A simple UV irradiator for low dose reassessment with LiF TLD-100

被引:25
|
作者
Delgado, A
Unamuno, V
Muniz, JL
Correcher, V
Ros, JMG
机构
[1] CIEMAT-IMA, 28040 Madrid
关键词
D O I
10.1093/oxfordjournals.rpd.a031834
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and efficient UV irradiator specifically designed for dose reassessment by phototransferred thermo-luminescence is described. The instrument permits the automatic irradiation of loose TLD chips for a preselected time and at a controlled temperature. The good phototransference characteristics allow the efficient reassessment of absorbed doses of the order of 0.2 mGy with good measurement performance, well within the limits required for personnel dosimetry.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 50 条
  • [1] RADIATION DAMAGE IN LIF (TLD-100)
    DOPPKE, KP
    CAMERON, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 624 - &
  • [2] ABSENCE OF FADING IN LIF (TLD-100)
    SUNTHARALINGAM, N
    CAMERON, JR
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (04): : 624 - +
  • [3] Absorbed dose evaluation of a blood irradiator with alanine, TLD-100 and ionization chamber
    Grasso, S.
    Varallo, A.
    Ricciardi, R.
    Italiano, M. E.
    Oliviero, C.
    D'Avino, V.
    Feoli, C.
    Ambrosino, F.
    Pugliese, M.
    Clemente, S.
    APPLIED RADIATION AND ISOTOPES, 2023, 200
  • [4] THERMOLUMINESCENCE OF LIF TLD-100 BY PHOTOTRANSFER
    SUNTA, CM
    WATANABE, S
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1976, 9 (08) : 1271 - &
  • [5] TRAPPING CENTERS IN LIF TLD-100
    MOHARIL, SV
    SOLID STATE COMMUNICATIONS, 1980, 33 (06) : 697 - 700
  • [6] Dose and Range Perturbation by LiF TLD-100 in Proton Beam Therapy
    Jin, H.
    Su, Z.
    Slopsema, R.
    Li, Z.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] On the reassessment of thermal neutron doses in TLD-100 by measuring the residual dose
    Abraham, A.
    Weinstein, M.
    German, U.
    Alfassi, Z. B.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 524 - 527
  • [8] EFFECTS OF TOTAL DOSE ON ENERGY DEPENDENCE OF TLD-100 LIF DOSIMETERS
    HENDEE, WR
    IBBOTT, GS
    GILBERT, DB
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1968, 19 (05): : 431 - &
  • [9] THERMOLUMINESCENCE OF LIF TLD-100 DOSIMETER CRYSTALS
    FAIRCHILD, RG
    MATTERN, PL
    LENGWEILER, K
    LEVY, PW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (06) : 366 - 372
  • [10] EFFECT OF ANNEALING ON THERMOLUMINESCENCE OF LIF (TLD-100)
    JAIN, VK
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1976, 38 (01): : K65 - K68