018, 201 : 107 - 129
  • [4] Quasi-static and dynamic experiments of aluminum honeycombs under combined compression-shear loading
    Ashab, A. S. M.
    Ruan, Dong
    Lu, Guoxing
    Wong, Yat Choy
    MATERIALS & DESIGN, 2016, 97 : 183 - 194
  • [5] Axial compression behaviour of thin-walled metallic tubes under quasi-static and dynamic loading
    Tak, S. K.
    Iqbal, M. A.
    THIN-WALLED STRUCTURES, 2021, 159
  • [6] Quasi-static and dynamic testing of splitting, expansion and expansion splitting hybrid tubes under oblique loading
    Moreno, C.
    Beaumont, R.
    Hughes, D. J.
    Williams, T.
    Dashwood, R.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2017, 100 : 117 - 130
  • [7] TESTING OF A BIOMECHANICAL MODEL OF THE LUMBAR MUSCLE FORCE DISTRIBUTION USING QUASI-STATIC LOADING EXERCISES
    LADIN, Z
    NEFF, KM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1992, 114 (04): : 442 - 449
  • [8] Crashworthiness Performance of Multi-Cornered Structures under Quasi-Static Compression and Dynamic Axial Loading Conditions
    Tyan, Tau
    Aekbote, Krishnakanth
    Chen, Guofei
    Link, Todd M.
    SAE INTERNATIONAL JOURNAL OF MATERIALS AND MANUFACTURING, 2021, 14 (02) : 153 - 193
  • [9] Compression properties and failure mechanisms of laser additively repaired titanium alloys under quasi-static and dynamic loading
    Pang, Zhicong
    Cui, Luqing
    Cao, Zhenyang
    Hu, Shuang
    Zhao, Wang
    Liang, Xiaoqing
    Sun, Shan
    Yang, Hongwei
    Luo, Sihai
    He, Weifeng
    Cheng, Ronghui
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1010
  • [10] Anteroposterior shear stiffness of the upper thoracic spine at quasi-static and dynamic loading rates-An in vitro biomechanical study
    Yamamoto, Shun
    Dias, Luis
    Street, John
    Cripton, Peter A.
    Oxland, Thomas R.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2022, 40 (07) : 1687 - 1694