NEUTRON FLUX MEASUREMENTS FOR THE PBMR DPP

被引:0
|
作者
Procter, Gordon [1 ]
Artaud, Clark J. [2 ]
机构
[1] Pebble Bed Modular Reactor Proprietary Ltd, Design Engineer Nucl Instrumentat, ZA-0046 Centurion, South Africa
[2] Global Commerc Nuclear Thermo Fisher Sci Process, San Diego, CA 92121 USA
来源
PROCEEDINGS OF THE 4TH INTERNATIONAL TOPICAL MEETING ON HIGH TEMPERATURE REACTOR TECHNOLOGY, VOL 1 | 2009年
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
For the Pebble Bed Modular Reactor (PBMR) Demonstration Power Plant (DPP) several neutron flux measurements are made, both within the Reactor Pressure Vessel (RPV) and outside the RPV. The measurements within the RPV are performed by the Core Structures Instrumentation (CSI) system. While those outside the RPV are performed by the Nuclear Instrumentation System (NIS). The PBMR has a long annular core with a relative low power density, requiring flux monitoring over the full 11 M of the active core region. The core structures instrumentation measures the neutron flux in the graphite reflector. Two measurement techniques are used; Fission Chamber based channels with high sensitivity for initial fuel load and low power testing and SPND channels for measurements at full and near full power operation. The CSI flux monitoring supports data acquisition for design Verification and Validation (V&V), and the data will also be used for the characterization of the NIS for normal reactor start-ups and low power operation. The CSI flux measurement channels are only required for the first few years of operation; the sensors are not replaceable. The Nuclear Instrumentation System is an ex core system that includes the Post Event Instrumentation. Due to the long length of the PBMR core, the flux is measured at several axial positions. This is a fission chamber based system; full advantage is taken of all the operating modes for fission chambers (pulse counting, mean square voltage (MSV), and linear current). The CSI flux monitoring channels have many technical and integration challenges. The environment where the sensors and their associated signal cables are required to operate is extremely harsh; temperature and radiation levels are very high. The selection and protection of the fission chambers warranted special attention. The selection criteria for sensors and cables takes cognizance of the fact that the assemblies are built in during the assembly of the reactor internal structures, and that they are not replaceable. This paper describes the challenges in the development of the monitoring systems for the measurement of neutron flux both within the RPV and the ex core region. The selection of detector configuration and the associated signal processing will be discussed. The use of only analogue signal processing techniques will also be elaborated on.
引用
收藏
页码:25 / +
页数:2
相关论文
共 50 条
  • [1] NEUTRON FLUX MEASUREMENTS WITH COBALT
    EASTWOOD, TA
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1966, 17 (01): : 17 - &
  • [2] NEUTRON FLUX AND ENERGY MEASUREMENTS
    DENNIS, JA
    PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 1 - &
  • [3] NEUTRON FLUX MEASUREMENTS WITH THERMOPILES
    LAPSLEY, AC
    NUCLEONICS, 1953, 11 (05): : 62 - 64
  • [4] ATMOSPHERIC NEUTRON FLUX MEASUREMENTS
    GAUGER, J
    JOURNAL OF GEOPHYSICAL RESEARCH, 1964, 69 (11): : 2209 - +
  • [5] Investigation on the effects of internal reflector size on the neutron flux of PBMR reactors by means of MCNP code
    Daryabak, A. (Arash.daryabak@hotmail.com), 1600, Inderscience Enterprises Ltd., 29, route de Pre-Bois, Case Postale 856, CH-1215 Geneva 15, CH-1215, Switzerland (08):
  • [6] Semiconductor detectors for neutron flux measurements
    Litovchenko, PG
    Wahl, W
    Bisello, D
    Candelori, A
    Litovchenko, AP
    Lastovetsky, VF
    Barabash, LI
    Kibkalo, TI
    Polivtsev, LA
    Wyss, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 423 - 425
  • [7] Reliability Assurance of Neutron Flux Measurements
    Dreyzin, V. E.
    Logvinov, D., I
    Grimov, A. A.
    Varganov, V. V.
    MEASUREMENT TECHNIQUES, 2021, 64 (05) : 405 - 413
  • [8] Reliability Assurance of Neutron Flux Measurements
    V. E. Dreyzin
    D. I. Logvinov
    A. A Grimov
    V. V. Varganov
    Measurement Techniques, 2021, 64 : 405 - 413
  • [9] PROTON RECOIL MONITOR FOR NEUTRON FLUX MEASUREMENTS
    JASZCZAK, RJ
    MACKLIN, RL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (02): : 240 - &
  • [10] OPTIMUM DIAMETER OF WIRES FOR NEUTRON FLUX MEASUREMENTS
    SEGAL, Y
    VELNER, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (02): : 763 - &