Distortion Correction Method In the High-precision and High-speed CCD Measurement System

被引:0
|
作者
Li Jing [1 ]
Wang Junzheng [1 ]
Hao Renjian [1 ]
机构
[1] Beijing Inst Technol, Sch Automat, Key Lab Complex Syst Intelligent Control & Decis, Beijing 100081, Peoples R China
关键词
CCD image; Distortion correction; Data fitting; Perspective transformation; WIDE-ANGLE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the high-precision and high-speed measurement system, the distortion of CCD pixes will give a greater margin of error to measurement results. According to the characteristic of noise leading to the image distortion, this article establishes the image transformation model. Data fitting based method is used for correcting image distortion. For the distortion caused by camera installation, the perspective transformation is used to correcting the image. And then the four points calibration method is adopted to calibrating the measurement system. Experiments adopt the high speed area array CCD to gather images with the circular facula in the target area launched by the laser, and calculate the real position of the facula in the target area, adopt the high accurate displacement sensor to give the true displacement of the target which is used to verify the real position of the facula in the target area. The results show that the algorithm can reduce the influence of image distortion, which advances the measurement accuracy efficiently.
引用
收藏
页码:3613 / 3616
页数:4
相关论文
共 5 条
  • [1] Camera lens radial distortion correction using two-view projective invariants
    Du, Xin
    Li, Hongdong
    Zhu, Yunfang
    [J]. OPTICS LETTERS, 2011, 36 (24) : 4734 - 4736
  • [2] Distortion correction for a wide-angle on real-time lens based digital image processing
    Jiang, J
    Zhang, GJ
    Zhou, FQ
    Yu, DY
    Xie, HB
    Liu, H
    [J]. OPTICAL ENGINEERING, 2003, 42 (07) : 2029 - 2039
  • [3] Nonuniformity Correction and Calibration Method in the High-precision CCD Measurement and Servo Control System
    Li, Jing
    Wang, Junzheng
    Zhou, Bin
    Shen, Wei
    [J]. PROCEEDINGS OF THE 48TH IEEE CONFERENCE ON DECISION AND CONTROL, 2009 HELD JOINTLY WITH THE 2009 28TH CHINESE CONTROL CONFERENCE (CDC/CCC 2009), 2009, : 8446 - 8451
  • [4] A New Solution for Camera Calibration and Real-Time Image Distortion Correction in Medical Endoscopy-Initial Technical Evaluation (vol 59, pg 634, 2012)
    Melo, Rui
    Barreto, Joao P.
    Falcao, Gabriel
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (07) : 2095 - 2095
  • [5] A pipelined architecture for real-time correction of barrel distortion in wide-angle camera images
    Ngo, HT
    Asari, VK
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2005, 15 (03) : 436 - 444