Experimental investigation of annular two-phase flow splitting at a microimpacting T-junction

被引:14
|
作者
Chen, Jinfang [1 ]
Wang, Shuangfeng [1 ,2 ]
Ke, Hongfeng [1 ]
Zhou, Mi [1 ]
Li, Xuanyou [2 ]
机构
[1] S China Univ Technol, Sch Chem & Chem Engn, Key Lab Enhanced Heat Transfer & Energy Conservat, Minist Educ, Guangzhou 510640, Guangdong, Peoples R China
[2] Shandong Acad Sci, Ind Energy Conservat Ctr, Jinan 250013, Peoples R China
基金
中国国家自然科学基金;
关键词
Phase split; Annular two-phase flow; Microimpacting T-junction; Surface tension; Viscous force; IMPACTING TEE JUNCTION; GAS-LIQUID FLOW; PHASE-SEPARATION; SURFACE-TENSION; PRESSURE-DROP; HEAT-TRANSFER; MICROCHANNEL NETS; DIAMETER; PATTERNS;
D O I
10.1016/j.ces.2014.07.018
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
An experimental study was conducted in order to investigate the phase split of annular two-phase flow at a horizontal microimpacting T-junction with the square cross section of 0.5 x 0.5 mm(2). A high speed record camera was used to help elucidate the fluid dynamics at the junction. Nitrogen and water at 120 kPa (abs) and room temperature of 22 degrees C were used as the test fluids. The inlet superficial velocities of gas and liquid varied from 13 to 30 m/s and from 0.018 to 0.08 m/s, respectively, covering a wide range of the inlet qualities between 0.23 and 0.58. The aqueous solutions of sodium dodecysulfate (SDS) and carboxymethyl cellulose (CMC) with different mass concentrations were employed to study the effect of surface tension and viscous force on phase split, respectively. Experimental results showed that, the phase split of annular flow at microimpacting T-junctions was less affected by either the inlet phase superficial velocities or the viscous force, but varied largely with surface tension. Besides, the phase maldistribution of annular flow was smaller than that of slug flow and slug-annular flow at microimpacting T-junctions. Furthermore, when the present data were compared to those of mini- and macro-sized junctions at similar flow conditions, it was found that the phase maldistribution at microimpacting T-junctions was the smallest. Finally, good agreement was obtained between the present experimental data and a modification of an existing model. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:154 / 163
页数:10
相关论文
共 50 条
  • [1] Experimental investigation of two-phase slug flow splitting at a micro impacting T-junction
    Chen, Jinfang
    Wang, Shuangfeng
    Zhang, Xinqiang
    Ke, Hongfeng
    Li, Xuanyou
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 939 - 948
  • [2] The split of annular two-phase flow at a small diameter T-junction
    Stacey, T
    Azzopardi, BJ
    Conte, G
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2000, 26 (05) : 845 - 856
  • [3] Fluctuation characteristics of two-phase flow splitting at a vertical impacting T-junction
    Wang, SF
    Shoji, M
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2002, 28 (12) : 2007 - 2016
  • [4] Two-phase stratified flow splitting at a T-junction with an inclined branch arm
    Penmatcha, VR
    Ashton, PJ
    Shoham, O
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (06) : 1105 - 1122
  • [5] Two-phase stratified flow splitting at a T-junction with an inclined branch arm
    Petroleum Eng Dept, Univ of Tulsa, Tulsa OK 74104-3189, United States
    Int J Multiphase Flow, 6 (1105-1122):
  • [6] Experimental investigation on the effect of diameter ratio on two-phase slug flow separation in a T-Junction
    Saieed, Ahmed
    Pao, William
    Hewakandamby, Buddhika
    Azzopardi, Barry J.
    Wood, David A.
    Ali, Hafiz M.
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2018, 170 : 139 - 150
  • [7] Experimental investigation of two-phase separation in T-Junction with combined diameter ratio
    Memon, Zeeshan Qadir
    Pao, William
    Hashim, Fakhruldin M.
    Ali, Hafiz M.
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2020, 73
  • [8] Numerical Study and Experimental Comparison of Two-Phase Flow Generation in a T-Junction
    Arias, S.
    Montlaur, A.
    AIAA JOURNAL, 2017, 55 (05) : 1565 - 1574
  • [9] Two-phase flow distribution of refrigerants through a T-junction
    Tae, Sang-Jin
    Cho, Keumnam
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 775 - +
  • [10] Experimental investigation of two-phase separation in a horizontal T-junction with vertical branch arm
    Memon, Z. Q.
    Pao, W.
    Hashim, F.
    Ahmed, S.