Investigation for the optimal thermohydraulic performance of artificially roughened solar air heaters

被引:179
|
作者
Verma, SK [1 ]
Prasad, BN
机构
[1] Dept Engn Mech, Dr BATU, Lonere, MS, India
[2] RIT, Dept Mech Engn, Jamshedpur, Bihar, India
关键词
D O I
10.1016/S0960-1481(99)00081-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Artificially roughened solar air heaters perform better than the plane ones under the same operating conditions. However, artificial roughness leads to even more fluid pressure thereby increasing the pumping power. Roughness and flow parameters viz. relative roughness pitch p/e, relative roughness height e/D and flow Reynolds number Re have a combined effect on the heat transfer as well as fluid pressure (friction factor). Investigation for the optimal thermohydraulic performance (i.e. maximum heat transfer for minimum friction loss) of artificially roughened solar air heaters has been carried out. An optimisation parameter known as roughness Reynolds number which combines the roughness and flow effect and is expressed as e(+) = e/D root f(r)/2 Re has been considered. Thermohydraulic performance has been defined by the equation n(thermo) = (St(r)/St(s))(3)/(f(r)/f(s)). It has been found that e(opt)(+) similar or equal to 24 gives the optimal thermohydraulic performance in such collectors and therefore the optimal thermohydraulic performance curves [3], for designing such collectors for practical applications are suitable. The Value of optimal thermohydraulic performance has been found to be about 71% corresponding to e(opt)(+) = 24. (C) 1999 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:19 / 36
页数:18
相关论文
共 50 条
  • [1] OPTIMAL THERMOHYDRAULIC PERFORMANCE OF ARTIFICIALLY ROUGHENED SOLAR AIR HEATERS
    PRASAD, BN
    SAINI, JS
    SOLAR ENERGY, 1991, 47 (02) : 91 - 96
  • [2] A review of thermohydraulic performance of artificially roughened solar air heaters
    Kumar, Anil
    Saini, R. P.
    Saini, J. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 37 : 100 - 122
  • [3] Thermal performance of artificially roughened solar air heaters
    Prasad, B. N.
    SOLAR ENERGY, 2013, 91 : 59 - 67
  • [4] Thermohydraulic performance of solar air heaters with roughened absorber plates
    Gupta, D
    Solanki, SC
    Saini, JS
    SOLAR ENERGY, 1997, 61 (01) : 33 - 42
  • [5] Performance of artificially roughened solar air heaters-A review
    Hans, Vishavjeet Singh
    Saini, R. P.
    Saini, J. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08): : 1854 - 1869
  • [6] Augmented artificially roughened solar air heaters
    Yadav, Anil Singh
    Agrawal, Abhay
    Sharma, Abhishek
    Sharma, Sachin
    Maithani, Rajesh
    Kumar, Anil
    MATERIALS TODAY-PROCEEDINGS, 2022, 63 : 226 - 239
  • [7] Evaluation of thermal performance factor for solar air heaters with artificially roughened channels
    Siddique, Waseem
    Raheem, Aneeq
    Aqeel, Muhammad
    Qayyum, Sualeh
    Salamen, Tareq
    Waheed, Khalid
    Qureshi, Kamran
    ARCHIVE OF MECHANICAL ENGINEERING, 2021, 68 (02) : 195 - 225
  • [8] Optimization of thermo hydraulic performance in three sides artificially roughened solar air heaters
    Prasad, B. N.
    Kumar, Ashwini
    Singh, K. D. P.
    SOLAR ENERGY, 2015, 111 : 313 - 319
  • [9] A Comprehensive Review on Roughness Geometries and Investigation Techniques Used in Artificially Roughened Solar Air Heaters
    Patil, A. K.
    Saini, J. S.
    Kumar, K.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (01): : 1 - 15
  • [10] Thermal analysis of three sides artificially roughened solar air heaters
    Behura, Arun Kumar
    Rout, Sachindra Kumar
    Pandya, Himanshu
    Kumar, Ashiwini
    INTERNATIONAL CONFERENCE ON RECENT ADVANCEMENT IN AIR CONDITIONING AND REFRIGERATION, RAAR 2016, 2017, 109 : 279 - 285