Enzymatic sensors based on the ISFETs for determination of heavy metal ions in some vegetables

被引:0
|
作者
Starodub, NF
Torbicz, W
Starodub, VM
Kanjuk, MI
Ternovoj, KS
机构
关键词
enzymosensors; pesticides; ISFET; heavy metals;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Enzymatic sensors based on the ion sensitive field effect transistor (ISFET) for detection of heavy metal ions were developed. It was shown that a urease sensor is more sensitive to above mentioned ions than cholinesterases (ChEs) sensor is. Inhibition of ChEs is reversible and their activity may be restored by the removing of metal ions from the membranes. ChEs are more stable than urease at the immobilization in the sensor membranes and in time of enzymatic membrane storage. The sensitivity of the urease sensor to heavy metal ions metals was found as follows: Hg2+>Cu2+>Cd2+>Co2+. The detection limit depends on the metal ion to be analysed. It was in the range of 10(-4)-10(-6) mol/l. To discriminate both, heavy metal ions and phospororganic pesticides in samples, it was necessary to use the system combined the urease and ChEs sensors. The use of easily replaceable enzymatic membranes from alginate gel or nitrocellulose (NC) is more suitable for repeated analysis than reactivation of these membranes. The standard deviation of sensor responses for different membrane castings did not exceed 10%. To prevent non-specific response (as a result of influence of medium conditions and inhibition of enzyme activity by vegetable sap), the analysed samples should be diluted 2-40 times by 5 mmol/l buffer solution, containing 140 mmol/l sodium chloride.
引用
收藏
页码:1383 / 1384
页数:2
相关论文
共 50 条
  • [1] Optical sensors for determination of heavy metal ions
    Oehme, I
    Wolfbeis, OS
    MIKROCHIMICA ACTA, 1997, 126 (3-4) : 177 - 192
  • [2] Optical sensors for determination of heavy metal ions
    Ines Oehme
    Otto S. Wolfbeis
    Microchimica Acta, 1997, 126 : 177 - 192
  • [3] Optical Sensors for Determination of Heavy Metal Ions
    Oehme, Ines
    Wolfbeis, Otto S.
    Mikrochimica Acta, 1997, 126 (03): : 177 - 192
  • [4] Antibody-based sensors for heavy metal ions
    Blake, DA
    Jones, RM
    Blake, RC
    Pavlov, AR
    Darwish, IA
    Yu, HN
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12): : 799 - 809
  • [5] Selective determination of heavy metal ions with sensors coupled to immobilised enzymes
    Soldatkin, AP
    Korpan, YI
    Zhylyak, GA
    Martelet, C
    El'Skaya, AV
    BIOSENSORS FOR DIRECT MONITORING OF ENVIRONMENTAL POLLUTANTS IN FIELD, 1997, 38 : 281 - 288
  • [6] Progress on sensors based on nanomaterials for rapid detection of heavy metal ions
    Yuan Liu
    Yan Deng
    Hongming Dong
    Keke Liu
    Nongyue He
    Science China(Chemistry), 2017, (03) : 329 - 337
  • [7] Progress on sensors based on nanomaterials for rapid detection of heavy metal ions
    Yuan Liu
    Yan Deng
    Hongming Dong
    Keke Liu
    Nongyue He
    Science China(Chemistry), 2017, 60 (03) : 329 - 337
  • [8] Two-dimensional nanomaterial based sensors for heavy metal ions
    Gan, Xiaorong
    Zhao, Huimin
    Schirhagl, Romana
    Quan, Xie
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [9] Two-dimensional nanomaterial based sensors for heavy metal ions
    Xiaorong Gan
    Huimin Zhao
    Romana Schirhagl
    Xie Quan
    Microchimica Acta, 2018, 185
  • [10] Progress on sensors based on nanomaterials for rapid detection of heavy metal ions
    Yuan Liu
    Yan Deng
    Hongming Dong
    Keke Liu
    Nongyue He
    Science China Chemistry, 2017, 60 : 329 - 337