Performance of the CMS ECAL data acquisition system at LHC Run II

被引:0
|
作者
Wamorkar, Tanvi [1 ]
机构
[1] Northeastern Univ, Boston, MA 02115 USA
基金
英国科学技术设施理事会;
关键词
Front end; Trigger; DAQ; Data management;
D O I
10.1016/j.nima.2018.12.084
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
During 2017, the Large Hadron Collider provided proton-proton collisions up to an integrated luminosity of 50/fb and the Compact Muon Solenoid (CMS) experiment was able to record 90.3% of this data. The electromagnetic calorimeter (ECAL) of CMS was able to achieve excellent data collection efficiency owing to its reliable data acquisition (DAQ) system. The modular and scalar schema followed by the ECAL DAQ system means that ECAL crystals are divided in sectors, each of which is controlled by three interconnected boards. A multi-machine distributed software configures the electronic boards and follows the life cycle of the acquisition process. The increase in instantaneous luminosity during Run II has resulted in an increase in the number of occasional errors due to radiation effects. To combat this, ECAL DAQ has been equipped with automatic recovery procedures and monitoring services.
引用
收藏
页码:346 / 348
页数:3
相关论文
共 50 条
  • [1] CMS ECAL monitoring and calibration in LHC Run II
    Mudholkar, Tanmay
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [2] Precision crystal calorimetry in LHC Run II with the CMS ECAL
    Brianza, L.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [3] Performance of CMS ECAL with first LHC data
    Franzoni, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 90 - 94
  • [4] The performance of the CMS ECAL Preshower detector at LHC
    Liu, Zong-Kai
    Kuo, Chia-Ming
    Li, Syue-Wei
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,
  • [5] CMS tracker performance and readiness for LHC Run II
    Viliani, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 824 : 67 - 69
  • [6] Overview of the CMS detector performance in LHC run II
    Borrello, L.
    5TH INTERNATIONAL CONFERENCE ON NEW FRONTIERS IN PHYSICS, 2017, 164
  • [7] Performance of the CMS electromagnetic calorimeter in the LHC Run II
    Bartosik, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 139 - 140
  • [8] The data acquisition system for the CMS experiment at the LHC
    Antchev, G
    Berti, L
    Cano, E
    Cittolin, S
    Erhan, S
    Gigi, D
    Gutleber, J
    Jacobs, C
    Maron, G
    Meijers, F
    Meschi, E
    Ninane, A
    Orsini, L
    Oh, A
    Pollet, L
    Racz, A
    Samyn, D
    Scharff-Hansen, P
    Schwick, C
    Sphicas, P
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 540 - 549
  • [9] Performance of the CMS electromagnetic calorimeter during the LHC Run II
    Zghiche, Amina
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [10] The data-acquisition system of the CMS experiment at the LHC
    Bauer, G.
    Beccati, B.
    Behrens, U.
    Biery, K.
    Bouffet, O.
    Branson, J.
    Bukowiec, S.
    Cano, E.
    Cheung, H.
    Ciganek, M.
    Cittolin, S.
    Coarasa, J. A.
    Deldicque, C.
    Dupont, A.
    Erhan, S.
    Gigi, D.
    Glege, F.
    Gomez-Reino, R.
    Hatton, D.
    Holzner, A.
    Hwong, Y. L.
    Masetti, L.
    Meijers, F.
    Meschi, E.
    Mommsen, R. K.
    Moser, R.
    O'Dell, V.
    Orsini, L.
    Paus, C.
    Petrucci, A.
    Pieri, M.
    Racz, A.
    Raginel, O.
    Sakulin, H.
    Sani, M.
    Schieferdecker, P.
    Schwick, C.
    Shpakov, D.
    Simon, M.
    Sumorok, K.
    INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2010), 2011, 331