Second-generation MS-based high-throughput screening system for enantioselective catalysts and biocatalysts

被引:48
|
作者
Schrader, W
Eipper, A
Pugh, DJ
Reetz, MT
机构
[1] Max Planck Inst Kohlenforsch, D-45470 Mulheim, Germany
[2] Micromass UK Ltd, Manchester M22 5PP, Lancs, England
关键词
multiplexed ESI-MS; high-throughput screening; enantioselectivity; combinatorial catalysis; directed evolution;
D O I
10.1139/V02-069
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A high-throughput method is described, where the enantioselectivity of approximately 10 000 catalysts or biocatalysts can be determined per day. The method is based on electrospray mass spectrometric techniques using an eight-channel multiplexed (MUX) sprayer system connected to a time-of-flight mass spectrometer. The inlet of the ion source is controlled by a stepping rotor that is continuously moving from one sprayer to the next with a recording time of 100 ms for each channel and a delay time of 50 ms, thus allowing a spectrum to be obtained from each channel every 1.2 s. One cycle, where eight samples are being sprayed in parallel, requires around 70 s, which allows a 96-well microtiter plate to be screened in 14 min. Integration of two pseudo-enantiomers (S)-glycidyl phenyl ether and (R)-D-5-glycidyl phenyl ether is necessary to quantify the enantiomeric excess (ee-value), where one enantiomer is isotopically labeled to allow easy identification of the mass spectrometric signals. Errors of similar to2% for the ee-values indicate that in addition to the significant improvement in sample throughput this is also a precise method for high-throughput screening. This second-generation assay is useful for combinatorial enantioselective transition-metal catalysis and in the directed evolution of enantioselective enzymes.
引用
收藏
页码:626 / 632
页数:7
相关论文
共 50 条
  • [1] New methods for the high-throughput screening of enantioselective catalysts and biocatalysts
    Reetz, MT
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2002, 41 (08) : 1335 - 1338
  • [2] A practical NMR-based high-throughput assay for screening enantioselective catalysts and biocatalysts
    Reetz, MT
    Eipper, A
    Tielmann, P
    Mynott, R
    ADVANCED SYNTHESIS & CATALYSIS, 2002, 344 (09) : 1008 - 1016
  • [3] A method for high-throughput screening of enantioselective catalysts
    Reetz, MT
    Becker, MH
    Klein, HW
    Stöckigt, D
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 1999, 38 (12) : 1758 - 1761
  • [4] High-throughput screening of enantioselective catalysts by immunoassay
    Taran, F
    Gauchet, C
    Mohar, B
    Meunier, S
    Valleix, A
    Renard, PY
    Créminon, C
    Grassi, J
    Wagner, A
    Mioskowski, C
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2002, 41 (01) : 124 - 127
  • [5] High-throughput screening for biocatalysts
    Wahler, D
    Reymond, JL
    CURRENT OPINION IN BIOTECHNOLOGY, 2001, 12 (06) : 535 - 544
  • [6] A high-throughput screening protocol for fast evaluation of enantioselective catalysts
    Wolf, C
    Hawes, PA
    JOURNAL OF ORGANIC CHEMISTRY, 2002, 67 (08): : 2727 - 2729
  • [7] From stereodynamics to rapid high-throughput screening of enantioselective catalysts
    Trapp, Oliver
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [8] High-throughput MS-based protein phenotyping: Application to haptoglobin
    Tubbs, KA
    Kiernan, UA
    Niederkofler, EE
    Nedelkov, D
    Bieber, AL
    Nelson, RW
    PROTEOMICS, 2005, 5 (18) : 5002 - 5007
  • [9] High-throughput screening system for generation of fluorescent indicators
    Takikawa, Kenji
    Iinuma, Sho
    Namiki, Shigeyuki
    Sakamoto, Hirokazu
    Hirose, Kenzo
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2010, 112 : 232P - 232P
  • [10] High-throughput screening of MOF catalysts
    Palomba, Joseph
    Cohen, Seth
    Kalaj, Mark
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258