A time- and position-sensitive detector using a resistive film anode combined with a "modified backgammon with weighted capacitors" readout pad

被引:6
|
作者
Veshapidze, G
Nishide, T
Shiromaru, H
Kobayashi, N
Mizogawa, T
机构
[1] Tokyo Metropolitan Univ, Fac Sci, Hachioji, Tokyo 1920397, Japan
[2] Wakayama Natl Coll Technol, Wakayama 6440023, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 2002年 / 41卷 / 2A期
关键词
position-sensitive detector; MBWC; TOF; multihit; resistive film; wedge-and-strip;
D O I
10.1143/JJAP.41.871
中图分类号
O59 [应用物理学];
学科分类号
摘要
A new time- and position-sensitive detector (PSD) was constructed by combining a microchannel plate (MCP) and a resistive-film anode with a readout pad based on the "modified backgammon technique with weighted capacitors" (MBWC). By using a resistive film, the free-flight length of the electron avalanche formed by the MCP is much shorter than in a conventional PSD with an MBWC anode. Consequently, the PSD is more compact, which presents several practical advantages. Temporal and positional resolution and imaging linearity were examined by measuring a mask image.
引用
收藏
页码:871 / 875
页数:5
相关论文
共 21 条
  • [2] A two-dimensional position-sensitive ion detector based on modified backgammon method with weighted-coupling capacitors
    Mizogawa, T
    Shiromaru, H
    Sato, M
    Ito, Y
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) : 141 - 149
  • [3] A POSITION-SENSITIVE MICROCHANNELPLATE DETECTOR USING A DELAY-LINE READOUT ANODE
    KELLER, H
    KLINGELHOFER, G
    KANKELEIT, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (02): : 221 - 224
  • [4] A resistive-anode based position-sensitive Rydberg atom detector
    Jones, A. C. L.
    Moxom, J.
    Fuentes-Garcia, M.
    Cecchini, G. G.
    Membreno, E. E.
    Roeder, E. E.
    Mills Jr, A. P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (01):
  • [5] Multi-hit, position-sensitive, time-of-flight spectrometry using a modified-backgammon-weighed-capacitor anode
    Rajgara, FA
    Mathur, D
    Nishide, T
    Kitamura, T
    Shiromaru, H
    Achiba, Y
    Kobayashi, N
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) : 151 - 162
  • [6] Position-sensitive hybrid particle detector based on discrete-time readout
    Masoliver, Pavel
    Abusleme, Angel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1061
  • [7] A position-sensitive alpha detector using a thin plastic scintillator combined with a position-sensitive photomultiplier tube
    Yamamoto, S
    Iida, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (2-3): : 387 - 393
  • [8] POSITION-SENSITIVE GAMMA-RAY DETECTORS USING RESISTIVE CHARGE DIVISION READOUT
    GERBER, MS
    MILLER, DW
    SCHLOSSER, PA
    STEIDLEY, JW
    DEUTCHMAN, AH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 182 - 187
  • [9] Using time- and position-sensitive detection for the study of intramolecular dynamics.
    van der Zande, WJ
    Peverall, R
    Thomas, R
    Rosén, S
    Larsson, M
    Bobbenkamp, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U322 - U323
  • [10] Circular one-dimensional position-sensitive time-of-flight microchannel plate detector using resistive anode for space plasma measurements
    Yokota, Shoichiro
    Saito, Yoshifumi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (01):